MSMinuk Seung

Minuk Seung

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Minuk Seung has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Observation of fast Alfvén wave in KAERI plasma beam irradiation facility using an applied-field MPD thruster

    by Kil-Byoung Chai, Changmin Shin, Young Dae Yoon, Minuk Seung, Inyong Kwon

    Electromagnetic fluctuations between 300 and 500 kHz were observed in both ion saturation current and magnetic field measurements in the KAERI plasma beam irradiation facility where the applied-field magnetoplasmadynamic (MPD) thruster is used as a plasma source. In this study, the plasmas were ignited with deuterium gas and the plasma current (input power) was varied from 55 A (2 kW) to 155 A (6 kW). The electron temperature and density measured downstream of the MPD thruster plasma were ∼5 eV and (2–4) × 1012 cm−3, respectively. To identify the fluctuations, the dispersion relation and the phase velocity were experimentally obtained using the Beall method and were compared to the theoretical values under warm plasma conditions. It was revealed that the observed fluctuations were fast Alfvén waves with a circularly polarized magnetic field. In addition to the fast Alfvén waves, we also observed electrostatic fluctuations at a higher frequency that was similar to the lower-hybrid frequency.


  • In-Core Neutron Detection System Using a Dual-Mode Self-Reset Preamplifier With the Micro-Pocket Fission Detector

    by Minuk Seung, Duckhyun Kim, Dongseong Shin, Troy C. Unruh, Kevin Tsai, Woo-Young Choi, Inyong Kwon

    This article presents the development of an in-core neutron detector readout system utilizing a charge-sensitive amplifier (CSA) with a self-reset technique, alongside data loggers, to measure the output of the CSA. Micro-pocket fission detectors (MPFDs) were developed as in-vessel neutron detectors having many advantages in terms of portability size, reproducibility of charge deposition, usability in high neutron flux, and capability of gamma-ray discrimination. The proposed readout system for MPFDs can be operated in a dual mode which consists of integration and single event modes. The integration mode can count the number of saturated preamplifier outputs in a high-radiation environment. On the other hand, the single event mode can directly measure the analog data induced by detectors. A novel approach to dead time compensation is also introduced using an active dead time control (ADTC) method. This article shows the reactor transient test results conducted at the Transient REActor Test (TREAT) reactor. The neutron flux of 7 × 10 15 n/cm 2 · s with the full-width half maximum (FWHM) of 126 ms at the reactor power of 2.1 GWth was measured. According to the reactor power of 5.1 GWth, the neutron flux, and FWHM were obtained as 1.24 × 10 16 n/cm 2 · s and 136 ms, respectively.


  • Open Access

    Radiation-hardened-by-design preamplifier with binary weighted current source for radiation detector

    by Minuk Seung, Jong-Gyun Choi, Woo-Young Choi, Inyong Kwon


  • Cold Junction Compensation Technique of Thermocouple Thermometer Using Radiation-Hardened-by-Design Voltage Reference for Harsh Radiation Environment

    by Minuk Seung, Wooyoung Choi, Seop Hur, Inyong Kwon

    This article introduces a radiation-hardened-by-design (RHBD) cold junction compensation (CJC) circuit to compensate for the voltage variation at the cold junction of a thermocouple used in a nuclear power plant (NPP) to detect the reactor temperature. The key idea of the RHBD circuit is to cancel the error induced by radiation, subtracting two reference voltages. In this design, two conditions should be satisfied to realize the first-order cancellation. First, the two voltages should have similar changes according to temperature and radiation. Therefore, two identical voltage generators are used in the proposed circuit. Second, the two reference voltages might have different values. The proposed circuit was fabricated using general purpose 0.18- $\mu \text{m}$ complementary metal–oxide–semiconductor (CMOS) technology with a shallow trench isolation (STI) process. The RHBD CJC circuit showed a reference voltage of 275 mV at room temperature. The final output voltage variation was 5.2 mV under irradiation up to 2 Mrad, and the temperature coefficient (TC) was 2.9 ppm/°C in a range of 20 °–110 °C without additional trimming and annealing. The proposed circuit showed improvements of 60% and 90% for the radiation effect and temperature variation, respectively, compared with the conventional reference circuit. The active area and power consumption were 0.035 mm2 and 1.716 mW, respectively.