Anouk S. Verschuur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anouk S. Verschuur has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
Alexander Leemans
Image Sciences Institute, University Medical Center Utrecht
5 shared publicationsMartijn F. Boomsma
Department of Radiology, Isala Hospital
5 shared publicationsChantal M.W. Tax
Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands
4 shared publicationsChantal M. W. Tax
Image Sciences Institute, University Medical Center Utrecht
3 shared publicationsGerda van Wezel-Meijler
Department of Neonatology, Isala Women and Children's Hospital, Dokter van Heesweg 2, 8025 AB Zwolle, The Netherlands
3 shared publicationsIngrid M. Nijholt
Department of Radiology, Isala Hospital
3 shared publications
Latest Publications
- Open Access
- 29 June 2026
- Published by Frontiers Media SA in Frontiers in Radiology
- Vol. 6, 1868602
Harmonization of slice thickness through resampling improves comparability of MRI-derived neonatal brain volumes
Purpose: To assess reliability and agreement of brain volume measurements from neonatal T2-weighted magnetic resonance imaging (MRI) scans acquired with different slice thickness settings (i.e., 2 mm, 3 mm and 3 mm resampled). Methods: We used term-equivalent (38–45 weeks postmenstrual age) T2-weighted MRI scans with slice thicknesses of 2 mm and 3 mm from a subset of 40 preterm and term infants (27–40 weeks' gestation) from two existing neonatal imaging cohorts. Resampling of the 2 mm scans to a 3 mm grid provided a third set of scans, referred to as “3 mm resampled”. Automated brain segmentation provided intracranial volume, total brain volume, and volumes for eight brain structures. Reliability and agreement of volume measurements were assessed using intraclass correlation coefficients (ICC) and Bland-Altman plots, respectively. Results: For all volumes, inter-scan reliability was higher for 3 mm vs. 3 mm resampled scans (mean observer ICC >0.92) compared to 2 mm vs. 3 mm scans (mean observer ICC >0.87). Bland-Altman plots revealed smaller mean volume differences between 3 mm and 3 mm resampled scans than between 2 mm and 3 mm scans. However, a proportional bias was found for deep gray matter volume for 3 mm vs. 3 mm resampled scans. Conclusion: Slice thickness influences brain volume measurements from neonatal MRI. Harmonization of imaging data acquired with different settings through image resampling improves reliability and agreement of brain volume measurements.
- 29 June 2026
- Published by Frontiers Media SA in Frontiers in Radiology
- Vol. 6, 1868602
Open AccessHarmonization of slice thickness through resampling improves comparability of MRI-derived neonatal brain volumes
Purpose: To assess reliability and agreement of brain volume measurements from neonatal T2-weighted magnetic resonance imaging (MRI) scans acquired with different slice thickness settings (i.e., 2 mm, 3 mm and 3 mm resampled). Methods: We used term-equivalent (38–45 weeks postmenstrual age) T2-weighted MRI scans with slice thicknesses of 2 mm and 3 mm from a subset of 40 preterm and term infants (27–40 weeks' gestation) from two existing neonatal imaging cohorts. Resampling of the 2 mm scans to a 3 mm grid provided a third set of scans, referred to as “3 mm resampled”. Automated brain segmentation provided intracranial volume, total brain volume, and volumes for eight brain structures. Reliability and agreement of volume measurements were assessed using intraclass correlation coefficients (ICC) and Bland-Altman plots, respectively. Results: For all volumes, inter-scan reliability was higher for 3 mm vs. 3 mm resampled scans (mean observer ICC >0.92) compared to 2 mm vs. 3 mm scans (mean observer ICC >0.87). Bland-Altman plots revealed smaller mean volume differences between 3 mm and 3 mm resampled scans than between 2 mm and 3 mm scans. However, a proportional bias was found for deep gray matter volume for 3 mm vs. 3 mm resampled scans. Conclusion: Slice thickness influences brain volume measurements from neonatal MRI. Harmonization of imaging data acquired with different settings through image resampling improves reliability and agreement of brain volume measurements.
- Open Access
Automated Segmentation of Intracranial Arteries on 4D Flow MRI for Hemodynamic Quantification
Accurate vessel segmentation is essential for reliable hemodynamic quantification in 4D Flow MRI. Automated segmentation with deep learning offers a promising alternative to the time-consuming, operator-dependent manual segmentation, but its application is often hindered by the scarcity of labeled datasets. Moreover, while a previous study has evaluated the impact of automated vs manual segmentation on downstream intracranial hemodynamic quantification, it remains to be explored whether variability between different automated segmentation methods affects hemodynamic quantification significantly, particularly in the context of intracranial 7T 4D Flow MRI. We investigated a transfer learning–based intracranial artery segmentation model using a 3D full-resolution nnU-Net, pretrained on 355 TOF-MRA scans and fine-tuned on 11 7T 4D Flow MRI scans. The model was compared with two published models: a direct-transfer U-Net pretrained only on TOF-MRA without 4D Flow MRI fine-tuning, and a DenseNet U-Net trained from scratch on the same 11 7T 4D Flow MRI scans. Segmentation performance was evaluated against the manual reference on test sets with different resolutions and the impact on downstream hemodynamic quantification was assessed. The transfer learning–based nnU-Net achieved the highest Dice score (>0.85), the lowest HD95 (∼3 mm), and the highest ICCs in cross-sectional area (0.62–0.87, except PCAs) and mean blood flow (0.78– 0.98). For wall shear stress (WSS) quantification, the transfer learning–based nnU-Net segmentations achieved the closest agreement with the manual reference (mean = 1.57 ± 0.63 Pa, ICC = 0.96; max = 2.16 ± 1.05 Pa, ICC = 0.97) and minimal bias (≤ 1.7%), whereas U-Net and DenseNet U-Net showed systematic under-(−5%) and overestimation (+7%), respectively. However, several vessel segments, including the ACA for DenseNet U-Net and the BA for U-Net, showed statistically significant differences (ANOVA post-hoc correction P < 0.05) in the flow-related metrics when compared with the manual reference. These results suggest that a transfer learning–based nnU-Net can provide accurate automated intracranial artery segmentation for 7T 4D Flow MRI. Differences among automated segmentation pipelines and associated analysis regions were linked to differences in downstream hemodynamic estimates.
Open AccessAutomated Segmentation of Intracranial Arteries on 4D Flow MRI for Hemodynamic Quantification
Accurate vessel segmentation is essential for reliable hemodynamic quantification in 4D Flow MRI. Automated segmentation with deep learning offers a promising alternative to the time-consuming, operator-dependent manual segmentation, but its application is often hindered by the scarcity of labeled datasets. Moreover, while a previous study has evaluated the impact of automated vs manual segmentation on downstream intracranial hemodynamic quantification, it remains to be explored whether variability between different automated segmentation methods affects hemodynamic quantification significantly, particularly in the context of intracranial 7T 4D Flow MRI. We investigated a transfer learning–based intracranial artery segmentation model using a 3D full-resolution nnU-Net, pretrained on 355 TOF-MRA scans and fine-tuned on 11 7T 4D Flow MRI scans. The model was compared with two published models: a direct-transfer U-Net pretrained only on TOF-MRA without 4D Flow MRI fine-tuning, and a DenseNet U-Net trained from scratch on the same 11 7T 4D Flow MRI scans. Segmentation performance was evaluated against the manual reference on test sets with different resolutions and the impact on downstream hemodynamic quantification was assessed. The transfer learning–based nnU-Net achieved the highest Dice score (>0.85), the lowest HD95 (∼3 mm), and the highest ICCs in cross-sectional area (0.62–0.87, except PCAs) and mean blood flow (0.78– 0.98). For wall shear stress (WSS) quantification, the transfer learning–based nnU-Net segmentations achieved the closest agreement with the manual reference (mean = 1.57 ± 0.63 Pa, ICC = 0.96; max = 2.16 ± 1.05 Pa, ICC = 0.97) and minimal bias (≤ 1.7%), whereas U-Net and DenseNet U-Net showed systematic under-(−5%) and overestimation (+7%), respectively. However, several vessel segments, including the ACA for DenseNet U-Net and the BA for U-Net, showed statistically significant differences (ANOVA post-hoc correction P < 0.05) in the flow-related metrics when compared with the manual reference. These results suggest that a transfer learning–based nnU-Net can provide accurate automated intracranial artery segmentation for 7T 4D Flow MRI. Differences among automated segmentation pipelines and associated analysis regions were linked to differences in downstream hemodynamic estimates.
- 14 February 2026
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 47 (8) , ajnr.A9231-2138
Towards improved decision making of unruptured intracranial aneurysms using automated segmentation from MRA-TOF with iterative pseudo labeling
To enable accurate 3D morphological assessment and support clinical decision making, DIVA-seg: a Deep learning-based method for Intracranial Vessel and Aneurysm segmentation from MRA-TOF using a pseudo labeling approach was developed and validated. Three MRA-TOF datasets were used: 1) labeled data for training (n=57) and testing (n=14), 2) unlabeled data for pseudo labels (n=518), and 3) labeled data for external validation (n=82). An nnU-Net (Model 1) was iteratively trained for creating pseudo labels for Dataset 2. Cases with stable segmentation performance across iterations were selected for further training. Stable cases (n=484) were combined with Dataset 1 to train a second nnU-Net (Model 2). Performance testing on Dataset 1 and 3 comprised of Dice similarity coefficients (DSC), 95%-Hausdorff distances, 3D morphological measures, and a blinded qualitative evaluation. DIVA-seg achieved a mean (standard deviation) internal vessel and aneurysm DSC of 0.925 (±0.025) and 0.880 (±0.045), respectively. On the external test set the DSC were 0.899 (±0.028) and 0.861 (±0.114), respectively. Mean Hausdorff distances were 0.67mm for both test sets. Bland-Altman plots showed a high agreement between 3D morphological measures from ground truth and model segmentations; however, a proportional bias was observed for voxel volume, surface area, sphericity and shape index. The qualitative evaluation showed no clear preference for either ground truth or model segmentation. The model achieved accurate and reliable segmentation of vessels and aneurysms internally and externally while also showing high agreement between 3D morphological measures from automatic and manual segmentations, indicating its potential clinical utility. Accurate intracranial aneurysm assessment is essential for treatment planning and risk stratification. Manual aneurysm segmentation is labor-intensive and subject to substantial inter- and intra-observer variability. Although automated segmentation approaches have been proposed, many suffer from limited accuracy, lack of robustness across datasets, or insufficient validation on heterogeneous, real-world data. As a result, reliable and generalizable tools for aneurysm segmentation and morphological analysis remain an unmet need. DIVA-seg, an nnU-Net-based model, achieved high aneurysm segmentation accuracy (DSC >0.86; HD <0.7mm) and close agreement with expert annotations in clinically relevant 3D morphological measures, demonstrating consistent performance across internal and external datasets. This work demonstrates a robust and generalizable approach for automated intracranial aneurysm segmentation, enabling reliable morphological analysis. The proposed method has the potential to streamline aneurysm monitoring, reduce observer variability, and support future automated tools for risk predictions and clinical decision making.
- 14 February 2026
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 47 (8) , ajnr.A9231-2138
Towards improved decision making of unruptured intracranial aneurysms using automated segmentation from MRA-TOF with iterative pseudo labeling
To enable accurate 3D morphological assessment and support clinical decision making, DIVA-seg: a Deep learning-based method for Intracranial Vessel and Aneurysm segmentation from MRA-TOF using a pseudo labeling approach was developed and validated. Three MRA-TOF datasets were used: 1) labeled data for training (n=57) and testing (n=14), 2) unlabeled data for pseudo labels (n=518), and 3) labeled data for external validation (n=82). An nnU-Net (Model 1) was iteratively trained for creating pseudo labels for Dataset 2. Cases with stable segmentation performance across iterations were selected for further training. Stable cases (n=484) were combined with Dataset 1 to train a second nnU-Net (Model 2). Performance testing on Dataset 1 and 3 comprised of Dice similarity coefficients (DSC), 95%-Hausdorff distances, 3D morphological measures, and a blinded qualitative evaluation. DIVA-seg achieved a mean (standard deviation) internal vessel and aneurysm DSC of 0.925 (±0.025) and 0.880 (±0.045), respectively. On the external test set the DSC were 0.899 (±0.028) and 0.861 (±0.114), respectively. Mean Hausdorff distances were 0.67mm for both test sets. Bland-Altman plots showed a high agreement between 3D morphological measures from ground truth and model segmentations; however, a proportional bias was observed for voxel volume, surface area, sphericity and shape index. The qualitative evaluation showed no clear preference for either ground truth or model segmentation. The model achieved accurate and reliable segmentation of vessels and aneurysms internally and externally while also showing high agreement between 3D morphological measures from automatic and manual segmentations, indicating its potential clinical utility. Accurate intracranial aneurysm assessment is essential for treatment planning and risk stratification. Manual aneurysm segmentation is labor-intensive and subject to substantial inter- and intra-observer variability. Although automated segmentation approaches have been proposed, many suffer from limited accuracy, lack of robustness across datasets, or insufficient validation on heterogeneous, real-world data. As a result, reliable and generalizable tools for aneurysm segmentation and morphological analysis remain an unmet need. DIVA-seg, an nnU-Net-based model, achieved high aneurysm segmentation accuracy (DSC >0.86; HD <0.7mm) and close agreement with expert annotations in clinically relevant 3D morphological measures, demonstrating consistent performance across internal and external datasets. This work demonstrates a robust and generalizable approach for automated intracranial aneurysm segmentation, enabling reliable morphological analysis. The proposed method has the potential to streamline aneurysm monitoring, reduce observer variability, and support future automated tools for risk predictions and clinical decision making.
- Open Access
Trends in Term-Equivalent Age Brain Volumes in Infants Born Across the Gestational Age Spectrum
Purpose: Our understanding of the influence of preterm birth and related perinatal exposures on early brain development is limited, hampering personalized optimization of neuroprotective strategies. This study assesses the effect of gestational age (GA) at birth on brain volumes at term-equivalent age (TEA) in infants without overt brain injury born across the GA spectrum. Methods: A cohort of infants born across the GA spectrum (25–40 weeks’ gestation) underwent 3T brain MRI around TEA (40–46 weeks postmenstrual age). Eight brain regions, intracranial and total tissue volumes were segmented using MANTiS (morphologically adaptive neonatal tissue segmentation toolbox). Segmentations were visually quality-checked and excluded if segmentation failed. Absolute TEA volume in relation to GA was assessed using univariate and multivariate (correction for postmenstrual age) linear regression analysis. Statistical significance was set at p < 0.05. Post hoc scatter plots of brain volumes relative to intracranial volumes were created. Results: Fifty infants were included (mean GA = 35.0 [SD = 3.3, range = 25.7–40.1] weeks). A higher GA at birth was significantly related to lower cerebrospinal fluid (p = 0.004) and amygdala (p = 0.02) volumes; no significant relation was found between GA and other volumes. Post hoc analyses showed positive trends between GA and several brain structures, including total brain tissue, cortical gray matter, deep gray matter, hippocampus, cerebellum and brainstem volumes. Conclusions: Our results suggest that GA has an effect on TEA brain volumes that is independent of brain lesions, with lower GA being associated with smaller brain tissue volumes and significantly larger cerebrospinal fluid volume. Preterm birth and related exposures may thus affect early brain growth and contribute to neurodevelopmental challenges encountered by preterm-born children.
Open AccessTrends in Term-Equivalent Age Brain Volumes in Infants Born Across the Gestational Age Spectrum
Purpose: Our understanding of the influence of preterm birth and related perinatal exposures on early brain development is limited, hampering personalized optimization of neuroprotective strategies. This study assesses the effect of gestational age (GA) at birth on brain volumes at term-equivalent age (TEA) in infants without overt brain injury born across the GA spectrum. Methods: A cohort of infants born across the GA spectrum (25–40 weeks’ gestation) underwent 3T brain MRI around TEA (40–46 weeks postmenstrual age). Eight brain regions, intracranial and total tissue volumes were segmented using MANTiS (morphologically adaptive neonatal tissue segmentation toolbox). Segmentations were visually quality-checked and excluded if segmentation failed. Absolute TEA volume in relation to GA was assessed using univariate and multivariate (correction for postmenstrual age) linear regression analysis. Statistical significance was set at p < 0.05. Post hoc scatter plots of brain volumes relative to intracranial volumes were created. Results: Fifty infants were included (mean GA = 35.0 [SD = 3.3, range = 25.7–40.1] weeks). A higher GA at birth was significantly related to lower cerebrospinal fluid (p = 0.004) and amygdala (p = 0.02) volumes; no significant relation was found between GA and other volumes. Post hoc analyses showed positive trends between GA and several brain structures, including total brain tissue, cortical gray matter, deep gray matter, hippocampus, cerebellum and brainstem volumes. Conclusions: Our results suggest that GA has an effect on TEA brain volumes that is independent of brain lesions, with lower GA being associated with smaller brain tissue volumes and significantly larger cerebrospinal fluid volume. Preterm birth and related exposures may thus affect early brain growth and contribute to neurodevelopmental challenges encountered by preterm-born children.
- Open Access
- 7 April 2025
- Published by Elsevier in European Journal of Radiology
- Vol. 187, 112098
Diffusion MRI tractography with along-tract profiling reveals subtle neurodevelopmental differences between moderate and late preterm infants
- 7 April 2025
- Published by Elsevier in European Journal of Radiology
- Vol. 187, 112098
Open AccessDiffusion MRI tractography with along-tract profiling reveals subtle neurodevelopmental differences between moderate and late preterm infants
- 14 August 2024
- Published by Springer Nature in Pediatric Research
- Vol. 97 (3) , 880-897
Methodological considerations on diffusion MRI tractography in infants aged 0–2 years: a scoping review
Diffusion MRI (dMRI) enables studying the complex architectural organization of the brain’s white matter (WM) through virtual reconstruction of WM fiber tracts (tractography). Despite the anticipated clinical importance of applying tractography to study structural connectivity and tract development during the critical period of rapid infant brain maturation, detailed descriptions on how to approach tractography in young infants are limited. Over the past two decades, tractography from infant dMRI has mainly been applied in research settings and focused on diffusion tensor imaging (DTI). Only few studies used techniques superior to DTI in terms of disentangling information on the brain’s organizational complexity, including crossing fibers. While more advanced techniques may enhance our understanding of the intricate processes of normal and abnormal brain development and extensive knowledge has been gained from application on adult scans, their applicability in infants has remained underexplored. This may partially be due to the higher technical requirements versus the need to limit scan time in young infants. We review various previously described methodological practices for tractography in the infant brain (0–2 years-of-age) and provide recommendations to optimize advanced tractography approaches to enable more accurate reconstructions of the brain WM’s complexity. Impact Diffusion tensor imaging is the technique most frequently used for fiber tracking in the developing infant brain but is limited in capability to disentangle the complex white matter organization. Advanced tractography techniques allow for reconstruction of crossing fiber bundles to better reflect the brain’s complex organization. Yet, they pose practical and technical challenges in the fast developing young infant’s brain. Methods on how to approach advanced tractography in the young infant’s brain have hardly been described. Based on a literature review, recommendations are provided to optimize tractography for the developing infant brain, aiming to advance early diagnosis and neuroprotective strategies.
- 14 August 2024
- Published by Springer Nature in Pediatric Research
- Vol. 97 (3) , 880-897
Methodological considerations on diffusion MRI tractography in infants aged 0–2 years: a scoping review
Diffusion MRI (dMRI) enables studying the complex architectural organization of the brain’s white matter (WM) through virtual reconstruction of WM fiber tracts (tractography). Despite the anticipated clinical importance of applying tractography to study structural connectivity and tract development during the critical period of rapid infant brain maturation, detailed descriptions on how to approach tractography in young infants are limited. Over the past two decades, tractography from infant dMRI has mainly been applied in research settings and focused on diffusion tensor imaging (DTI). Only few studies used techniques superior to DTI in terms of disentangling information on the brain’s organizational complexity, including crossing fibers. While more advanced techniques may enhance our understanding of the intricate processes of normal and abnormal brain development and extensive knowledge has been gained from application on adult scans, their applicability in infants has remained underexplored. This may partially be due to the higher technical requirements versus the need to limit scan time in young infants. We review various previously described methodological practices for tractography in the infant brain (0–2 years-of-age) and provide recommendations to optimize advanced tractography approaches to enable more accurate reconstructions of the brain WM’s complexity. Impact Diffusion tensor imaging is the technique most frequently used for fiber tracking in the developing infant brain but is limited in capability to disentangle the complex white matter organization. Advanced tractography techniques allow for reconstruction of crossing fiber bundles to better reflect the brain’s complex organization. Yet, they pose practical and technical challenges in the fast developing young infant’s brain. Methods on how to approach advanced tractography in the young infant’s brain have hardly been described. Based on a literature review, recommendations are provided to optimize tractography for the developing infant brain, aiming to advance early diagnosis and neuroprotective strategies.
- Open Access
- 28 June 2024
- Published by Frontiers Media SA in Frontiers in Radiology
- Vol. 4, 1416672
Feasibility study to unveil the potential: considerations of constrained spherical deconvolution tractography with unsedated neonatal diffusion brain MRI data
Purpose: The study aimed to (1) assess the feasibility constrained spherical deconvolution (CSD) tractography to reconstruct crossing fiber bundles with unsedated neonatal diffusion MRI (dMRI), and (2) demonstrate the impact of spatial and angular resolution and processing settings on tractography and derived quantitative measures.Methods: For the purpose of this study, the term-equivalent dMRIs (single-shell b800, and b2000, both 5 b0, and 45 gradient directions) of two moderate-late preterm infants (with and without motion artifacts) from a local cohort [Brain Imaging in Moderate-late Preterm infants (BIMP) study; Calgary, Canada] and one infant from the developing human connectome project with high-quality dMRI (using the b2600 shell, comprising 20 b0 and 128 gradient directions, from the multi-shell dataset) were selected. Diffusion tensor imaging (DTI) and CSD tractography were compared on b800 and b2000 dMRI. Varying image resolution modifications, (pre-)processing and tractography settings were tested to assess their impact on tractography. Each experiment involved visualizing local modeling and tractography for the corpus callosum and corticospinal tracts, and assessment of morphological and diffusion measures.Results: Contrary to DTI, CSD enabled reconstruction of crossing fibers. Tractography was susceptible to image resolution, (pre-) processing and tractography settings. In addition to visual variations, settings were found to affect streamline count, length, and diffusion measures (fractional anisotropy and mean diffusivity). Diffusion measures exhibited variations of up to 23%.Conclusion: Reconstruction of crossing fiber bundles using CSD tractography with unsedated neonatal dMRI data is feasible. Tractography settings affected streamline reconstruction, warranting careful documentation of methods for reproducibility and comparison of cohorts.
- 28 June 2024
- Published by Frontiers Media SA in Frontiers in Radiology
- Vol. 4, 1416672
Open AccessFeasibility study to unveil the potential: considerations of constrained spherical deconvolution tractography with unsedated neonatal diffusion brain MRI data
Purpose: The study aimed to (1) assess the feasibility constrained spherical deconvolution (CSD) tractography to reconstruct crossing fiber bundles with unsedated neonatal diffusion MRI (dMRI), and (2) demonstrate the impact of spatial and angular resolution and processing settings on tractography and derived quantitative measures.Methods: For the purpose of this study, the term-equivalent dMRIs (single-shell b800, and b2000, both 5 b0, and 45 gradient directions) of two moderate-late preterm infants (with and without motion artifacts) from a local cohort [Brain Imaging in Moderate-late Preterm infants (BIMP) study; Calgary, Canada] and one infant from the developing human connectome project with high-quality dMRI (using the b2600 shell, comprising 20 b0 and 128 gradient directions, from the multi-shell dataset) were selected. Diffusion tensor imaging (DTI) and CSD tractography were compared on b800 and b2000 dMRI. Varying image resolution modifications, (pre-)processing and tractography settings were tested to assess their impact on tractography. Each experiment involved visualizing local modeling and tractography for the corpus callosum and corticospinal tracts, and assessment of morphological and diffusion measures.Results: Contrary to DTI, CSD enabled reconstruction of crossing fibers. Tractography was susceptible to image resolution, (pre-) processing and tractography settings. In addition to visual variations, settings were found to affect streamline count, length, and diffusion measures (fractional anisotropy and mean diffusivity). Diffusion measures exhibited variations of up to 23%.Conclusion: Reconstruction of crossing fiber bundles using CSD tractography with unsedated neonatal dMRI data is feasible. Tractography settings affected streamline reconstruction, warranting careful documentation of methods for reproducibility and comparison of cohorts.
- Open Access
- 7 March 2022
- Published by Wiley in Journal of Neuroimaging
- Vol. 32 (3) , 480-492
Improved neonatal brain MRI segmentation by interpolation of motion corrupted slices
Background and Purpose: To apply and evaluate an intensity‐based interpolation technique, enabling segmentation of motion‐affected neonatal brain MRI. Methods: Moderate‐late preterm infants were enrolled in a prospective cohort study (Brain Imaging in Moderate‐late Preterm infants “BIMP‐study”) between August 2017 and November 2019. T2‐weighted MRI was performed around term equivalent age on a 3T MRI. Scans without motion ( n = 27 [24%], control group) and with moderate‐severe motion ( n = 33 [29%]) were included. Motion‐affected slices were re‐estimated using intensity‐based shape‐preserving cubic spline interpolation, and automatically segmented in eight structures. Quality of interpolation and segmentation was visually assessed for errors after interpolation. Reliability was tested using interpolated control group scans (18/54 axial slices). Structural similarity index (SSIM) was used to compare T2‐weighted scans, and Sørensen‐Dice was used to compare segmentation before and after interpolation. Finally, volumes of brain structures of the control group were used assessing sensitivity (absolute mean fraction difference) and bias (confidence interval of mean difference). Results: Visually, segmentation of 25 scans (22%) with motion artifacts improved with interpolation, while segmentation of eight scans (7%) with adjacent motion‐affected slices did not improve. Average SSIM was .895 and Sørensen‐Dice coefficients ranged between .87 and .97. Absolute mean fraction difference was ≤0.17 for less than or equal to five interpolated slices. Confidence intervals revealed a small bias for cortical gray matter (0.14‐3.07 cm 3 ), cerebrospinal fluid (0.39‐1.65 cm 3 ), deep gray matter (0.74‐1.01 cm 3 ), and brainstem volumes (0.07‐0.28 cm 3 ) and a negative bias in white matter volumes (–4.47 to –1.65 cm 3 ). Conclusion: According to qualitative and quantitative assessment, intensity‐based interpolation reduced the percentage of discarded scans from 29% to 7%.
- 7 March 2022
- Published by Wiley in Journal of Neuroimaging
- Vol. 32 (3) , 480-492
Open AccessImproved neonatal brain MRI segmentation by interpolation of motion corrupted slices
Background and Purpose: To apply and evaluate an intensity‐based interpolation technique, enabling segmentation of motion‐affected neonatal brain MRI. Methods: Moderate‐late preterm infants were enrolled in a prospective cohort study (Brain Imaging in Moderate‐late Preterm infants “BIMP‐study”) between August 2017 and November 2019. T2‐weighted MRI was performed around term equivalent age on a 3T MRI. Scans without motion ( n = 27 [24%], control group) and with moderate‐severe motion ( n = 33 [29%]) were included. Motion‐affected slices were re‐estimated using intensity‐based shape‐preserving cubic spline interpolation, and automatically segmented in eight structures. Quality of interpolation and segmentation was visually assessed for errors after interpolation. Reliability was tested using interpolated control group scans (18/54 axial slices). Structural similarity index (SSIM) was used to compare T2‐weighted scans, and Sørensen‐Dice was used to compare segmentation before and after interpolation. Finally, volumes of brain structures of the control group were used assessing sensitivity (absolute mean fraction difference) and bias (confidence interval of mean difference). Results: Visually, segmentation of 25 scans (22%) with motion artifacts improved with interpolation, while segmentation of eight scans (7%) with adjacent motion‐affected slices did not improve. Average SSIM was .895 and Sørensen‐Dice coefficients ranged between .87 and .97. Absolute mean fraction difference was ≤0.17 for less than or equal to five interpolated slices. Confidence intervals revealed a small bias for cortical gray matter (0.14‐3.07 cm 3 ), cerebrospinal fluid (0.39‐1.65 cm 3 ), deep gray matter (0.74‐1.01 cm 3 ), and brainstem volumes (0.07‐0.28 cm 3 ) and a negative bias in white matter volumes (–4.47 to –1.65 cm 3 ). Conclusion: According to qualitative and quantitative assessment, intensity‐based interpolation reduced the percentage of discarded scans from 29% to 7%.
- Open Access
- 1 September 2021
- Published by Elsevier in European Journal of Paediatric Neurology
- Vol. 34, 91-98
Mild brain lesions do not affect brain volumes in moderate-late preterm infants
- 1 September 2021
- Published by Elsevier in European Journal of Paediatric Neurology
- Vol. 34, 91-98
Open AccessMild brain lesions do not affect brain volumes in moderate-late preterm infants