Automated Segmentation of Intracranial Arteries on 4D Flow MRI for Hemodynamic Quantification
Preprint
Abstract
Accurate vessel segmentation is essential for reliable hemodynamic quantification in 4D Flow MRI. Automated segmentation with deep learning offers a promising alternative to the time-consuming, operator-dependent manual segmentation, but its application is often hindered by the scarcity of labeled datasets. Moreover, while a previous study has evaluated the impact of automated vs manual segmentation on downstream intracranial hemodynamic quantification, it remains to be explored whether variability between different automated segmentation methods affects hemodynamic quantification significantly, particularly in the context of intracranial 7T 4D Flow MRI. We investigated a transfer learning–based intracranial artery segmentation model using a 3D full-resolution nnU-Net, pretrained on 355 TOF-MRA scans and fine-tuned on 11 7T 4D Flow MRI scans. The model was compared with two published models: a direct-transfer U-Net pretrained only on TOF-MRA without 4D Flow MRI fine-tuning, and a DenseNet U-Net trained from scratch on the same 11 7T 4D Flow MRI scans. Segmentation performance was evaluated against the manual reference on test sets with different resolutions and the impact on downstream hemodynamic quantification was assessed. The transfer learning–based nnU-Net achieved the highest Dice score (>0.85), the lowest HD95 (∼3 mm), and the highest ICCs in cross-sectional area (0.62–0.87, except PCAs) and mean blood flow (0.78– 0.98). For wall shear stress (WSS) quantification, the transfer learning–based nnU-Net segmentations achieved the closest agreement with the manual reference (mean = 1.57 ± 0.63 Pa, ICC = 0.96; max = 2.16 ± 1.05 Pa, ICC = 0.97) and minimal bias (≤ 1.7%), whereas U-Net and DenseNet U-Net showed systematic under-(−5%) and overestimation (+7%), respectively. However, several vessel segments, including the ACA for DenseNet U-Net and the BA for U-Net, showed statistically significant differences (ANOVA post-hoc correction P < 0.05) in the flow-related metrics when compared with the manual reference. These results suggest that a transfer learning–based nnU-Net can provide accurate automated intracranial artery segmentation for 7T 4D Flow MRI. Differences among automated segmentation pipelines and associated analysis regions were linked to differences in downstream hemodynamic estimates.Keywords
Funding Information
- Wellcome Trust (215944/Z/19/Z)
This publication has 29 references indexed in Scilit:
- Automated Cerebrovascular Segmentation and Visualization of Intracranial Time-of-Flight Magnetic Resonance Angiography Based on Deep LearningJournal of Imaging Informatics in Medicine, 2024
- CAVE: Cerebral artery–vein segmentation in digital subtraction angiographyComputerized Medical Imaging and Graphics, 2024
- Hemodynamic Parameters in the Parent Arteries of Unruptured Intracranial Aneurysms Depend on Aneurysm Size and Are Different Compared to Contralateral Arteries: A 7 Tesla 4D Flow MRI StudyJournal of Magnetic Resonance Imaging, 2023
- Domain Adaptation for Automatic Aorta Segmentation of 4D Flow Magnetic Resonance Imaging Data from Multiple Vendor Scanners2021
- Fully automated 3D aortic segmentation of 4D flow MRI for hemodynamic analysis using deep learningMagnetic Resonance in Medicine, 2020
- Pseudo‐spiral sampling and compressed sensing reconstruction provides flexibility of temporal resolution in accelerated aortic 4D flow MRI: A comparison with k‐t principal component analysisNMR in Biomedicine, 2020
- Accuracy of blood flow assessment in cerebral arteries with 4D flow MRI: Evaluation with three segmentation methodsJournal of Magnetic Resonance Imaging, 2019
- Fast 4D flow MRI intracranial segmentation and quantification in tortuous arteriesJournal of Magnetic Resonance Imaging, 2015
- Wall shear stress estimated with phase contrast MRI in an in vitro and in vivo intracranial aneurysmJournal of Magnetic Resonance Imaging, 2013
- 4D flow MRIJournal of Magnetic Resonance Imaging, 2012