MGMagammed A. Gadzhiev

Magammed A. Gadzhiev

*This is an algorithmically generated author record based on publicly available information.

Magammed A. Gadzhiev has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative evaluation of the accuracy of the dental arch display using modern intraoral three-dimensional scanners

    by Irina D. Borodina, Leon S. Grigoryants, Magammed A. Gadzhiev, Svetlana S. Apresyan, Roman V. Batov, Alexander G. Stepanov

    BACKGROUND: At present, modern dentists used dental intraoral three-dimensional (3D) scanners routinely in their daily work. Obtaining an optical 3D image of the teeth and dentition helps avoid errors at the stage of obtaining traditional silicone impressions and significantly reduces the level of discomfort during dental procedures. Intraoral scanner systems are commercially available today. Despite their advantages over traditional silicone impressions, the accuracy of the optical impressions obtained during total and subtotal prosthetics on the upper and lower jaw are still questionable. AIM: This study aimed to evaluate the accuracy of scanning models of the patients dentition obtained using intraoral scanners and to determine the currently available models of digital devices that are optimal in terms of price and quality. MATERIAL AND METHODS: The reference scan (master model) was an optical image of the reference model of the upper jaw of a patient with a full dentition made by additive 3D-printing technology obtained using a laboratory scanner. To level out the shrinkage errors of photopolymerization materials, the resulting model was scanned on the same day using intraoral scanners selected for the study. The obtained scan results were compared with the reference scan of the control group. Based on the measurements made at reference points, the average error value relative to the master model and its precision were calculated for each scanner. In addition to the average values, the error parameters of the scanners in the frontal and chewing sections were calculated, as well as the arc error, which was equal to the difference in the values of the discrepancy at the reference points at which the maximum and minimum values were obtained. The cost and availability of scanners on the domestic market, under the sanctions policy of foreign countries, were also considered. RESULTS: The CEREC Primescan AC scanner showed the best accuracy according to the results of model discrepancies. It has an average error of 13.727.34. The arc error was 18.8 microns, and the discrepancies in the frontal area and chewing area were 18 and 6.8 microns, respectively. 3Shape Trios 3 scanner has the closest accuracy, with an average error of 16.285.94 microns. The error value of Aoralscan 3 was 42.0818.34 microns, its arc accuracy was 65 microns, and the discrepancies in the frontal and chewing areas were 33 and 55.1 microns, respectively. Emerald S Mode C had an average error of 35.8422.29 microns, which was higher than that of Medit i500 and Aoralscan 3; however, Aoralscan 3 showed better precision (18.34 microns versus 22.29 microns). According to the comparison results of the models in the MeshLab program, CEREC Primescan AC showed the smallest median of distances (18 microns). The TRIOS 3 and Emerald S Mode C differed from the standard by an average of 29 microns, and Aoralscan 3 scanners had of 33 microns and Medit i500 had 41 microns. CONCLUSION: The precision of Aoralscan 3 scanner, which is the best among its analogs in the price category, makes it the most affordable scanner for dental surgical, orthodontic, and orthopedic fields. CEREC Primescan AC is the leader of the premium scanners involved in the study and available in the dental market.


  • Clinical efficacy of occlusive splints manufactured by computer modeling and volumetric printing in patients with bruxism: research results and a clinical case

    by Samvel V. Apresyan, Alexander G. Stepanov, Magammed A. Gadzhiev, Irina D. Borodina, Artur V. Heigetyan

    BACKGROUND: Among dental diseases, various types of musculoskeletal dysfunctions occupy a special place. The myogenic theory of temporomandibular joint dysfunction is interesting, where the fundamental role is assigned to the parafunctional state of the masticatory muscles. Analysis of the results of electromyographic studies has shown that patients with TMJ disorders complicated by muscle hypertension have significant functional disorders of the masticatory muscles. Also, the causes of TMJ dysfunction include bruxism, which can occur against the background of parafunctions of the masticatory muscles. To date, there are a large number of methods for the treatment of TMJ dysfunction: splint therapy, occlusive and immobilizing splints. CAD/CAM computer technologies have also become widespread, which are used for the manufacture of these structures. But there are no uniform treatment standards, therefore, studies and comparisons of different techniques are relevant. AIM: the effectiveness of treatment of patients with bruxism by developing a clinical protocol for the use of an occlusive splint made by volumetric printing. MATERIAL AND METHODS: To evaluate the effectiveness of occlusive splints manufactured by computer milling and 3D printing in patients with bruxism. All study participants at the stage of formation of clinical groups underwent a comprehensive dental examination, which included a clinical and instrumental examination, surface electromyography of the masticatory muscles, computer monitoring of occlusion, cone-beam computed tomography of the TMJ. To exclude the somatoform component from the pathogenesis of bruxism, an electroencephalogram (EEG) was performed in all patients at the stage of formation of clinical groups. At the first stage of treatment, all patients underwent selective grinding of centric and eccentric interferences under the control of a T-scan computer occlusion monitoring device, after which the therapeutic position of the mandible was determined, stabilizing nocturnal occlusal splints made by volumetric printing were manufactured and fixed. Monitoring of treatment results included clinical and instrumental examination and surface electromyography of the masticatory muscles, carried out 3.6 and 12 months after the start of treatment. Upon completion of treatment, an assessment of the integrity of occlusal splints was carried out. RESULTS: According to the results of the performed myography, at the time of the start of treatment, the PU coefficient was 74%, after 3 months, it significantly decreased by 6%, after 6 months, its decrease was recorded by 11%, and after 12 months by 16%. The assessment of the integrity of the occlusal splint was carried out at the end of treatment after 12 months, by combining virtual tire models in a computer program before and after the start of treatment obtained by laboratory scanning. When analyzing the comparison of virtual tire models, their almost complete identity was revealed, with the exception of one area on the occlusal surface, which is 0.044 mm, which is not critical in the general treatment concept. CONCLUSION: Taking into account the positive result of clinical testing of the proposed technology, it is advisable to conduct a randomized study to evaluate the effectiveness of the use of occlusive splints made by computer modeling and volumetric printing from domestic material in the treatment of patients with musculoskeletal dysfunction complicated by bruxism.


  • Анализ механических свойств материалов для стоматологических конструкций после проведения искусственного старения

    by С.в. Апресян, М.а. Гаджиев, К.с. Кравчук, Е.в. Гладких, Г.х. Султанова, А.а. Русаков, А.с. Усейнов

    Ключевой особенностью данной работы является исследование поведения механических свойств материалов для стоматологических конструкций в результате воздействия процесса, имитирующего старение, происходящее с материалами в ходе длительной эксплуатации. В статье приводятся результаты для материалов, напечатанных на 3D-принтере, а также полученных фрезерованием из заготовок. Измерения твердости и модуля упругости проводились методом наноиндентирования, коэффициентов линейного износа и трения – методом истирания, а модуля упругости, прочности и деформации – методом трехточечного изгиба.


  • Сравнительные испытания объемных и поверх­ностных механических свойств материалов для стоматологических конструкций, полученных с помощью аддитивных технологий

    by М.а. Гаджиев, К.с. Кравчук, Е.в. Гладких, Г.х. Султанова, А.а. Русаков, А.с. Усейнов, С.в. Апресян

    В работе приведены результаты испытания инструментальных твердости и модуля упругости, коэффициентов линейного износа и трения исходных и полированных образцов для стоматологических конструкций, полученных с помощью аддитивных технологий. Помимо исследования локальных механических свойств, проводилось измерение объемных характеристик – модуля упругости, прочности и деформации – с помощью метода трехточечного изгиба. Поверхность образцов, подвергнутых испытанию на изгиб, не проходила пробоподготовку.