IBIrina D. Borodina

Irina D. Borodina

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Irina D. Borodina has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Clinical efficiency of occlusive splints in the treatment of patients with temporomandibular joint dysfunction complicated by bruxism

    by I.D. Borodina, S.V. Apresyan, A.G. Stepanov, D.S. Butkov, G.V. Sanosyan

    Objective. Improving the effectiveness of treatment of patients with temporomandibular joint (TMJ) dysfunction complicated by bruxism. Material and methods. 70 patients with signs of parafunction of the masticatory muscles were selected for the clinical study. The patients were divided into 2 groups of 35 people. Splints were made for patients from the groups using 2 different 3D printing methods. The treatment was monitored using clinical and instrumental studies, electromyography of the muscles themselves and computed tomography of the TMJ after 3, 6 and 12 months. Results. The severity of hypertonicity of the masticatory muscles decreased by the end of 3 months of treatment with the help of repositioning occlusal splints. After 6 months of treatment, the mean BEA decreased in both study groups, but to a lesser extent than in the first 3 months. After wearing a splint after 12 months, the decrease in muscle tone was insignificant. Conclusion. The clinical use of positioning splints plays a crucial role in the stabilization of occlusion and is a mandatory stage of complex treatment of patients with pathology of the occlusal-musculoskeletal complex.


  • Development of a personalized device for the study of masticatory and temporal muscles in patients with TMJ dysfunction

    by Samvel V. Apresyan, Alexandr G. Stepanov, Irina D. Borodina, Maksim A. Kiryushin

    BACKGROUND: The current gold standard for diagnosing a masticatory muscle condition is electromyography (EMG). This method allows us to evaluate the bioelectric potential of the muscle selected for diagnosis, bioelectric rest, the average amplitude of the biopotentials, the time of one chewing cycle, and the number of chewing movements performed. EMG is used in dental practice, and the electrodes are attached to the skin with glue or an electrically conductive gel. Installation often takes a long time and the reliability of the results decreases due to the movement of the sensors. Furthermore, when conducting several EMG studies on a patient at various stages of treatment, the motor point may not be in the same place, suggesting that the data obtained and any comparisons are inaccurate. AIM: To design and develop a personalized device for performing masticatory muscle EMG with accurate repetition. MATERIALS AND METHODS: Analysis of information in the literature made it possible to develop and produce a device for conducting EMG. RESULTS: The technical result was a simplification of the methodology, including improved fixation of the sensors, which reduced the EMG time, and the ability to repeat the study at various stages of a patients treatment. CONCLUSION: This device and EMG method provide a simplified way to obtain an accurate result in a shorter time. Thus, the data obtained would be representative if the study was repeated.

  • Open Access

    Comparative evaluation of the accuracy of the dental arch display using modern intraoral three-dimensional scanners

    by Irina D. Borodina, Leon S. Grigoryants, Magammed A. Gadzhiev, Svetlana S. Apresyan, Roman V. Batov, Alexander G. Stepanov

    BACKGROUND: At present, modern dentists used dental intraoral three-dimensional (3D) scanners routinely in their daily work. Obtaining an optical 3D image of the teeth and dentition helps avoid errors at the stage of obtaining traditional silicone impressions and significantly reduces the level of discomfort during dental procedures. Intraoral scanner systems are commercially available today. Despite their advantages over traditional silicone impressions, the accuracy of the optical impressions obtained during total and subtotal prosthetics on the upper and lower jaw are still questionable. AIM: This study aimed to evaluate the accuracy of scanning models of the patients dentition obtained using intraoral scanners and to determine the currently available models of digital devices that are optimal in terms of price and quality. MATERIAL AND METHODS: The reference scan (master model) was an optical image of the reference model of the upper jaw of a patient with a full dentition made by additive 3D-printing technology obtained using a laboratory scanner. To level out the shrinkage errors of photopolymerization materials, the resulting model was scanned on the same day using intraoral scanners selected for the study. The obtained scan results were compared with the reference scan of the control group. Based on the measurements made at reference points, the average error value relative to the master model and its precision were calculated for each scanner. In addition to the average values, the error parameters of the scanners in the frontal and chewing sections were calculated, as well as the arc error, which was equal to the difference in the values of the discrepancy at the reference points at which the maximum and minimum values were obtained. The cost and availability of scanners on the domestic market, under the sanctions policy of foreign countries, were also considered. RESULTS: The CEREC Primescan AC scanner showed the best accuracy according to the results of model discrepancies. It has an average error of 13.727.34. The arc error was 18.8 microns, and the discrepancies in the frontal area and chewing area were 18 and 6.8 microns, respectively. 3Shape Trios 3 scanner has the closest accuracy, with an average error of 16.285.94 microns. The error value of Aoralscan 3 was 42.0818.34 microns, its arc accuracy was 65 microns, and the discrepancies in the frontal and chewing areas were 33 and 55.1 microns, respectively. Emerald S Mode C had an average error of 35.8422.29 microns, which was higher than that of Medit i500 and Aoralscan 3; however, Aoralscan 3 showed better precision (18.34 microns versus 22.29 microns). According to the comparison results of the models in the MeshLab program, CEREC Primescan AC showed the smallest median of distances (18 microns). The TRIOS 3 and Emerald S Mode C differed from the standard by an average of 29 microns, and Aoralscan 3 scanners had of 33 microns and Medit i500 had 41 microns. CONCLUSION: The precision of Aoralscan 3 scanner, which is the best among its analogs in the price category, makes it the most affordable scanner for dental surgical, orthodontic, and orthopedic fields. CEREC Primescan AC is the leader of the premium scanners involved in the study and available in the dental market.


  • Clinical efficacy of occlusive splints manufactured by computer modeling and volumetric printing in patients with bruxism: research results and a clinical case

    by Samvel V. Apresyan, Alexander G. Stepanov, Magammed A. Gadzhiev, Irina D. Borodina, Artur V. Heigetyan

    BACKGROUND: Among dental diseases, various types of musculoskeletal dysfunctions occupy a special place. The myogenic theory of temporomandibular joint dysfunction is interesting, where the fundamental role is assigned to the parafunctional state of the masticatory muscles. Analysis of the results of electromyographic studies has shown that patients with TMJ disorders complicated by muscle hypertension have significant functional disorders of the masticatory muscles. Also, the causes of TMJ dysfunction include bruxism, which can occur against the background of parafunctions of the masticatory muscles. To date, there are a large number of methods for the treatment of TMJ dysfunction: splint therapy, occlusive and immobilizing splints. CAD/CAM computer technologies have also become widespread, which are used for the manufacture of these structures. But there are no uniform treatment standards, therefore, studies and comparisons of different techniques are relevant. AIM: the effectiveness of treatment of patients with bruxism by developing a clinical protocol for the use of an occlusive splint made by volumetric printing. MATERIAL AND METHODS: To evaluate the effectiveness of occlusive splints manufactured by computer milling and 3D printing in patients with bruxism. All study participants at the stage of formation of clinical groups underwent a comprehensive dental examination, which included a clinical and instrumental examination, surface electromyography of the masticatory muscles, computer monitoring of occlusion, cone-beam computed tomography of the TMJ. To exclude the somatoform component from the pathogenesis of bruxism, an electroencephalogram (EEG) was performed in all patients at the stage of formation of clinical groups. At the first stage of treatment, all patients underwent selective grinding of centric and eccentric interferences under the control of a T-scan computer occlusion monitoring device, after which the therapeutic position of the mandible was determined, stabilizing nocturnal occlusal splints made by volumetric printing were manufactured and fixed. Monitoring of treatment results included clinical and instrumental examination and surface electromyography of the masticatory muscles, carried out 3.6 and 12 months after the start of treatment. Upon completion of treatment, an assessment of the integrity of occlusal splints was carried out. RESULTS: According to the results of the performed myography, at the time of the start of treatment, the PU coefficient was 74%, after 3 months, it significantly decreased by 6%, after 6 months, its decrease was recorded by 11%, and after 12 months by 16%. The assessment of the integrity of the occlusal splint was carried out at the end of treatment after 12 months, by combining virtual tire models in a computer program before and after the start of treatment obtained by laboratory scanning. When analyzing the comparison of virtual tire models, their almost complete identity was revealed, with the exception of one area on the occlusal surface, which is 0.044 mm, which is not critical in the general treatment concept. CONCLUSION: Taking into account the positive result of clinical testing of the proposed technology, it is advisable to conduct a randomized study to evaluate the effectiveness of the use of occlusive splints made by computer modeling and volumetric printing from domestic material in the treatment of patients with musculoskeletal dysfunction complicated by bruxism.