Julia Vogler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Julia Vogler has a total of 375 co-authors. Here are the top co-authors by number of shared publications:
- Roland Richard Tilz
Department of Rhythmology, University Heart Center, University Hospital Schleswig-Holstein , Lübeck
21 shared publications - Christian-Hendrik Heeger
Department of Rhythmology, Cardiology and Internal Medicine, Asklepios Klinik Hamburg Altona , Hamburg
14 shared publications - Karl-Heinz Kuck
University Heart Centre Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, Campus Lübeck 23538, Germany
11 shared publications - Charlotte Eitel
University Heart Centre Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, Campus Lübeck 23538, Germany
8 shared publications - Sorin Stefan Popescu
Department of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Lübeck, Germany
8 shared publications - Daniel Steven
Department of Electrophysiology, University of Cologne, Heart Center , Cologne
7 shared publications
Latest Publications
- Open Access
- 18 November 2026
- Published by Oxford University Press (OUP) in EP Europace
Venous Vascular Closure System Versus Conventional Figure of Eight Suture Following Single Shot Device Pulmonary Vein Isolation: The VASC-AF Study
Aims: Optimization of femoral venous access management has become increasingly important as catheter ablation of atrial fibrillation (AF) continues to evolve towards greater safety with accelerated recovery pathways. We evaluated the efficacy and safety of a bioabsorbable venous vascular closure system (VCS) compared with a conventional figure-of-eight (F8) suture and manual compression following contemporary single-shot pulmonary vein isolation (PVI). Methods and Results: VASC-AF was a prospective, multicentre, randomized controlled trial performed at three German electrophysiology centres. One hundred consecutive patients undergoing single-shot PVI were randomized in a 1:1 ratio to femoral venous closure using the VASCADE MVP VCS; (n=50) or conventional F8 suture (n=50). The primary efficacy endpoint was time to ambulation. The primary safety endpoint comprised major periprocedural adverse events requiring medical intervention before hospital discharge. Baseline characteristics and procedural variables were comparable between study groups. Median time to ambulation was significantly shorter following vascular closure with VCS compared with F8 sutures (120 [120–150] vs. 180 [180–240] min; P=0.015). Likewise, time to haemostasis (0.5 [0.5–2] vs. 1 [1–2] min; P=0.021) and time to discharge eligibility (2.5 [2.1–3.0] vs. 4.0 [3.0–5.0] h; P=0.019) were significantly reduced. Major adverse events occurred infrequently and did not differ significantly between groups. In contrast, vascular closure using VCS significantly reduced minor vascular access complications (6% vs. 26%; P=0.006), groin pain, and patient discomfort while improving overall post-procedural satisfaction. Conclusion: Among patients undergoing contemporary single-shot AF ablation, use of a bioabsorbable VCS significantly accelerated post-procedural recovery while maintaining a comparable major safety profile. Reduced access-site complications and improved patient-reported outcomes support VCS as an important component of enhanced recovery pathways following AF ablation especially in an ambulatory or Same-Day Discharge setting.
- 18 November 2026
- Published by Oxford University Press (OUP) in EP Europace
Open AccessVenous Vascular Closure System Versus Conventional Figure of Eight Suture Following Single Shot Device Pulmonary Vein Isolation: The VASC-AF Study
Aims: Optimization of femoral venous access management has become increasingly important as catheter ablation of atrial fibrillation (AF) continues to evolve towards greater safety with accelerated recovery pathways. We evaluated the efficacy and safety of a bioabsorbable venous vascular closure system (VCS) compared with a conventional figure-of-eight (F8) suture and manual compression following contemporary single-shot pulmonary vein isolation (PVI). Methods and Results: VASC-AF was a prospective, multicentre, randomized controlled trial performed at three German electrophysiology centres. One hundred consecutive patients undergoing single-shot PVI were randomized in a 1:1 ratio to femoral venous closure using the VASCADE MVP VCS; (n=50) or conventional F8 suture (n=50). The primary efficacy endpoint was time to ambulation. The primary safety endpoint comprised major periprocedural adverse events requiring medical intervention before hospital discharge. Baseline characteristics and procedural variables were comparable between study groups. Median time to ambulation was significantly shorter following vascular closure with VCS compared with F8 sutures (120 [120–150] vs. 180 [180–240] min; P=0.015). Likewise, time to haemostasis (0.5 [0.5–2] vs. 1 [1–2] min; P=0.021) and time to discharge eligibility (2.5 [2.1–3.0] vs. 4.0 [3.0–5.0] h; P=0.019) were significantly reduced. Major adverse events occurred infrequently and did not differ significantly between groups. In contrast, vascular closure using VCS significantly reduced minor vascular access complications (6% vs. 26%; P=0.006), groin pain, and patient discomfort while improving overall post-procedural satisfaction. Conclusion: Among patients undergoing contemporary single-shot AF ablation, use of a bioabsorbable VCS significantly accelerated post-procedural recovery while maintaining a comparable major safety profile. Reduced access-site complications and improved patient-reported outcomes support VCS as an important component of enhanced recovery pathways following AF ablation especially in an ambulatory or Same-Day Discharge setting.
- Open Access
- 17 November 2026
- Published by Oxford University Press (OUP) in European Heart Journal Open
Real-World Comparison of Cryoballoon and Pulsed Field Ablation for First-Time Pulmonary Vein Isolation
Background: Cryoballoon (CB) ablation has been an established single-shot technique for first-time pulmonary vein isolation (PVI), whereas pulsed field ablation (PFA) is being increasingly adopted in clinical practice. Although both technologies are designed to facilitate efficient PVI, comparative real-world evidence from large cohorts remains limited. Methods: We conducted a retrospective analysis of consecutive patients undergoing index pulmonary vein isolation (PVI) at a high-volume German tertiary referral center between 2021 and 2025. Clinical baseline characteristics, procedural metrics, and acute safety outcomes were collected using a standardized approach and subsequently analyzed. The primary efficacy endpoint was the recurrence of atrial tachyarrhythmia, documented by ECG or Holter monitoring after completion of a prespecified 90-day blanking period. Secondary endpoints included acute procedural efficacy and safety, early atrial tachyarrhythmia recurrence during the blanking period, and the durability of pulmonary vein isolation (PVI), determined by high-density electroanatomical remapping at the time of repeat ablation. Results: A total of 1,961 patients were included in the analysis, of whom 1,369 underwent cryoballoon (CB) ablation and 592 underwent pulsed field ablation (PFA) using a pentaspline catheter. Baseline characteristics were comparable between groups with respect to sex, age, atrial fibrillation (AF) type, left ventricular ejection fraction, history of stroke/transient ischemic attack (TIA), antiarrhythmic drug therapy, and anticoagulation status. Median procedure duration was shorter in the PFA group compared with the CB group (46 [Q1–Q3: 40–55] vs. 75 [60–85] minutes; p<0.001). Acute safety outcomes were similar between groups. Major complications occurred in 0.8% of CB procedures and 0.5% of PFA procedures (p=0.77), while minor complications were observed in 1.2% and 0.4% of procedures, respectively (p=0.091). During a median follow-up of 1,076 days (95% confidence interval [CI] 972–1,243), the incidence of atrial tachyarrhythmia recurrence beyond the 90-day blanking period did not differ significantly between groups (hazard ratio [HR] 1.02, 95% CI 0.804–1.294; p=0.827). Repeat ablation was performed in 204 patients (10.4%), including 169 of 1,369 patients (12.3%) in the CB group and 35 of 592 patients (5.9%) in the PFA group. Among patients undergoing repeat procedures, complete pulmonary vein (PV) isolation at high-density remapping was observed more frequently following PFA than following CB ablation (45.7% vs. 22.5%; p=0.01). Reconnection rates in the right superior and right inferior PVs were lower after PFA compared with CB ablation (14.3% vs. 50.3% and 14.3% vs. 48.5%, respectively; both p<0.001). Conclusion: In this large real-world cohort, both CB and PFA were associated with favorable acute safety profiles and comparable long-term freedom from atrial tachyarrhythmia recurrence. PVI durability differed between treatment modalities, with PFA demonstrating a higher proportion of complete pulmonary vein isolation using high-density remapping compared with CB ablation.
- 17 November 2026
- Published by Oxford University Press (OUP) in European Heart Journal Open
Open AccessReal-World Comparison of Cryoballoon and Pulsed Field Ablation for First-Time Pulmonary Vein Isolation
Background: Cryoballoon (CB) ablation has been an established single-shot technique for first-time pulmonary vein isolation (PVI), whereas pulsed field ablation (PFA) is being increasingly adopted in clinical practice. Although both technologies are designed to facilitate efficient PVI, comparative real-world evidence from large cohorts remains limited. Methods: We conducted a retrospective analysis of consecutive patients undergoing index pulmonary vein isolation (PVI) at a high-volume German tertiary referral center between 2021 and 2025. Clinical baseline characteristics, procedural metrics, and acute safety outcomes were collected using a standardized approach and subsequently analyzed. The primary efficacy endpoint was the recurrence of atrial tachyarrhythmia, documented by ECG or Holter monitoring after completion of a prespecified 90-day blanking period. Secondary endpoints included acute procedural efficacy and safety, early atrial tachyarrhythmia recurrence during the blanking period, and the durability of pulmonary vein isolation (PVI), determined by high-density electroanatomical remapping at the time of repeat ablation. Results: A total of 1,961 patients were included in the analysis, of whom 1,369 underwent cryoballoon (CB) ablation and 592 underwent pulsed field ablation (PFA) using a pentaspline catheter. Baseline characteristics were comparable between groups with respect to sex, age, atrial fibrillation (AF) type, left ventricular ejection fraction, history of stroke/transient ischemic attack (TIA), antiarrhythmic drug therapy, and anticoagulation status. Median procedure duration was shorter in the PFA group compared with the CB group (46 [Q1–Q3: 40–55] vs. 75 [60–85] minutes; p<0.001). Acute safety outcomes were similar between groups. Major complications occurred in 0.8% of CB procedures and 0.5% of PFA procedures (p=0.77), while minor complications were observed in 1.2% and 0.4% of procedures, respectively (p=0.091). During a median follow-up of 1,076 days (95% confidence interval [CI] 972–1,243), the incidence of atrial tachyarrhythmia recurrence beyond the 90-day blanking period did not differ significantly between groups (hazard ratio [HR] 1.02, 95% CI 0.804–1.294; p=0.827). Repeat ablation was performed in 204 patients (10.4%), including 169 of 1,369 patients (12.3%) in the CB group and 35 of 592 patients (5.9%) in the PFA group. Among patients undergoing repeat procedures, complete pulmonary vein (PV) isolation at high-density remapping was observed more frequently following PFA than following CB ablation (45.7% vs. 22.5%; p=0.01). Reconnection rates in the right superior and right inferior PVs were lower after PFA compared with CB ablation (14.3% vs. 50.3% and 14.3% vs. 48.5%, respectively; both p<0.001). Conclusion: In this large real-world cohort, both CB and PFA were associated with favorable acute safety profiles and comparable long-term freedom from atrial tachyarrhythmia recurrence. PVI durability differed between treatment modalities, with PFA demonstrating a higher proportion of complete pulmonary vein isolation using high-density remapping compared with CB ablation.
- Open Access
- 2 June 2026
- Vol. 28 (6)
Impact of a balloon-in-basket pulsed field ablation catheter on oesophageal temperature changes during pulmonary vein isolation.
- 2 June 2026
- Vol. 28 (6)
Open AccessImpact of a balloon-in-basket pulsed field ablation catheter on oesophageal temperature changes during pulmonary vein isolation.
- Top Cited Papers
- 14 April 2026
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 47 (36) , 5142-5151
Ultrasound-guided vs conventional venous puncture for atrial fibrillation ablation: the ULYSSES trial
Background and Aims: Vascular access site complications are the most common procedure-related adverse event of atrial fibrillation catheter ablation. Whether ultrasound-guided femoral venous puncture reduces these vascular access complications remains uncertain. Methods: In this investigator-initiated, multicentre, open-label, superiority trial, patients undergoing atrial fibrillation or left atrial tachycardia catheter ablation were randomized to an ultrasound-guided venous puncture strategy (intervention group) or to a conventional venous puncture group guided by palpation (control group). The composite primary outcome was the occurrence of venous access site complications until 30 days after the procedure, defined as arteriovenous fistula, false aneurysm, or access site bleeding requiring intervention or leading to prolonged hospitalization. Secondary endpoints included procedure duration, puncture duration, procedure-related stroke/transient ischaemic attack within 30 days, number of unintended arterial punctures, and number of failed venous access attempts, as well as hospital stay duration. Results: In six centres, 986 patients were randomized. A total of 496 patients were assigned to the ultrasound-guided puncture group, and 490 patients to the conventional puncture group. The trial was stopped for efficacy, following the first interim analysis after enrolment of half of the planned patients. The composite primary outcome occurred in 3 patients (0.6%) in the intervention group and 16 patients (3.3%) in the control group (risk ratio 0.19; 95% confidence interval 0.05–0.63; P = .002). Additionally, ultrasound-guided venous puncture significantly reduced the rate of an unintended arterial puncture (2% vs 16%, P < .0001) and the rate of unsuccessful venous access attempts requiring crossover to the other group (0.2% vs 8.2%, P < .0001). Conclusions: Ultrasound-guided venous access for atrial fibrillation ablation procedures significantly reduced vascular access site complications. ULYSSES ClinicalTrials.gov number: NCT06403527.
- 14 April 2026
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 47 (36) , 5142-5151
Top Cited PapersUltrasound-guided vs conventional venous puncture for atrial fibrillation ablation: the ULYSSES trial
Background and Aims: Vascular access site complications are the most common procedure-related adverse event of atrial fibrillation catheter ablation. Whether ultrasound-guided femoral venous puncture reduces these vascular access complications remains uncertain. Methods: In this investigator-initiated, multicentre, open-label, superiority trial, patients undergoing atrial fibrillation or left atrial tachycardia catheter ablation were randomized to an ultrasound-guided venous puncture strategy (intervention group) or to a conventional venous puncture group guided by palpation (control group). The composite primary outcome was the occurrence of venous access site complications until 30 days after the procedure, defined as arteriovenous fistula, false aneurysm, or access site bleeding requiring intervention or leading to prolonged hospitalization. Secondary endpoints included procedure duration, puncture duration, procedure-related stroke/transient ischaemic attack within 30 days, number of unintended arterial punctures, and number of failed venous access attempts, as well as hospital stay duration. Results: In six centres, 986 patients were randomized. A total of 496 patients were assigned to the ultrasound-guided puncture group, and 490 patients to the conventional puncture group. The trial was stopped for efficacy, following the first interim analysis after enrolment of half of the planned patients. The composite primary outcome occurred in 3 patients (0.6%) in the intervention group and 16 patients (3.3%) in the control group (risk ratio 0.19; 95% confidence interval 0.05–0.63; P = .002). Additionally, ultrasound-guided venous puncture significantly reduced the rate of an unintended arterial puncture (2% vs 16%, P < .0001) and the rate of unsuccessful venous access attempts requiring crossover to the other group (0.2% vs 8.2%, P < .0001). Conclusions: Ultrasound-guided venous access for atrial fibrillation ablation procedures significantly reduced vascular access site complications. ULYSSES ClinicalTrials.gov number: NCT06403527.
- Open Access
- 30 March 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (4)
Same-day discharge after electrophysiological and cardiac implantable electronic device procedures: a clinical consensus statement of the European Heart Rhythm Association (EHRA) and the Association of Cardiovascular Nursing & Allied Professions (ACNAP) of the ESC
Same-day discharge (SDD) following electrophysiology (EP) and cardiac implantable electronic device (CIED) procedures has emerged as a contemporary care model driven by improvements in procedural safety, efficiency, and healthcare resource constraints. Despite growing evidence supporting its safety in selected patients, adoption of SDD across Europe remains heterogeneous. This clinical consensus statement, developed by the European Heart Rhythm Association (EHRA) of the ESC in collaboration with the Association of Cardiovascular Nursing & Allied Professions (ACNAP) of the ESC, provides an evidence-based and practice-oriented framework for the implementation of SDD pathways after EP and CIED interventions. Based on a structured review of contemporary trials, registries, and expert consensus, the document addresses patient selection, peri-procedural management, early complication surveillance, discharge criteria, and post-discharge follow-up. Procedure-specific considerations are provided for catheter ablation and device implantation. This consensus aims to harmonize clinical practice, reduce variability in care, and support the safe and sustainable expansion of SDD across diverse European healthcare systems.
- 30 March 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (4)
Open AccessSame-day discharge after electrophysiological and cardiac implantable electronic device procedures: a clinical consensus statement of the European Heart Rhythm Association (EHRA) and the Association of Cardiovascular Nursing & Allied Professions (ACNAP) of the ESC
Same-day discharge (SDD) following electrophysiology (EP) and cardiac implantable electronic device (CIED) procedures has emerged as a contemporary care model driven by improvements in procedural safety, efficiency, and healthcare resource constraints. Despite growing evidence supporting its safety in selected patients, adoption of SDD across Europe remains heterogeneous. This clinical consensus statement, developed by the European Heart Rhythm Association (EHRA) of the ESC in collaboration with the Association of Cardiovascular Nursing & Allied Professions (ACNAP) of the ESC, provides an evidence-based and practice-oriented framework for the implementation of SDD pathways after EP and CIED interventions. Based on a structured review of contemporary trials, registries, and expert consensus, the document addresses patient selection, peri-procedural management, early complication surveillance, discharge criteria, and post-discharge follow-up. Procedure-specific considerations are provided for catheter ablation and device implantation. This consensus aims to harmonize clinical practice, reduce variability in care, and support the safe and sustainable expansion of SDD across diverse European healthcare systems.
- Open Access
- 1 December 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (12)
Cardiac implantable electronic device upgrades and downgrades: a Clinical Consensus Statement of the European Heart Rhythm Association (EHRA) of the ESC, the Asia Pacific Heart Rhythm Association (APHRS), Canadian Heart Rhythm Society (CHRS), Heart Rhythm Society (HRS), and the Latin American Heart Rhythm Society (LAHRS)
Cardiac implantable electronic device upgrade and downgrade procedures are increasingly being performed. Whilst the most appropriate guideline-recommended device may have been followed during a patient's initial procedure, the requirements of patients can change over time. This could be due to worsening of cardiac function due to detrimental effects of pacing itself or the diagnosis, development, or progression of another cardiac comorbidity. Device downgrades are also performed when a patient's clinical state changes and are often considered in patients with increased frailty and comorbidity. This clinical consensus statement aims to provide a framework for screening patients for device upgrade, pre-procedural planning considerations, available procedural strategies, namely a summary of techniques and approaches for vascular access, including ipsilateral and contralateral options, and a framework for when extraction to gain access may be appropriate. The document also provides advice on how to frame an ethical discussion with patients and carers on available options.
- 1 December 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (12)
Open AccessCardiac implantable electronic device upgrades and downgrades: a Clinical Consensus Statement of the European Heart Rhythm Association (EHRA) of the ESC, the Asia Pacific Heart Rhythm Association (APHRS), Canadian Heart Rhythm Society (CHRS), Heart Rhythm Society (HRS), and the Latin American Heart Rhythm Society (LAHRS)
Cardiac implantable electronic device upgrade and downgrade procedures are increasingly being performed. Whilst the most appropriate guideline-recommended device may have been followed during a patient's initial procedure, the requirements of patients can change over time. This could be due to worsening of cardiac function due to detrimental effects of pacing itself or the diagnosis, development, or progression of another cardiac comorbidity. Device downgrades are also performed when a patient's clinical state changes and are often considered in patients with increased frailty and comorbidity. This clinical consensus statement aims to provide a framework for screening patients for device upgrade, pre-procedural planning considerations, available procedural strategies, namely a summary of techniques and approaches for vascular access, including ipsilateral and contralateral options, and a framework for when extraction to gain access may be appropriate. The document also provides advice on how to frame an ethical discussion with patients and carers on available options.
- Open Access
- 7 October 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (10)
Influence of proton pump inhibitors on the incidence and clinical course of oesophageal fistula following catheter ablation for atrial fibrillation: a subanalysis of the POTTER-AF study
- 7 October 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (10)
Open AccessInfluence of proton pump inhibitors on the incidence and clinical course of oesophageal fistula following catheter ablation for atrial fibrillation: a subanalysis of the POTTER-AF study
- 17 December 2024
- Published by Wolters Kluwer Health in Circulation
- Vol. 150 (25) , 2007-2018
Ablation Strategies for Repeat Procedures in Atrial Fibrillation Recurrences Despite Durable Pulmonary Vein Isolation: The Prospective Randomized ASTRO AF Multicenter Trial
BACKGROUND: Ablation strategies for patients with symptomatic atrial fibrillation and isolated pulmonary veins vary and their effects on arrhythmia recurrence remain unclear. A prospective randomized German multicenter trial sought to compare 2 ablation strategies in this patient cohort. METHODS: Patients with atrial fibrillation despite durable pulmonary vein isolation were randomly assigned at 7 centers to undergo low-voltage area ablation using 3-dimensional mapping and irrigated radiofrequency current ablation (group A) or empirical left atrial appendage isolation (LAAI) using the cryoballoon followed by staged interventional left atrial appendage closure (group B). The primary end point was freedom from atrial tachyarrhythmias between 91 and 365 days after index ablation. The study was powered for superiority of LAAI compared with low-voltage area. RESULTS: Patients (40% women; mean age, 68.8±8 years) with paroxysmal (32%) or persistent atrial fibrillation (68%) were randomized to undergo low-voltage area ablation (n=79) or cryoballoon-guided LAAI (n=82). After a planned interim analysis, enrollment was halted for futility on January 10, 2023. In the LAAI group, 77 of 82 left atrial appendages were successfully isolated with subsequent left atrial appendage closure in 57 patients. Procedure-related complications occurred in 4 (5%) and 11 (13.5%) patients in group A and B, respectively ( P =0.10). The median follow-up was 367 days (interquartile range, 359–378). The Kaplan-Meier point estimate for freedom from atrial tachyarrhythmias was 51.7% (CI, 40.9%–65.4%) for group A and 55.5% (CI, 44.4%–69.2%; P =0.8069) for group B. CONCLUSIONS: The current study did not detect superiority of cryoballoon-guided LAAI over low-voltage area ablation in patients with atrial fibrillation despite durable PVI. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04056390.
- 17 December 2024
- Published by Wolters Kluwer Health in Circulation
- Vol. 150 (25) , 2007-2018
Ablation Strategies for Repeat Procedures in Atrial Fibrillation Recurrences Despite Durable Pulmonary Vein Isolation: The Prospective Randomized ASTRO AF Multicenter Trial
BACKGROUND: Ablation strategies for patients with symptomatic atrial fibrillation and isolated pulmonary veins vary and their effects on arrhythmia recurrence remain unclear. A prospective randomized German multicenter trial sought to compare 2 ablation strategies in this patient cohort. METHODS: Patients with atrial fibrillation despite durable pulmonary vein isolation were randomly assigned at 7 centers to undergo low-voltage area ablation using 3-dimensional mapping and irrigated radiofrequency current ablation (group A) or empirical left atrial appendage isolation (LAAI) using the cryoballoon followed by staged interventional left atrial appendage closure (group B). The primary end point was freedom from atrial tachyarrhythmias between 91 and 365 days after index ablation. The study was powered for superiority of LAAI compared with low-voltage area. RESULTS: Patients (40% women; mean age, 68.8±8 years) with paroxysmal (32%) or persistent atrial fibrillation (68%) were randomized to undergo low-voltage area ablation (n=79) or cryoballoon-guided LAAI (n=82). After a planned interim analysis, enrollment was halted for futility on January 10, 2023. In the LAAI group, 77 of 82 left atrial appendages were successfully isolated with subsequent left atrial appendage closure in 57 patients. Procedure-related complications occurred in 4 (5%) and 11 (13.5%) patients in group A and B, respectively ( P =0.10). The median follow-up was 367 days (interquartile range, 359–378). The Kaplan-Meier point estimate for freedom from atrial tachyarrhythmias was 51.7% (CI, 40.9%–65.4%) for group A and 55.5% (CI, 44.4%–69.2%; P =0.8069) for group B. CONCLUSIONS: The current study did not detect superiority of cryoballoon-guided LAAI over low-voltage area ablation in patients with atrial fibrillation despite durable PVI. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04056390.
- Open Access
- 2 August 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 8 (8) , ytae369
High-density multipolar mapping facilitating ablation of atypical atrial flutter: the power of ‘more mapping less ablation’
A 79-year-old female patient presented to the emergency care unit with dyspnoea, palpitations, and weakness. In December 2021, persistent atrial fibrillation (AF) was treated by cryoballoon-based pulmonary vein (PV) isolation. A second catheter ablation procedure (3D mapping and radiofrequency ablation) was conducted, and the right PVs were reisolated; a box lesion and an anterior line were deployed in March 2022. The current electrocardiogram shows atypical atrial flutter. A third catheter ablation procedure was planned. Here, the clinical tachycardia was apparent (cycle length = 290 ms). One decapolar catheter was positioned in the coronary sinus (CS) showing a distal to proximal activation sequence. Utilizing entrainment manoeuvres from the left atrial appendage, distal and proximal CS catheter, and anterior and posterior walls, atypical left atrial (LA) flutter was suggested. A 3D electroanatomic LA reconstruction (CARTO 3 V7; Biosense Webster) was performed via high-density mapping with an octaspline multi-electrode catheter and COHERENT module (Biosense Webster) covering the whole cycle lengths of the tachycardia.1 A roof-depending macroreentrant tachycardia with a critical isthmus at the posterior wall was demonstrated (Figure 1; Supplementary material online , Video S1), suggesting a recovery of the previously deployed roof line and posterior line and therefore ‘man-made’ tachycardia. Utilizing the QDOT Micro ablation catheter (Biosense Webster) vHP-SD (90 W, 4 s; QMODE + mode) ablation at the posterior wall terminated the tachycardia after 0.6 s.2,3 A roof line and a posterior line were deployed, reisolating the posterior wall. Additional applications were deployed to block the anterior line which was found to be recovered after initial block. Block of the all lines was verified by traditional pacing manoeuvres via OCTARAY catheter from the LA appendage as well as distal and proximal CS and checking all lines for double potentials along the lines. Programmed stimulation was performed to test re-inducibility. A total of 37 vHP-SD applications were deployed with a total ablation time of 2 min and 22 s and a procedure time of 60 min. No peri-procedural complications occurred. The patient was discharged from the hospital on the next day, and in mid-term follow-up up to 6 months, there was no clinical relevant and detectable recurrence of AF or atypical flutter.
- 2 August 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 8 (8) , ytae369
Open AccessHigh-density multipolar mapping facilitating ablation of atypical atrial flutter: the power of ‘more mapping less ablation’
A 79-year-old female patient presented to the emergency care unit with dyspnoea, palpitations, and weakness. In December 2021, persistent atrial fibrillation (AF) was treated by cryoballoon-based pulmonary vein (PV) isolation. A second catheter ablation procedure (3D mapping and radiofrequency ablation) was conducted, and the right PVs were reisolated; a box lesion and an anterior line were deployed in March 2022. The current electrocardiogram shows atypical atrial flutter. A third catheter ablation procedure was planned. Here, the clinical tachycardia was apparent (cycle length = 290 ms). One decapolar catheter was positioned in the coronary sinus (CS) showing a distal to proximal activation sequence. Utilizing entrainment manoeuvres from the left atrial appendage, distal and proximal CS catheter, and anterior and posterior walls, atypical left atrial (LA) flutter was suggested. A 3D electroanatomic LA reconstruction (CARTO 3 V7; Biosense Webster) was performed via high-density mapping with an octaspline multi-electrode catheter and COHERENT module (Biosense Webster) covering the whole cycle lengths of the tachycardia.1 A roof-depending macroreentrant tachycardia with a critical isthmus at the posterior wall was demonstrated (Figure 1; Supplementary material online , Video S1), suggesting a recovery of the previously deployed roof line and posterior line and therefore ‘man-made’ tachycardia. Utilizing the QDOT Micro ablation catheter (Biosense Webster) vHP-SD (90 W, 4 s; QMODE + mode) ablation at the posterior wall terminated the tachycardia after 0.6 s.2,3 A roof line and a posterior line were deployed, reisolating the posterior wall. Additional applications were deployed to block the anterior line which was found to be recovered after initial block. Block of the all lines was verified by traditional pacing manoeuvres via OCTARAY catheter from the LA appendage as well as distal and proximal CS and checking all lines for double potentials along the lines. Programmed stimulation was performed to test re-inducibility. A total of 37 vHP-SD applications were deployed with a total ablation time of 2 min and 22 s and a procedure time of 60 min. No peri-procedural complications occurred. The patient was discharged from the hospital on the next day, and in mid-term follow-up up to 6 months, there was no clinical relevant and detectable recurrence of AF or atypical flutter.