Hidetoshi Ishibashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Hidetoshi Ishibashi has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Norihisa Miki
Department of Mechanical Engineering, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan
2 shared publications - Yoshihiko Kanno
Department of Nephrology, Tokyo Medical University, Tokyo, Japan
2 shared publications - Akio Yasukawa
Kamishakujii Animal Hospital, 1-4-13 Sekimachi-Higashi, Nerima-ku, Tokyo 177-0052, Japan
1 shared publication - Hajime Yamanaka
Department of Animal Models for Human Disease, National Institute of Neuroscience, National Center for Neurology and Psychiatry
1 shared publication Hideyuki Motohashi
Tokyo Medical University, Tokyo, Japan
1 shared publication- Katsuki Nakamura
Cognitive Neuroscience Section, Primate Research Institute, Kyoto University, Inuyama, Japan
1 shared publication
Latest Publications
- 18 December 2024
- Published by SAGE Publications in Laboratory Animals
- Vol. 59 (2) , 272-275
Preceding sevoflurane inhalation in rats reduces the stress of intraperitoneal injection both in inexperienced experimenters and subject rats
In this study, we found that sevoflurane inhalation in rats prior to intraperitoneal injection decreased stress in both inexperienced experimenters and subject rats. Inexperienced experimenters anaesthetised male Sprague Dawley rats by intraperitoneal injection of anaesthetics, with or without preceding sevoflurane inhalation. Analysis using a visual analogue scale indicated that participating experimenters felt less stress when they performed intraperitoneal injections on rats after subjecting them to sevoflurane inhalation than when performing intraperitoneal injections alone. Plasma corticosterone concentrations of the anaesthetised subject rats were lower when the intraperitoneal injection was preceded by sevoflurane inhalation. Thus, our results demonstrated that it is advisable for inexperienced experimenters, until they gain confidence with experience, to perform sevoflurane inhalation on male rats before intraperitoneal injections.
- 18 December 2024
- Published by SAGE Publications in Laboratory Animals
- Vol. 59 (2) , 272-275
Preceding sevoflurane inhalation in rats reduces the stress of intraperitoneal injection both in inexperienced experimenters and subject rats
In this study, we found that sevoflurane inhalation in rats prior to intraperitoneal injection decreased stress in both inexperienced experimenters and subject rats. Inexperienced experimenters anaesthetised male Sprague Dawley rats by intraperitoneal injection of anaesthetics, with or without preceding sevoflurane inhalation. Analysis using a visual analogue scale indicated that participating experimenters felt less stress when they performed intraperitoneal injections on rats after subjecting them to sevoflurane inhalation than when performing intraperitoneal injections alone. Plasma corticosterone concentrations of the anaesthetised subject rats were lower when the intraperitoneal injection was preceded by sevoflurane inhalation. Thus, our results demonstrated that it is advisable for inexperienced experimenters, until they gain confidence with experience, to perform sevoflurane inhalation on male rats before intraperitoneal injections.
- Open Access
Development of a DSM test battery to determine depression-like marmoset
Depression is a serious and high-incidence mental disorder that can lead to suicide. Despite much depression research using humans and rodents to date, it has been difficult to completely overcome depression and elucidate its etiology. Marmoset monkeys have been utilized to study neuropsychiatric disorders in recent years. Since the clinical diagnostic criteria for psychiatric disorders are mainly based on multiple behavioral changes, test battery systems, a multifaceted and comprehensive strategy, are applied to depression research. Here, we devised a test battery with six tests to investigate depression-like symptoms corresponding to clinical criteria and set criteria for a test indicator-based judgment. We did a usability confirmation experiment using a drug and judged three of nine marmosets as depression-like. This rate is comparable with the incidence rate of human patients; i.e., 10-30% of patients who received reserpine treatment suffer from depression. Thus, we propose the test battery we constructed in this study will contribute to the study of depression.
Open AccessDevelopment of a DSM test battery to determine depression-like marmoset
Depression is a serious and high-incidence mental disorder that can lead to suicide. Despite much depression research using humans and rodents to date, it has been difficult to completely overcome depression and elucidate its etiology. Marmoset monkeys have been utilized to study neuropsychiatric disorders in recent years. Since the clinical diagnostic criteria for psychiatric disorders are mainly based on multiple behavioral changes, test battery systems, a multifaceted and comprehensive strategy, are applied to depression research. Here, we devised a test battery with six tests to investigate depression-like symptoms corresponding to clinical criteria and set criteria for a test indicator-based judgment. We did a usability confirmation experiment using a drug and judged three of nine marmosets as depression-like. This rate is comparable with the incidence rate of human patients; i.e., 10-30% of patients who received reserpine treatment suffer from depression. Thus, we propose the test battery we constructed in this study will contribute to the study of depression.
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2021, 5051-5054
Design of microfluidic channels to prevent negative filtration in implantable hemofiltration devices
In order to improve the quality of life of dialysis patients, our group have been developing an implantable hemofiltration device (IHFD) composed of multiple layers of dialysis membranes and microfluidic channels. To improve the hemodialysis performance of IHFD, preventing the negative filtration, which is caused by the oncotic pressure of blood, is mandatory. In this study, we fabricated IHFDs with five different microchannel designs and experimentally investigated the performance of each device in in vitro experiment. In addition, the successful IHFD was further evaluated by ex vivo experiments with a beagle dog. The experiments verified the effectiveness of the microchannel design, which will be used for the IHFD for in vivo experiments with pigs in the future.
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2021, 5051-5054
Design of microfluidic channels to prevent negative filtration in implantable hemofiltration devices
In order to improve the quality of life of dialysis patients, our group have been developing an implantable hemofiltration device (IHFD) composed of multiple layers of dialysis membranes and microfluidic channels. To improve the hemodialysis performance of IHFD, preventing the negative filtration, which is caused by the oncotic pressure of blood, is mandatory. In this study, we fabricated IHFDs with five different microchannel designs and experimentally investigated the performance of each device in in vitro experiment. In addition, the successful IHFD was further evaluated by ex vivo experiments with a beagle dog. The experiments verified the effectiveness of the microchannel design, which will be used for the IHFD for in vivo experiments with pigs in the future.
- Open Access
- 20 August 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (8) , 992
Pump-Free Microfluidic Hemofiltration Device
Hemofiltration removes water and small molecules from the blood via nanoporous filtering membranes. This paper discusses a pump-free hemofiltration device driven by the pressure difference between the artery and the vein. In the design of the filtering device, oncotic pressure needs to be taken into consideration. Transmembrane pressure (TMP) determines the amount and direction of hemofiltration, which is calculated by subtracting the oncotic pressure from the blood pressure. Blood pressure decreases as the channels progress from the inlet to the outlet, while oncotic pressure increases slightly since no protein is removed from the blood to the filtrate in hemofiltration. When TMP is negative, the filtrate returns to the blood, i.e., backfiltration takes place. A small region of the device with negative TMP would thus result in a small amount of or even zero filtrates. First, we investigated this phenomenon using in vitro experiments. We then designed a hemofiltration system taking backfiltration into consideration. We divided the device into two parts. In the first part, the device has channels for the blood and filtrate with a nanoporous membrane. In the second part, the device does not have channels for filtration. This design ensures TMP is always positive in the first part and prevents backfiltration. The concept was verified using in vitro experiments and ex vivo experiments in beagle dogs. Given the simplicity of the device without pumps or electrical components, the proposed pump-free hemofiltration device may prove useful for either implantable or wearable hemofiltration.
- 20 August 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (8) , 992
Open AccessPump-Free Microfluidic Hemofiltration Device
Hemofiltration removes water and small molecules from the blood via nanoporous filtering membranes. This paper discusses a pump-free hemofiltration device driven by the pressure difference between the artery and the vein. In the design of the filtering device, oncotic pressure needs to be taken into consideration. Transmembrane pressure (TMP) determines the amount and direction of hemofiltration, which is calculated by subtracting the oncotic pressure from the blood pressure. Blood pressure decreases as the channels progress from the inlet to the outlet, while oncotic pressure increases slightly since no protein is removed from the blood to the filtrate in hemofiltration. When TMP is negative, the filtrate returns to the blood, i.e., backfiltration takes place. A small region of the device with negative TMP would thus result in a small amount of or even zero filtrates. First, we investigated this phenomenon using in vitro experiments. We then designed a hemofiltration system taking backfiltration into consideration. We divided the device into two parts. In the first part, the device has channels for the blood and filtrate with a nanoporous membrane. In the second part, the device does not have channels for filtration. This design ensures TMP is always positive in the first part and prevents backfiltration. The concept was verified using in vitro experiments and ex vivo experiments in beagle dogs. Given the simplicity of the device without pumps or electrical components, the proposed pump-free hemofiltration device may prove useful for either implantable or wearable hemofiltration.
- Open Access
- 1 January 2016
- Published by Japanese Society of Veterinary Science in Journal of Veterinary Medical Science
- Vol. 78 (2) , 317-319
More effective induction of anesthesia using midazolam-butorphanol-ketamine-sevoflurane compared with ketamine-sevoflurane in the common marmoset monkey (Callithrix jacchus)
The common marmoset has been increasingly used for research in the biomedical field; however, there is little information available regarding effective methods of anesthesia in this species. This study retrospectively analyzed 2 regimens of anesthesia induction: intramuscular injection of ketamine followed by inhalation of 5% sevoflurane, and intramuscular injection of midazolam, butorphanol and ketamine followed by inhalation of 5% sevoflurane. Anesthetic depth did not reach the surgical anesthesia stage in 7 out of 99 animals receiving the former regimen, whereas there were only 2 such animals out of 273 receiving the latter regimen. The latter regimen, when followed by maintenance anesthesia with 3% sevoflurane inhalation, was successfully used in various nociceptive procedures. These results indicate that the injection of a combination of midazolam, butorphanol and ketamine followed by inhalation of a high concentration of sevoflurane is effective for anesthesia induction in marmosets.
- 1 January 2016
- Published by Japanese Society of Veterinary Science in Journal of Veterinary Medical Science
- Vol. 78 (2) , 317-319
Open AccessMore effective induction of anesthesia using midazolam-butorphanol-ketamine-sevoflurane compared with ketamine-sevoflurane in the common marmoset monkey (Callithrix jacchus)
The common marmoset has been increasingly used for research in the biomedical field; however, there is little information available regarding effective methods of anesthesia in this species. This study retrospectively analyzed 2 regimens of anesthesia induction: intramuscular injection of ketamine followed by inhalation of 5% sevoflurane, and intramuscular injection of midazolam, butorphanol and ketamine followed by inhalation of 5% sevoflurane. Anesthetic depth did not reach the surgical anesthesia stage in 7 out of 99 animals receiving the former regimen, whereas there were only 2 such animals out of 273 receiving the latter regimen. The latter regimen, when followed by maintenance anesthesia with 3% sevoflurane inhalation, was successfully used in various nociceptive procedures. These results indicate that the injection of a combination of midazolam, butorphanol and ketamine followed by inhalation of a high concentration of sevoflurane is effective for anesthesia induction in marmosets.