Xing Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xing Yang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Juncai Wang
School of Emergency Management and Safety Engineering, China University of Mining and Technology, Beijing 100083, China
1 shared publication - Liusuo Wu
State Grid Electric Power Research Institute CO., LTD., Nanjing 211106, China
1 shared publication - Peng Chen
School of Emergency Management and Safety Engineering, China University of Mining and Technology (Beijing), Beijing, China
1 shared publication - Ruibang Sun
School of Emergency Management and Safety Engineering, China University of Mining and Technology, Beijing 100083, China
1 shared publication
Latest Publications
- Open Access
Experimental Study on Axial Temperature Profile of Jet Fire of Oil-Filled Equipment in Substation
With the widespread use of substations around the world, oil jet fire accidents from transformer oil-filled equipment in substations caused by faults have occurred from time to time. In this paper, a series of transformer oil jet fire experiments are carried out by changing the external heat source (30 cm and 40 cm) and the inner diameter of the container (5 cm, 8 cm and 10 cm) to study the axial centerline temperature distribution of the transformer oil jet fire plume of the transformer oil-filled equipment in the substation. The experiment uses K-type thermocouple, electronic balance and CCD to measure and assess the temperature distribution of the axial centerline of the fire plume of the transformer oil jet. The result demonstrates that the axial centerline temperature of the fire plume increases with the external heat release rate and the inner diameter of the container. In addition, a novel axial temperature distribution prediction model of the transformer oil jet fire plume is established. This model can effectively predict the oil jet fire plume temperature of transformer oil- filling equipment in substations, and provide help for substation fire control.
Open AccessExperimental Study on Axial Temperature Profile of Jet Fire of Oil-Filled Equipment in Substation
With the widespread use of substations around the world, oil jet fire accidents from transformer oil-filled equipment in substations caused by faults have occurred from time to time. In this paper, a series of transformer oil jet fire experiments are carried out by changing the external heat source (30 cm and 40 cm) and the inner diameter of the container (5 cm, 8 cm and 10 cm) to study the axial centerline temperature distribution of the transformer oil jet fire plume of the transformer oil-filled equipment in the substation. The experiment uses K-type thermocouple, electronic balance and CCD to measure and assess the temperature distribution of the axial centerline of the fire plume of the transformer oil jet. The result demonstrates that the axial centerline temperature of the fire plume increases with the external heat release rate and the inner diameter of the container. In addition, a novel axial temperature distribution prediction model of the transformer oil jet fire plume is established. This model can effectively predict the oil jet fire plume temperature of transformer oil- filling equipment in substations, and provide help for substation fire control.