    Evaluating the Harmonic Effects on the Thermal Performance of a Power Transformer

    by Mohamed S. Seddik, Magdy B. Eteiba, Jehan Shazly

    Harmonics in the power grid contribute to increased power losses in both the core and windings of power transformers. These losses lead to abnormal rises in temperature causing overheating and reduce the efficiency of the transformer. If the losses and temperature exceed the values set during the design stage for linear load conditions, it can damage the transformer’s insulating materials and shorten its lifespan. To assess the thermal impact of power system harmonics on transformers under steady-state and transient conditions, the rated losses and harmonic losses of the transformer are calculated. These losses are then inputted into a developed thermal 3D finite element method (FEM) performance model to determine the temperature distribution of transformer components. The numerical results from the thermal model will be compared with data from a Hyundai test report and real measurements from Egypt’s Kureimat power plant, specifically a 750 MW combined cycle power plant. The thermal modeling is focused on a step-up (16.5/240 kV), 240 ± 4 × 2.5%, 180/240/300 MVA power transformer operating in ONAN, ONAF1, and ONAF2 modes. This paper shows that the developed model aligns closely with actual measurements and the HYUNDAI test report. The loss calculations reveal that the discrepancy in total losses, with and without accounting for harmonics, becomes more pronounced as the load increases. Using this model, the presence of grid harmonics results in a higher temperature distribution across transformer components, leading to an increase in the hot spot temperature.


  • Open Access

    Thermal Analysis of Power Transformer Using 2D and 3D Finite Element Method

    by Mohamed S. Seddik, Jehan Shazly, Magdy B. Eteiba

    An accurate simulation and computational analysis of temperature distribution in large power transformers used in power plants is crucial during both the design and operational phases. This study introduces a thermal modeling analysis encompassing two- and three-dimensional (2D and 3D) approaches for power transformers. The mathematical model for heat diffusion follows the Finite Element Method (FEM) approach. Validation of the computed results involves comparing them against measurements from Hyundai’s test report for both 2D and 3D models, aiming to identify the most effective solution. Additionally, the thermal dynamics of power transformers under diverse operational conditions, specifically oil-immersed ones, are examined. The efficacy of this model is confirmed through testing on a step-up transformer at Kureimat station in Egypt, with specifications including three-phase, 50 Hz, 16.5/240 KV, nine taps, and cooling type (ONAN/ONAF1/ONAF2).


  • Open Access

    Thermal analysis of high‐voltage cables with several types of insulation for different configurations in the presence of harmonics

    by Jehan H. Shazly, Mohamed A. Mostafa, Doaa K. Ibrahim, Essam E. Abo El Zahab

    In this contribution, the three‐phase underground cable is modelled using COMSOL Multiphysics software to evaluate the steady state and transient thermal performances. Finite element technique is applied using the heat conduction equation to study the temperature distributions in power cables components and the surrounding environment for both linear and non‐linear loads. A real case study of 220 kV, 340 MVA three‐phase single core copper cables insulated by XLPE is studied. Other types of insulation such as oil, and SF6 gas and their contributions of convection and radiation are investigated at trefoil and flat configurations. The loading capability under different ambient conditions for average moisture soil and dry soil with low‐moisture content are also evaluated taking into account the unfavourable effect of dry zones formation. Moreover, the challenge of predicting the accurate thermal performance and estimating the required derating factor in the presence of odd harmonics is considered. The effect of the change of the frequency spectrum of the non‐linear load current by involving different simultaneous harmonic orders for the same total harmonic distortion is extensively investigated for both flat and trefoil configurations. It is concluded that all harmonics contributions should be considered, to accurately calculate the required cable derating.