MJMyra Kurosu Jalil

Myra Kurosu Jalil

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Myra Kurosu Jalil has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A lung tumor-on-a-chip model recapitulates the effect of hypoxia on radiotherapy response and FDG-PET imaging

    by Rohollah Nasiri, Myra Kurosu Jalil, Veronica Ibanez Gaspar, Andrea Sofia Flores Perez, Hieu Thi Minh Nguyen, Syamantak Khan, Sindy K. Y. Tang, Yunzhi Peter Yang, Guillem Pratx

    A microfluidic tumor-on-a-chip platform reveals hypoxia-induced radioresistance and metabolic shifts via integrated PET imaging.


  • Open Access

    A Lung Tumor-on-a-Chip Model Recapitulates the Effect of Hypoxia on Radiotherapy Response and FDG-PET Imaging

    by Rohollah Nasiri, Myra Kurosu Jalil, Veronica Ibanez Gaspar, Andrea Sofia Flores Perez, Hieu Thi Minh Nguyen, Syamantak Khan, Sindy Ky Tang, Yunzhi Peter Yang, Guillem Pratx

    Most solid tumors contain regions of hypoxia that pose a significant challenge to the efficacy of radiation therapy. This study introduces a novel 3D lung tumor-on-a-chip (ToC) model designed to replicate the hypoxic tumor microenvironment in vitro while also providing a platform for clinically relevant interventions such as radiotherapy and positron emission tomography (PET) imaging. To simulate the heterogeneous oxygen distribution found in tumors, the ToC model incorporates an oxygen gradient achieved through a straightforward chemical oxygen scavenging system. A unique innovation of this device is the integration of a thin scintillator plate, which enables high-resolution radioluminescence microscopy imaging of tumor metabolism under hypoxia and normoxia conditions using clinically approved PET tracers such as fluorodeoxyglucose (FDG). The response of this hypoxic model to radiation therapy (10 Gy X-ray) demonstrated ∼4-fold higher radioresistance compared to the normoxic ToC model, as assessed by colony formation potential. Additionally, DNA damage observed in the normoxic ToC model was ∼5-fold higher than that in the hypoxic model. Furthermore, the metabolic consumption of glucose was found to mirror the localization of hypoxia, validating the use of this biomarker for planning radiation therapy. The integration of high-resolution radionuclide imaging within ToC models enables on-chip PET imaging and facilitates oncology research and discovery, offering innovative capabilities for the preclinical testing of novel cancer therapies in a clinically relevant environment.

  • Open Access

    Hydrodynamic dissection of single cells in a microfluidic system

    by Rajorshi Paul, Kevin S. Zhang, Myra Kurosu Jalil, Nicolas Castaño, Sungu Kim, Sindy Kam Yan Tang

    Stentor coeruleus , a single-cell ciliated protozoan, is a model organism for wound healing and regeneration studies. Despite Stentor ’s large size (up to 2 mm in extended state), microdissection of Stentor remains challenging. In this work, we describe a hydrodynamic cell splitter, consisting of a cross junction, capable of splitting Stentor cells in a non-contact manner at a high throughput of ∼500 cells/min under continuous operation. Introduction of asymmetry in the flow field at the cross junction leads to asymmetric splitting of the cells to generate cell fragments as small as ∼8.5 times the original cell size. Characterization of cell fragment viability shows reduced 5-day survival as fragment size decreases and as the extent of hydrodynamic stress imposed on the fragments increases. Our results suggest that cell fragment size and composition, as well as mechanical stress, play important roles in the long-term repair of Stentor cells and warrant further investigations. Nevertheless, the hydrodynamic splitter can be useful for studying phenomena immediately after cell splitting, such as the closure of wounds in the plasma membrane which occurs on the order of 100 – 1000 seconds in Stentor .

  • Open Access

    Fabrication of 3D Micro-Blades for the Cutting of Biological Structures in a Microfluidic Guillotine

    by Saisneha Koppaka, Kevin S. Zhang, Myra Kurosu Jalil, Lucas R. Blauch, Sindy K. Y. Tang

    Micro-blade design is an important factor in the cutting of single cells and other biological structures. This paper describes the fabrication process of three-dimensional (3D) micro-blades for the cutting of single cells in a microfluidic “guillotine” intended for fundamental wound repair and regeneration studies. Our microfluidic guillotine consists of a fixed 3D micro-blade centered in a microchannel to bisect cells flowing through. We show that the Nanoscribe two-photon polymerization direct laser writing system is capable of fabricating complex 3D micro-blade geometries. However, structures made of the Nanoscribe IP-S resin have low adhesion to silicon, and they tend to peel off from the substrate after at most two times of replica molding in poly(dimethylsiloxane) (PDMS). Our work demonstrates that the use of a secondary mold replicates Nanoscribe-printed features faithfully for at least 10 iterations. Finally, we show that complex micro-blade features can generate different degrees of cell wounding and cell survival rates compared with simple blades possessing a vertical cutting edge fabricated with conventional 2.5D photolithography. Our work lays the foundation for future applications in single cell analyses, wound repair and regeneration studies, as well as investigations of the physics of cutting and the interaction between the micro-blade and biological structures.


  • Open Access

    Fabrication of 3D Micro-Blades for the Cutting of Biological Structures in a Microfluidic Guillotine

    by Saisneha Koppaka, Kevin Zhang, Myra Kurosu Jalil, Lucas Blauch, Sindy Tang

    Micro-blade design is an important factor in the cutting of single cells and other biological structures. This paper describes the fabrication process of three dimensional (3D) micro-blades for the cutting of single cells in a microfluidic “guillotine” intended for fundamental wound repair and regeneration studies. Our microfluidic guillotine consists of a fixed 3D micro-blade centered in a microchannel to bisect cells flowing through. We show that the Nanoscribe two-photon polymerization direct laser writing system is capable of fabricating complex 3D micro-blade geometries. However, structures made of the Nanoscribe IP-S resin have low adhesion to silicon, and they tend to peel off from the substrate after at most two times of replica molding in poly(dimethylsiloxane) (PDMS). Our work demonstrates that the use of a secondary mold replicates Nanoscribe printed features faithfully for at least 10 iterations. Finally, we show that complex micro-blade features can generate different degrees of cell wounding and cell survival rates compared with simple blades possessing a vertical cutting edge fabricated with conventional 2.5D photolithography. Our work lays the foundation for future applications in single cell analyses, wound repair and regeneration studies, as well as investigations of the physics of cutting and the interaction between the micro-blade and biological structures.