Jaewoo Chung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jaewoo Chung has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Byung-Yong Ko
2 shared publications- Byungyong Ko
Dept. of Urban System Engineering Gyeongsang National University
2 shared publications - Myoung Eun Lee
Future Convergence Technology Research Institute Gyeongsang National University
2 shared publications Byeong-Cheol Kim
1 shared publication- Haenam Jang
Department of Energy Engineering Gyeongsang National University Jinju Republic of Korea
1 shared publication - Hyunchul Oh
Ulsan National Institute of Science and Technology (UNIST)
1 shared publication
Latest Publications
- Open Access
- 28 February 2026
- Published by Korea Institute of Fire Science and Engineering in Fire Science and Engineering
- Vol. 40 (1) , 49-58
Priority Determination of Response Strategies for Electric Vehicle Fires in Underground Parking Lots Using an Analytic Hierarchy Process (AHP)
With the rapid expansion of electric vehicles (EVs), the probability of fires in underground parking lots and the risk of complex damage have increased, necessitating the establishment of systematic and priority-based response strategies. Previous studies utilizing full-scale experiments simulating EV fires in underground parking lots confirmed that overhead sprinkler systems alone can effectively block the spread of fires to adjacent vehicles. This study analyzes the relative importance of EV fire response strategies derived from focus group interviews (FGIs) with four experts. Survey results from 38 relevant experts showed a consistency ratio (CR) of 0.027, indicating high reliability. Among upper-level factors, life safety and evacuation strategies were evaluated as the most critical with a weight of 0.410. In the global weight analysis of the sub-factors, emergency alarm system (EAS) recorded the highest priority (0.171). Additionally, the evacuation route design (ERD) and fire detection speed (FDS) were emphasized as key elements. These results align with previous findings, suggesting that response systems centered on life safety should be prioritized. Furthermore, this study demonstrates that overhead sprinkler systems can serve as critical facilities for the initial response to EV fires. The findings of this study provide foundational evidence for the development of policies and technical strategies related to EV fire response.
- 28 February 2026
- Published by Korea Institute of Fire Science and Engineering in Fire Science and Engineering
- Vol. 40 (1) , 49-58
Open AccessPriority Determination of Response Strategies for Electric Vehicle Fires in Underground Parking Lots Using an Analytic Hierarchy Process (AHP)
With the rapid expansion of electric vehicles (EVs), the probability of fires in underground parking lots and the risk of complex damage have increased, necessitating the establishment of systematic and priority-based response strategies. Previous studies utilizing full-scale experiments simulating EV fires in underground parking lots confirmed that overhead sprinkler systems alone can effectively block the spread of fires to adjacent vehicles. This study analyzes the relative importance of EV fire response strategies derived from focus group interviews (FGIs) with four experts. Survey results from 38 relevant experts showed a consistency ratio (CR) of 0.027, indicating high reliability. Among upper-level factors, life safety and evacuation strategies were evaluated as the most critical with a weight of 0.410. In the global weight analysis of the sub-factors, emergency alarm system (EAS) recorded the highest priority (0.171). Additionally, the evacuation route design (ERD) and fire detection speed (FDS) were emphasized as key elements. These results align with previous findings, suggesting that response systems centered on life safety should be prioritized. Furthermore, this study demonstrates that overhead sprinkler systems can serve as critical facilities for the initial response to EV fires. The findings of this study provide foundational evidence for the development of policies and technical strategies related to EV fire response.
- Open Access
- 30 June 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (3) , 67-75
Priority Evaluation of Corrosion Mitigation Strategies for Sprinkler Metallic Pipes in Underground Parking Facilities Based on the Analytic Hierarchy Process (AHP)
Underground parking facilities are prone to metal pipe corrosion owing to their high humidity and enclosed conditions, which can reduce the reliability of fire protection systems. This study identified key strategies to address corrosion in sprinkler piping and applied the Analytic Hierarchy Process (AHP) to evaluate their priorities. Five main strategy categories and 15 subfactors were assessed through expert consultation and a survey of 35 fire safety professionals. The analysis revealed a high consistency ratio (CR) of 0.007. The top-priority strategy was “corrosion prevention and early response,” emphasizing the importance of preventive technologies and rapid response systems. Among the sub-factors, “application of preventive technologies” ranked highest, confirming its effectiveness in enhancing system reliability and maintenance efficiency. The results of this study suggest that the priority implementation of corrosion prevention measures and establishment of a rapid response system are essential to ensure the long-term performance and safety of sprinkler-based fire response systems.
- 30 June 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (3) , 67-75
Open AccessPriority Evaluation of Corrosion Mitigation Strategies for Sprinkler Metallic Pipes in Underground Parking Facilities Based on the Analytic Hierarchy Process (AHP)
Underground parking facilities are prone to metal pipe corrosion owing to their high humidity and enclosed conditions, which can reduce the reliability of fire protection systems. This study identified key strategies to address corrosion in sprinkler piping and applied the Analytic Hierarchy Process (AHP) to evaluate their priorities. Five main strategy categories and 15 subfactors were assessed through expert consultation and a survey of 35 fire safety professionals. The analysis revealed a high consistency ratio (CR) of 0.007. The top-priority strategy was “corrosion prevention and early response,” emphasizing the importance of preventive technologies and rapid response systems. Among the sub-factors, “application of preventive technologies” ranked highest, confirming its effectiveness in enhancing system reliability and maintenance efficiency. The results of this study suggest that the priority implementation of corrosion prevention measures and establishment of a rapid response system are essential to ensure the long-term performance and safety of sprinkler-based fire response systems.
- Open Access
- 28 February 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (1) , 67-75
Corrosion Prevention in Sprinkler Metal Pipes using Silicate-based Corrosion Inhibitors and Electrolyzed-Reduced Water
Buildings exceeding a specified size are mandated to install sprinkler systems in underground parking lots to suppress fires until the fire department arrives. However, the metal pipes used in these sprinkler systems are highly susceptible to corrosion, which can lead to rust formation and associated issues, thereby diminishing the reliability of the fire protection system and resulting in significant economic losses for the building. This study examined the corrosion inhibition mechanism of electrolyzed-reduced water and silicate-based corrosion inhibitors via electrochemical analysis. Additionally, their effects on the protection of metal pipes were assessed. After the formation of a protective film by injecting the inhibitors into fire suppression pipes for 72 h, its corrosion prevention performance was evaluated using scanning electron microscopy (SEM), energy-dispersive spectroscopy (EDS), and electrochemical techniques. Results demonstrated that the protective film effectively inhibited corrosion, reduced the corrosion current density, and significantly enhanced the corrosion resistance of the metal pipes, thereby extending their expected service life.
- 28 February 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (1) , 67-75
Open AccessCorrosion Prevention in Sprinkler Metal Pipes using Silicate-based Corrosion Inhibitors and Electrolyzed-Reduced Water
Buildings exceeding a specified size are mandated to install sprinkler systems in underground parking lots to suppress fires until the fire department arrives. However, the metal pipes used in these sprinkler systems are highly susceptible to corrosion, which can lead to rust formation and associated issues, thereby diminishing the reliability of the fire protection system and resulting in significant economic losses for the building. This study examined the corrosion inhibition mechanism of electrolyzed-reduced water and silicate-based corrosion inhibitors via electrochemical analysis. Additionally, their effects on the protection of metal pipes were assessed. After the formation of a protective film by injecting the inhibitors into fire suppression pipes for 72 h, its corrosion prevention performance was evaluated using scanning electron microscopy (SEM), energy-dispersive spectroscopy (EDS), and electrochemical techniques. Results demonstrated that the protective film effectively inhibited corrosion, reduced the corrosion current density, and significantly enhanced the corrosion resistance of the metal pipes, thereby extending their expected service life.
- Open Access
- 31 December 2024
- Published by Korea Institute of Fire Science and Engineering in Fire Science and Engineering
- Vol. 38 (6) , 43-52
Full-Scale Fire Suppression Experiment of a Water-Based Extinguishing System for Electric Vehicle Fire Response
The distribution of electric vehicles (EVs) in South Korea continues to expand owing to government policies aimed at reducing greenhouse-gas emissions and fostering future industries. As of July 2024, 621,000 EVs were registered, with 1.32 fire incidents reported per 10,000 vehicles in 2023. A two-stage experiment was conducted to verify the fire suppression and control performance of the sprinkler and undercarriage sprinkling systems, which are the basic fire safety facilities for responding to EV fires. The experiment also targeted EVs with different battery types and included a lower two-line sprinkling system, which was not used in previous experiments. In the first stage, a domestic EV equipped with pouch-type batteries was tested using the upper sprinkler and lower two-line sprinkling system. In the second stage, a foreign EV equipped with cylindrical batteries was tested using the upper sprinkler and lower one-line sprinkling system. The results showed that in the first and second stages, the battery loss rates were approximately 30%, and 100%, respectively. Although various experimental conditions affected the thermal runaway duration, loss rate, and fire spread to adjacent vehicles, cooling the battery pack using both the upper and lower water-based extinguishing systems delayed thermal runaway and effectively prevented the spread of fire. Notably, the lower sprinkling system showed differences in thermal runaway duration and fire-suppression performance depending on the battery cell type.
- 31 December 2024
- Published by Korea Institute of Fire Science and Engineering in Fire Science and Engineering
- Vol. 38 (6) , 43-52
Open AccessFull-Scale Fire Suppression Experiment of a Water-Based Extinguishing System for Electric Vehicle Fire Response
The distribution of electric vehicles (EVs) in South Korea continues to expand owing to government policies aimed at reducing greenhouse-gas emissions and fostering future industries. As of July 2024, 621,000 EVs were registered, with 1.32 fire incidents reported per 10,000 vehicles in 2023. A two-stage experiment was conducted to verify the fire suppression and control performance of the sprinkler and undercarriage sprinkling systems, which are the basic fire safety facilities for responding to EV fires. The experiment also targeted EVs with different battery types and included a lower two-line sprinkling system, which was not used in previous experiments. In the first stage, a domestic EV equipped with pouch-type batteries was tested using the upper sprinkler and lower two-line sprinkling system. In the second stage, a foreign EV equipped with cylindrical batteries was tested using the upper sprinkler and lower one-line sprinkling system. The results showed that in the first and second stages, the battery loss rates were approximately 30%, and 100%, respectively. Although various experimental conditions affected the thermal runaway duration, loss rate, and fire spread to adjacent vehicles, cooling the battery pack using both the upper and lower water-based extinguishing systems delayed thermal runaway and effectively prevented the spread of fire. Notably, the lower sprinkling system showed differences in thermal runaway duration and fire-suppression performance depending on the battery cell type.
- Open Access
Enhancement of Biogas Production in Anaerobic Digestion Using Microbial Electrolysis Cell Seed Sludge
Anaerobic digestion (AD) can produce renewable energy and reduce carbon emissions, but the energy conversion efficiency is still limited in some waste streams. This study tested the effect of applied voltage removal for microbial electrolysis cells (MECs) treating primary sewage sludge. Two MECs were operated in parallel: a MEC-0.3 V with an applied voltage of 0.3 V and a MEC-OCV with open circuit voltage. Both reactors were inoculated with seed sludge originating from a MEC at 0.3 V applied voltage, and three batch cycles were operated for 36 d. The methane production of the MEC-OCV was 3759 mL/L in the first cycle and 2759 mL/L in the second cycle, which was similar (105% and 103%, respectively) to that of the MEC-0.3 V. However, in the third cycle, the methane production of the MEC-OCV (1762 mL/L) was 38.8% lower than that of the MEC-0.3 V (4545 mL/L). The methane contents in the biogas were 68.6–74.2% from the MEC-OCV, comparable to those from the MEC-0.3 V (66.6–71.1%). These results indicate that not only the MEC-0.3V but also the MEC-OCV outperformed AD in terms of methane yield and productivity, and the promotion using MEC-derived inoculum persisted equally with the MEC-OCV for two batch cycles after removing the applied voltage. Therefore, a MEC operation with cycled power supply may be beneficial in reducing the electric energy usage and improving the biogas production performance, compared to conventional AD.
Open AccessEnhancement of Biogas Production in Anaerobic Digestion Using Microbial Electrolysis Cell Seed Sludge
Anaerobic digestion (AD) can produce renewable energy and reduce carbon emissions, but the energy conversion efficiency is still limited in some waste streams. This study tested the effect of applied voltage removal for microbial electrolysis cells (MECs) treating primary sewage sludge. Two MECs were operated in parallel: a MEC-0.3 V with an applied voltage of 0.3 V and a MEC-OCV with open circuit voltage. Both reactors were inoculated with seed sludge originating from a MEC at 0.3 V applied voltage, and three batch cycles were operated for 36 d. The methane production of the MEC-OCV was 3759 mL/L in the first cycle and 2759 mL/L in the second cycle, which was similar (105% and 103%, respectively) to that of the MEC-0.3 V. However, in the third cycle, the methane production of the MEC-OCV (1762 mL/L) was 38.8% lower than that of the MEC-0.3 V (4545 mL/L). The methane contents in the biogas were 68.6–74.2% from the MEC-OCV, comparable to those from the MEC-0.3 V (66.6–71.1%). These results indicate that not only the MEC-0.3V but also the MEC-OCV outperformed AD in terms of methane yield and productivity, and the promotion using MEC-derived inoculum persisted equally with the MEC-OCV for two batch cycles after removing the applied voltage. Therefore, a MEC operation with cycled power supply may be beneficial in reducing the electric energy usage and improving the biogas production performance, compared to conventional AD.
- 22 September 2021
- Published by Royal Society of Chemistry (RSC) in Materials Chemistry Frontiers
- Vol. 5 (22) , 8018-8024
Chemical affinity-assisted H2 isotope separation using Ca-rich onion-peel-derived nanoporous carbon composite
The current approach of using Ca-rich onion-peel-derived carbon obtained via CO2 physical activation demonstrated hydrogen isotope separation performance better than the conventional cryogenic distillation method.
- 22 September 2021
- Published by Royal Society of Chemistry (RSC) in Materials Chemistry Frontiers
- Vol. 5 (22) , 8018-8024
Chemical affinity-assisted H2 isotope separation using Ca-rich onion-peel-derived nanoporous carbon composite
The current approach of using Ca-rich onion-peel-derived carbon obtained via CO2 physical activation demonstrated hydrogen isotope separation performance better than the conventional cryogenic distillation method.