Byungyong Ko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Byungyong Ko has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Jaewoo Chung
Department of Environmental Engineering, Future Convergence Technology Research Institute, Gyeongsang National University, Jinju 52725, Korea
2 shared publications Jeahyun Lee
1 shared publicationJubong Lee
Dept. of Urban System Engineering Gyeongsang National University
1 shared publicationSanghyun Byun
1 shared publicationSangtae Jeon
1 shared publication
Latest Publications
- Open Access
- 30 June 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (3) , 67-75
Priority Evaluation of Corrosion Mitigation Strategies for Sprinkler Metallic Pipes in Underground Parking Facilities Based on the Analytic Hierarchy Process (AHP)
Underground parking facilities are prone to metal pipe corrosion owing to their high humidity and enclosed conditions, which can reduce the reliability of fire protection systems. This study identified key strategies to address corrosion in sprinkler piping and applied the Analytic Hierarchy Process (AHP) to evaluate their priorities. Five main strategy categories and 15 subfactors were assessed through expert consultation and a survey of 35 fire safety professionals. The analysis revealed a high consistency ratio (CR) of 0.007. The top-priority strategy was “corrosion prevention and early response,” emphasizing the importance of preventive technologies and rapid response systems. Among the sub-factors, “application of preventive technologies” ranked highest, confirming its effectiveness in enhancing system reliability and maintenance efficiency. The results of this study suggest that the priority implementation of corrosion prevention measures and establishment of a rapid response system are essential to ensure the long-term performance and safety of sprinkler-based fire response systems.
- 30 June 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (3) , 67-75
Open AccessPriority Evaluation of Corrosion Mitigation Strategies for Sprinkler Metallic Pipes in Underground Parking Facilities Based on the Analytic Hierarchy Process (AHP)
Underground parking facilities are prone to metal pipe corrosion owing to their high humidity and enclosed conditions, which can reduce the reliability of fire protection systems. This study identified key strategies to address corrosion in sprinkler piping and applied the Analytic Hierarchy Process (AHP) to evaluate their priorities. Five main strategy categories and 15 subfactors were assessed through expert consultation and a survey of 35 fire safety professionals. The analysis revealed a high consistency ratio (CR) of 0.007. The top-priority strategy was “corrosion prevention and early response,” emphasizing the importance of preventive technologies and rapid response systems. Among the sub-factors, “application of preventive technologies” ranked highest, confirming its effectiveness in enhancing system reliability and maintenance efficiency. The results of this study suggest that the priority implementation of corrosion prevention measures and establishment of a rapid response system are essential to ensure the long-term performance and safety of sprinkler-based fire response systems.
- Open Access
- 28 February 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (1) , 67-75
Corrosion Prevention in Sprinkler Metal Pipes using Silicate-based Corrosion Inhibitors and Electrolyzed-Reduced Water
Buildings exceeding a specified size are mandated to install sprinkler systems in underground parking lots to suppress fires until the fire department arrives. However, the metal pipes used in these sprinkler systems are highly susceptible to corrosion, which can lead to rust formation and associated issues, thereby diminishing the reliability of the fire protection system and resulting in significant economic losses for the building. This study examined the corrosion inhibition mechanism of electrolyzed-reduced water and silicate-based corrosion inhibitors via electrochemical analysis. Additionally, their effects on the protection of metal pipes were assessed. After the formation of a protective film by injecting the inhibitors into fire suppression pipes for 72 h, its corrosion prevention performance was evaluated using scanning electron microscopy (SEM), energy-dispersive spectroscopy (EDS), and electrochemical techniques. Results demonstrated that the protective film effectively inhibited corrosion, reduced the corrosion current density, and significantly enhanced the corrosion resistance of the metal pipes, thereby extending their expected service life.
- 28 February 2025
- Published by Korean Society of Hazard Mitigation in Journal of the Korean Society of Hazard Mitigation
- Vol. 25 (1) , 67-75
Open AccessCorrosion Prevention in Sprinkler Metal Pipes using Silicate-based Corrosion Inhibitors and Electrolyzed-Reduced Water
Buildings exceeding a specified size are mandated to install sprinkler systems in underground parking lots to suppress fires until the fire department arrives. However, the metal pipes used in these sprinkler systems are highly susceptible to corrosion, which can lead to rust formation and associated issues, thereby diminishing the reliability of the fire protection system and resulting in significant economic losses for the building. This study examined the corrosion inhibition mechanism of electrolyzed-reduced water and silicate-based corrosion inhibitors via electrochemical analysis. Additionally, their effects on the protection of metal pipes were assessed. After the formation of a protective film by injecting the inhibitors into fire suppression pipes for 72 h, its corrosion prevention performance was evaluated using scanning electron microscopy (SEM), energy-dispersive spectroscopy (EDS), and electrochemical techniques. Results demonstrated that the protective film effectively inhibited corrosion, reduced the corrosion current density, and significantly enhanced the corrosion resistance of the metal pipes, thereby extending their expected service life.