Jorge Martinez-Garcia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jorge Martinez-Garcia has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Damian Gwerder
Competence Centre for Thermal Energy Storage, Lucerne University of Applied Science and Arts, 6048 Horw, Switzerland
10 shared publications - Philipp Schuetz
Medical University Department, Division of General Internal and Emergency Medicine, Kantonsspital Aarau, Aarau, Switzerland; Medical Faculty of the University of Basel, Basel, Switzerland
8 shared publications - Dario Guarda
Department of Management and Engineering, University of Padova, 36100 Vicenza, Italy
5 shared publications Philipp Schuetz
5 shared publicationsAnastasia Stamatiou
4 shared publicationsDavid Schiffmann
4 shared publications
Latest Publications
- Open Access
- 20 October 2026
- Published by Elsevier in SSRN Electronic Journal
In Situ Imaging of CO2 Capture Dynamics and Multiscale TransportPathways in a MOF Packed Bed
Atmospheric carbon dioxide (CO2) concentrations continue to break historical records. Consequently, developing high-efficiency carbon capture technologies remains imperative to mitigate climate change and support global net-zero goals. Metal-organic frameworks (MOFs) are highly promising materials for carbon capture, yet resolving their mass transfer dynamics under realistic operating conditions remains a significant challenge. This study utilises industrial in-situ X-ray computed tomography (XCT) to non-destructively image CO2 uptake within a packed bed of MOF particles. Using complementary static and time-resolved in-situXCT measurements, we characterise the intra-particle pore networks and monitor localised gas accumulation across a cyclic dosing sequence up to 45 min of cumulative gas exposure. Static characterisation reveals a distinct microstructural anisotropy, where open connectivity increases monotonically toward the apex (reaching 2.73%). Fluid flow modelling shows gas transport is strongly dominated by this pore connectivity, yielding a peak local CO2 permeability of 0.0193 µm2 at the apex. Time-resolved in-situ XCT monitoring demonstrates that variations in local gas concentration are directly detectable as a progressive peak shift within the gray value distributions, culminating in a 3.70% relative increase in X-ray attenuation at full saturation. These results provide direct, localised evidence of dynamic intra-particle gas uptake, establishing time-resolved XCT as a powerful quantitative diagnostic tool for optimising MOF packed beds and validating intra-particle diffusion pathways.
- 20 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessIn Situ Imaging of CO2 Capture Dynamics and Multiscale TransportPathways in a MOF Packed Bed
Atmospheric carbon dioxide (CO2) concentrations continue to break historical records. Consequently, developing high-efficiency carbon capture technologies remains imperative to mitigate climate change and support global net-zero goals. Metal-organic frameworks (MOFs) are highly promising materials for carbon capture, yet resolving their mass transfer dynamics under realistic operating conditions remains a significant challenge. This study utilises industrial in-situ X-ray computed tomography (XCT) to non-destructively image CO2 uptake within a packed bed of MOF particles. Using complementary static and time-resolved in-situXCT measurements, we characterise the intra-particle pore networks and monitor localised gas accumulation across a cyclic dosing sequence up to 45 min of cumulative gas exposure. Static characterisation reveals a distinct microstructural anisotropy, where open connectivity increases monotonically toward the apex (reaching 2.73%). Fluid flow modelling shows gas transport is strongly dominated by this pore connectivity, yielding a peak local CO2 permeability of 0.0193 µm2 at the apex. Time-resolved in-situ XCT monitoring demonstrates that variations in local gas concentration are directly detectable as a progressive peak shift within the gray value distributions, culminating in a 3.70% relative increase in X-ray attenuation at full saturation. These results provide direct, localised evidence of dynamic intra-particle gas uptake, establishing time-resolved XCT as a powerful quantitative diagnostic tool for optimising MOF packed beds and validating intra-particle diffusion pathways.
- 1 July 2026
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 31 (7)
Unveiling CO2 uptake in a metal-organic frameworks (MOFs) based packed bed by X-ray computed tomography
Atmospheric carbon dioxide (CO2) levels reached records in 2024, committing the planet to further warming. Developing novel strategies to capture CO2 is thus crucial to mitigating climate change and achieving net-zero emissions. In this work, X-ray computed tomography (XCT) is used to investigate non-destructively how CO2 is absorbed in a metal organic framework (MOF)-based packed bed reactor. Both static and dynamic in-situ XCT measurements are performed to characterize the MOF’s and packed bed’s pore-structure and tracking the CO2 uptake. It’s shown that change in CO2 concentration is detectable as a shift to higher grey values in the grey value distribution. It was found that pores become less interconnected further inside the particle, becoming less accessible to CO2 gas. This observation suggests a more significant particle surface-level CO2 uptake, here assessed through a developed image processing approach. This research helps to improve the uptake of CO2 from the atmosphere and thereby to reduce the share of greenhouse gases.
- 1 July 2026
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 31 (7)
Unveiling CO2 uptake in a metal-organic frameworks (MOFs) based packed bed by X-ray computed tomography
Atmospheric carbon dioxide (CO2) levels reached records in 2024, committing the planet to further warming. Developing novel strategies to capture CO2 is thus crucial to mitigating climate change and achieving net-zero emissions. In this work, X-ray computed tomography (XCT) is used to investigate non-destructively how CO2 is absorbed in a metal organic framework (MOF)-based packed bed reactor. Both static and dynamic in-situ XCT measurements are performed to characterize the MOF’s and packed bed’s pore-structure and tracking the CO2 uptake. It’s shown that change in CO2 concentration is detectable as a shift to higher grey values in the grey value distribution. It was found that pores become less interconnected further inside the particle, becoming less accessible to CO2 gas. This observation suggests a more significant particle surface-level CO2 uptake, here assessed through a developed image processing approach. This research helps to improve the uptake of CO2 from the atmosphere and thereby to reduce the share of greenhouse gases.
- Open Access
Applications of X-Ray Computed Tomography Technology to Solid–Liquid Phase Change Materials—A Review
Latent heat thermal energy storage (LHTES) based on phase change materials (PCMs) is receiving increasing interest since it offers high energy storage density while enabling the integration of variable renewable energies, hence boosting the transition towards a climate-neutral future. Despite the advantages that PCMs offer in providing a nearly isothermal solid–liquid phase transition, they still face some challenges that limit their deployment in real applications such as low thermal conductivity, phase separation, and supercooling, which affect charging and discharging rates. X-ray computed tomography (XCT) is a non-destructive imaging technique widely used in materials science for both qualitative and quantitative analysis of material microstructures and their evolution. Recent advances in laboratory-XCT instrumentation enabled short acquisition times on the order of tens of seconds which allows the investigation of dynamic processes in situ by time-lapse XCT measurements. These advances open new opportunities for revealing information on the morphology of solid–liquid PCMs. Despite the fact that XCT imaging has significant potential for energy research, its application in the field of PCMs is fairly new. A key enabler of applications of XCT to PCMs is the density difference between solid and liquid PCMs, which was found to be higher than 7% for all investigated PCMs. This enabled solid and liquid phases to be distinguished one from the other and properly quantified over time. The present work reviews the principles of laboratory-based XCT and the recent applications of XCT technology in the characterisation of PCMs, with emphasis on the study of the solid–liquid phase transition and validation of numerical PCM models by addressing the potentialities and challenges of XCT in PCM research.
Open AccessApplications of X-Ray Computed Tomography Technology to Solid–Liquid Phase Change Materials—A Review
Latent heat thermal energy storage (LHTES) based on phase change materials (PCMs) is receiving increasing interest since it offers high energy storage density while enabling the integration of variable renewable energies, hence boosting the transition towards a climate-neutral future. Despite the advantages that PCMs offer in providing a nearly isothermal solid–liquid phase transition, they still face some challenges that limit their deployment in real applications such as low thermal conductivity, phase separation, and supercooling, which affect charging and discharging rates. X-ray computed tomography (XCT) is a non-destructive imaging technique widely used in materials science for both qualitative and quantitative analysis of material microstructures and their evolution. Recent advances in laboratory-XCT instrumentation enabled short acquisition times on the order of tens of seconds which allows the investigation of dynamic processes in situ by time-lapse XCT measurements. These advances open new opportunities for revealing information on the morphology of solid–liquid PCMs. Despite the fact that XCT imaging has significant potential for energy research, its application in the field of PCMs is fairly new. A key enabler of applications of XCT to PCMs is the density difference between solid and liquid PCMs, which was found to be higher than 7% for all investigated PCMs. This enabled solid and liquid phases to be distinguished one from the other and properly quantified over time. The present work reviews the principles of laboratory-based XCT and the recent applications of XCT technology in the characterisation of PCMs, with emphasis on the study of the solid–liquid phase transition and validation of numerical PCM models by addressing the potentialities and challenges of XCT in PCM research.
- Open Access
- 3 July 2025
- Published by MDPI AG in Preprints.org
Applications of Computed Tomography (CT) Technology to Solid-Liquid Phase Change Materials—A Review
Latent Heat Thermal Energy Storage (LHTES) based on phase change materials (PCM) is receiving increasing interest, since it offers high energy storage density while enabling the integration of variable renewable energies, hence boosting the transition towards a climate-neutral future. Despite the advantages that PCMs offer in providing a nearly isothermal solid–liquid phase transition, they still face some challenges that limit their deployment in real applications such as, low thermal conductivity, phase separation and supercooling, which affect charging and discharging rates. X-ray computed tomography (XCT) is a non-destructive imaging technique widely used in materials science for both qualitative and quantitative analysis of material microstructures and their evolution. Recent advances in laboratory-XCT instrumentation enabled short acquisition times on the order of tens of seconds which enable the investigation of dynamic processes in-situ by time-lapse XCT measurements. These advances open new opportunities for revealing information on the solid-liquid PCMs. Despite XCT imaging has significant potential for energy research, its application in the field of PCMs is fairly new. The present work reviews the principles of laboratory-based XCT and the recent applications of XCT technology in the characterisation of PCMs, with emphasis on the study of the solid-liquid phase transition and validation of numerical PCM models.
- 3 July 2025
- Published by MDPI AG in Preprints.org
Open AccessApplications of Computed Tomography (CT) Technology to Solid-Liquid Phase Change Materials—A Review
Latent Heat Thermal Energy Storage (LHTES) based on phase change materials (PCM) is receiving increasing interest, since it offers high energy storage density while enabling the integration of variable renewable energies, hence boosting the transition towards a climate-neutral future. Despite the advantages that PCMs offer in providing a nearly isothermal solid–liquid phase transition, they still face some challenges that limit their deployment in real applications such as, low thermal conductivity, phase separation and supercooling, which affect charging and discharging rates. X-ray computed tomography (XCT) is a non-destructive imaging technique widely used in materials science for both qualitative and quantitative analysis of material microstructures and their evolution. Recent advances in laboratory-XCT instrumentation enabled short acquisition times on the order of tens of seconds which enable the investigation of dynamic processes in-situ by time-lapse XCT measurements. These advances open new opportunities for revealing information on the solid-liquid PCMs. Despite XCT imaging has significant potential for energy research, its application in the field of PCMs is fairly new. The present work reviews the principles of laboratory-based XCT and the recent applications of XCT technology in the characterisation of PCMs, with emphasis on the study of the solid-liquid phase transition and validation of numerical PCM models.
- Open Access
- 1 February 2025
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 30 (2)
CO2 adsorption on microporous metal–organic frameworks unravelled by high-resolution X-ray computed tomography
The continuous increase in atmospheric carbon dioxide (CO2) concentration has triggered global warming and climate change. Strong policies and novel, cost-effective CO2 control methods have been developed to mitigate these issues over the last years. Metal-organic frameworks (MOFs) have emerged as one of the most rapidly advancing areas of research in chemistry, driven by advancements in synthesis, structure determination, interdisciplinary research, and broadening applications. MOFs porous materials demonstrate significant CO2 capture and conversion capabilities due to their tunable physical and chemical properties. Characterization of the MOF’s pore structure and its effect on CO2 adsorption are crucial to understanding the CO2 storage mechanisms and, thus, for optimal MOF design. This study uses X-ray computed tomography (XCT) to investigate non-destructively how CO2 is adsorbed on MOF’s particles. This contribution presents the characterization of the micron-scale pore structure of a single MOF particle. The collected imaging data is used to calculate the effective permeability along the MOF’s particle through numerical simulations. Findings reveal that the pore connectivity decreases with the particle penetration length, thus reducing the available surface area for adsorption. Additionally, the permeability near the particle surface is found to be 6.39 times higher than inside the particle. Potential CO2 location sites at the particle surfaces were also identified and visualized.
- 1 February 2025
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 30 (2)
Open AccessCO2 adsorption on microporous metal–organic frameworks unravelled by high-resolution X-ray computed tomography
The continuous increase in atmospheric carbon dioxide (CO2) concentration has triggered global warming and climate change. Strong policies and novel, cost-effective CO2 control methods have been developed to mitigate these issues over the last years. Metal-organic frameworks (MOFs) have emerged as one of the most rapidly advancing areas of research in chemistry, driven by advancements in synthesis, structure determination, interdisciplinary research, and broadening applications. MOFs porous materials demonstrate significant CO2 capture and conversion capabilities due to their tunable physical and chemical properties. Characterization of the MOF’s pore structure and its effect on CO2 adsorption are crucial to understanding the CO2 storage mechanisms and, thus, for optimal MOF design. This study uses X-ray computed tomography (XCT) to investigate non-destructively how CO2 is adsorbed on MOF’s particles. This contribution presents the characterization of the micron-scale pore structure of a single MOF particle. The collected imaging data is used to calculate the effective permeability along the MOF’s particle through numerical simulations. Findings reveal that the pore connectivity decreases with the particle penetration length, thus reducing the available surface area for adsorption. Additionally, the permeability near the particle surface is found to be 6.39 times higher than inside the particle. Potential CO2 location sites at the particle surfaces were also identified and visualized.
- Open Access
- 1 March 2024
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 29 (3)
Energy-selective X-ray CT imaging with an EIGER2 hybrid photon counting detector in a Diondo d2 XCT system
Hybrid photon counting (HPC) detector having high spatial resolution and photon energy discrimination capabilities can remarkably improve the quality of X-ray computed tomography (XCT) measurements. In this contribution, we report on the integration of an....
- 1 March 2024
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 29 (3)
Open AccessEnergy-selective X-ray CT imaging with an EIGER2 hybrid photon counting detector in a Diondo d2 XCT system
Hybrid photon counting (HPC) detector having high spatial resolution and photon energy discrimination capabilities can remarkably improve the quality of X-ray computed tomography (XCT) measurements. In this contribution, we report on the integration of an....
- Open Access
- 2 June 2023
- Published by Taylor & Francis in Journal of the American Institute for Conservation
- Vol. 63 (1) , 14-27
Non-destructive Dendrochronology: The Effect of Conservation Agents on Tree-ring Measurements in Archaeological Oak with Micro-computed Tomography
- 2 June 2023
- Published by Taylor & Francis in Journal of the American Institute for Conservation
- Vol. 63 (1) , 14-27
Open AccessNon-destructive Dendrochronology: The Effect of Conservation Agents on Tree-ring Measurements in Archaeological Oak with Micro-computed Tomography
- Open Access
- 15 March 2023
- Published by Wiley in Chemie Ingenieur Technik
- Vol. 95 (5) , 792-796
Flow Field Simulation and Measurement in Packed Beds Based on 4D‐X‐Ray Computed Tomography
- 15 March 2023
- Published by Wiley in Chemie Ingenieur Technik
- Vol. 95 (5) , 792-796
Open AccessFlow Field Simulation and Measurement in Packed Beds Based on 4D‐X‐Ray Computed Tomography