Yicheng Liao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yicheng Liao has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Xu Liu
Huazhong University of Science and Technology
6 shared publications - Bin Qin
State Key Laboratory of Advanced Electromagnetic Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430070, Hubei, P. R. China
5 shared publications Qushan Chen
3 shared publications- Bin Qin
State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, Hubei, China
2 shared publications - Qushan Chen
Huazhong University of Science and Technology
2 shared publications Runxiao Zhao
2 shared publications
Latest Publications
- 4 September 2026
- Published by Elsevier in International Journal of Mass Spectrometry
- Vol. 529-530
A trajectory-based transfer-matrix coefficient extraction method for efficient double-focusing mass spectrometers design
- 4 September 2026
- Published by Elsevier in International Journal of Mass Spectrometry
- Vol. 529-530
A trajectory-based transfer-matrix coefficient extraction method for efficient double-focusing mass spectrometers design
- 7 January 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics A
- Vol. 41 (04)
Miniaturization design study of a dipole magnet applied to proton therapy beamline
The miniaturization of magnets is crucial for reducing both the physical footprint and the construction cost of a proton therapy facility. The configuration of dipole magnets significantly influences the design of the compact gantry. However, current research demonstrates a degree of subjectivity in achieving an optimal balance between magnet compactness and saturation levels. This study introduces a novel design principle aimed at miniaturizing the yoke of dipole magnets. To be specific, two metrics (i.e. magnet efficiency and magnetization uniformity) are adopted to develop an optimized design that achieves significant weight reduction while maintaining essential magnetic performance characteristics. For the 57-degree dipole magnet discussed in this paper, finite element simulations demonstrate that the optimized design achieves a weight reduction of 39.6% for the yoke (from 5.38 to 3.24 tons) while maintaining transverse and integrated field homogeneity within the stringent [ ] tolerance threshold, and exhibits satisfactory excitation linearity. The design of this study can provide insight for the subsequent construction of a compact gantry.
- 7 January 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics A
- Vol. 41 (04)
Miniaturization design study of a dipole magnet applied to proton therapy beamline
The miniaturization of magnets is crucial for reducing both the physical footprint and the construction cost of a proton therapy facility. The configuration of dipole magnets significantly influences the design of the compact gantry. However, current research demonstrates a degree of subjectivity in achieving an optimal balance between magnet compactness and saturation levels. This study introduces a novel design principle aimed at miniaturizing the yoke of dipole magnets. To be specific, two metrics (i.e. magnet efficiency and magnetization uniformity) are adopted to develop an optimized design that achieves significant weight reduction while maintaining essential magnetic performance characteristics. For the 57-degree dipole magnet discussed in this paper, finite element simulations demonstrate that the optimized design achieves a weight reduction of 39.6% for the yoke (from 5.38 to 3.24 tons) while maintaining transverse and integrated field homogeneity within the stringent [ ] tolerance threshold, and exhibits satisfactory excitation linearity. The design of this study can provide insight for the subsequent construction of a compact gantry.
- 30 December 2024
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics A
- Vol. 40 (01)
A data-efficient surrogate modeling method for a cyclotron-based proton therapy beamline based on active learning
High-fidelity beamline models typically involve particle-tracking and particle–matter interaction, which are intensive computationally demanding and time-consuming. This has led researchers to adopt data-driven surrogate models as an alternative to complex physics simulations. Training a data-driven model requires many labeled data, prompting researchers to simulate diverse beamline settings and obtain corresponding labels. However, the required dataset grows increasingly large as the number of adjustable parameters increases. Therefore, this study proposes a data-efficient surrogate modeling method that employs a student–teacher framework combined with active learning (AL) query strategies to minimize labeled samples while ensuring model accuracy. The proposed method is evaluated on the energy selection system (ESS) design of the Huazhong University of Science and Technology proton therapy facility (HUST-PTF). The results show that: (i) Training the surrogate model using 684 labeled samples selected via query strategy achieves a relative error below 5% for 90% of the samples in the test set. (ii) Compared to the beamline model built by Beam Delivery Simulation (BDSIM), the computational efficiency of the surrogate model is enhanced by a factor of [ ].
- 30 December 2024
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics A
- Vol. 40 (01)
A data-efficient surrogate modeling method for a cyclotron-based proton therapy beamline based on active learning
High-fidelity beamline models typically involve particle-tracking and particle–matter interaction, which are intensive computationally demanding and time-consuming. This has led researchers to adopt data-driven surrogate models as an alternative to complex physics simulations. Training a data-driven model requires many labeled data, prompting researchers to simulate diverse beamline settings and obtain corresponding labels. However, the required dataset grows increasingly large as the number of adjustable parameters increases. Therefore, this study proposes a data-efficient surrogate modeling method that employs a student–teacher framework combined with active learning (AL) query strategies to minimize labeled samples while ensuring model accuracy. The proposed method is evaluated on the energy selection system (ESS) design of the Huazhong University of Science and Technology proton therapy facility (HUST-PTF). The results show that: (i) Training the surrogate model using 684 labeled samples selected via query strategy achieves a relative error below 5% for 90% of the samples in the test set. (ii) Compared to the beamline model built by Beam Delivery Simulation (BDSIM), the computational efficiency of the surrogate model is enhanced by a factor of [ ].
- 21 September 2024
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 35 (10) , 1-11
Design of a large momentum acceptance proton therapy gantry utilizing AG-CCT magnets
- 21 September 2024
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 35 (10) , 1-11
Design of a large momentum acceptance proton therapy gantry utilizing AG-CCT magnets
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
A Framework for the Magnetic Design of Large Bore, Curved AG-CCT Magnets for Proton Therapy Facilities
The canted-cosine-theta (CCT) magnet is a promising candidate for shrinking the volume of the gantry for radiotherapy facilities. The magnets are often demanded to have large bores and small bending radii in the gantry design, which would lead to complex harmonic coupling and non-negligible fringe-field effects. To address these issues, a design framework is proposed in this contribution. The winding coefficients of the CCT coils are firstly determined by an improved backcasting algorithm to cancel out the harmonics. A toroidal shielding iron is mounted outside of the coil afterward, which can not only lower the stray field but also significantly eliminate the overshooting of the fringe field. The excitation efficiency of the magnet is enhanced by the shield without introducing any high-order harmonics. This framework is validated on an AG-CCT magnet being developed for our superconducting proton therapy gantry. The field derivatives and particle tracking results meet our optical design value well.
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
A Framework for the Magnetic Design of Large Bore, Curved AG-CCT Magnets for Proton Therapy Facilities
The canted-cosine-theta (CCT) magnet is a promising candidate for shrinking the volume of the gantry for radiotherapy facilities. The magnets are often demanded to have large bores and small bending radii in the gantry design, which would lead to complex harmonic coupling and non-negligible fringe-field effects. To address these issues, a design framework is proposed in this contribution. The winding coefficients of the CCT coils are firstly determined by an improved backcasting algorithm to cancel out the harmonics. A toroidal shielding iron is mounted outside of the coil afterward, which can not only lower the stray field but also significantly eliminate the overshooting of the fringe field. The excitation efficiency of the magnet is enhanced by the shield without introducing any high-order harmonics. This framework is validated on an AG-CCT magnet being developed for our superconducting proton therapy gantry. The field derivatives and particle tracking results meet our optical design value well.
- 6 November 2015
- Published by Oxford University Press (OUP) in Diseases of the Esophagus
- Vol. 29 (8) , 1043-1047
Novel methylene blue staining technique for localizing small esophageal leiomyomas during thoracoscopic enucleation
The treatment of choice for leiomyoma, the most common benign esophageal tumor, is thoracoscopic enucleation. One of the most difficult aspects of thoracoscopic enucleation is the precise localization of small tumors (≤1.5 cm) and tumors without external protrusion. No simple, feasible solutions to this problem are available. We developed a novel methylene blue staining technique to localize small esophageal leiomyomas and evaluated the feasibility of our technique. Between January 2013 and July 2014, eight patients with small esophageal leiomyomas (≤1.5 cm) underwent thoracoscopic enucleation in Tongji Hospital. Preoperative endoscopic ultrasonography was performed in all patients. The leiomyomas were located in the middle (n = 5) and lower (n = 3) thirds of the esophagus. We preoperatively injected 0.5–1.0 mL methylene blue in the submucosa adjacent to the tumors under standard gastroscope guidance. The entire staining process took about 10 minutes. Staining was successful in all patients. The unstained tumor was exposed after the blue-stained mediastinal pleura, and overlying muscle were incised longitudinally. All procedures were successfully completed without conversion to open surgery. No abnormalities were detected in the esophageal mucosa. The median operating time was 60 minutes (range, 40–90 minutes). Postoperative histopathology confirmed leiomyoma in all patients. The median postoperative hospital stay was 6 days (range, 5–7 days). No major complications, such as esophageal leakage or esophageal diverticulum, occurred. Endoscopic methylene blue staining is safe and feasible for localizing small esophageal leiomyomas during thoracoscopic enucleation. This method will enable precise and easy enucleation.
- 6 November 2015
- Published by Oxford University Press (OUP) in Diseases of the Esophagus
- Vol. 29 (8) , 1043-1047
Novel methylene blue staining technique for localizing small esophageal leiomyomas during thoracoscopic enucleation
The treatment of choice for leiomyoma, the most common benign esophageal tumor, is thoracoscopic enucleation. One of the most difficult aspects of thoracoscopic enucleation is the precise localization of small tumors (≤1.5 cm) and tumors without external protrusion. No simple, feasible solutions to this problem are available. We developed a novel methylene blue staining technique to localize small esophageal leiomyomas and evaluated the feasibility of our technique. Between January 2013 and July 2014, eight patients with small esophageal leiomyomas (≤1.5 cm) underwent thoracoscopic enucleation in Tongji Hospital. Preoperative endoscopic ultrasonography was performed in all patients. The leiomyomas were located in the middle (n = 5) and lower (n = 3) thirds of the esophagus. We preoperatively injected 0.5–1.0 mL methylene blue in the submucosa adjacent to the tumors under standard gastroscope guidance. The entire staining process took about 10 minutes. Staining was successful in all patients. The unstained tumor was exposed after the blue-stained mediastinal pleura, and overlying muscle were incised longitudinally. All procedures were successfully completed without conversion to open surgery. No abnormalities were detected in the esophageal mucosa. The median operating time was 60 minutes (range, 40–90 minutes). Postoperative histopathology confirmed leiomyoma in all patients. The median postoperative hospital stay was 6 days (range, 5–7 days). No major complications, such as esophageal leakage or esophageal diverticulum, occurred. Endoscopic methylene blue staining is safe and feasible for localizing small esophageal leiomyomas during thoracoscopic enucleation. This method will enable precise and easy enucleation.