Guangzhen Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Guangzhen Wang has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Anna Min Du
The Business School, Edinburgh Napier University Edinburgh UK
2 shared publications - Shufeng Ye
State Key Laboratory of Mesoscience and Engineering, Institute of Process Engineering, Chinese Academy of Sciences, Beijing 100190, China
2 shared publications - Zhongyang Guo
Key Laboratory of Geographic Information Science, Ministry of Education, East China Normal University, Shanghai 200241, China
2 shared publications - Beilei Yang
School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, China
1 shared publication - Bo Zhang
School of Information Science and Technology, Fudan University, Shanghai 200438, China
1 shared publication Chao Wei
Key Laboratory of Geographic Information Science, Ministry of Education, East China Normal University, Shanghai, China
1 shared publication
Latest Publications
- 11 May 2023
- Published by Springer Nature
- p. 479-486
Research on Defect Simulation and Diagnosis Method of On-Load Tap Changer
- 11 May 2023
- Published by Springer Nature
- p. 479-486
Research on Defect Simulation and Diagnosis Method of On-Load Tap Changer
- 15 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Research on Surface Discharge Direction Algorithm of Converter Valve Based on Ultraviolet Array Sensor
To monitor the surface discharge with high sensitivity in the converter valve, the ultraviolet array sensor is designed. The propagation mode of ultraviolet signal of surface discharge of converter valve is analyzed by ray tracing method, and the direction algorithm of surface discharge based on phased array technology is proposed, and the noise space and signal subspace of 4-channel ultraviolet signal are extracted by rotating signal subspace algorithm. The positioning results of multiple surface discharges are simulated and analyzed, and the direction error is less than 1 degree, which provides a new algorithm for non-intrusive condition monitoring of converter valve.
- 15 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Research on Surface Discharge Direction Algorithm of Converter Valve Based on Ultraviolet Array Sensor
To monitor the surface discharge with high sensitivity in the converter valve, the ultraviolet array sensor is designed. The propagation mode of ultraviolet signal of surface discharge of converter valve is analyzed by ray tracing method, and the direction algorithm of surface discharge based on phased array technology is proposed, and the noise space and signal subspace of 4-channel ultraviolet signal are extracted by rotating signal subspace algorithm. The positioning results of multiple surface discharges are simulated and analyzed, and the direction error is less than 1 degree, which provides a new algorithm for non-intrusive condition monitoring of converter valve.
- 5 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-8
Highly Sensitive Optical Fiber Photoacoustic Sensor for In Situ Detection of Dissolved Gas in Oil
A highly sensitive optical fiber photoacoustic (PA) sensor was proposed and demonstrated for in situ detection of dissolved gas in oil. Two optical fibers were used for the transmission of pump light and probe light, respectively. The miniature detection module integrated by optical fiber sensor and oil–gas separation membrane made it passive and anti-electromagnetic interference. The dissolved gas in oil passed through the organic membrane into the micro-chamber of the PA sensor. The PA signal generated by the gas absorption of laser energy was detected by a Fabry–Perot interferometric cantilever. To reduce the equilibrium time of oil–gas separation and improve the PA response, structural parameters of the sensor were optimized. The experimental results showed that the temperature had an influence on the response time and PA response. The response time was ~1.8 h at 50 °C. To realize temperature compensation, the temperature was measured simultaneously by averaging the measured Fabry–Perot cavity length. In addition, the detection limit of dissolved acetylene (C 2 H 2 ) gas reached $0.5~\mu \text{L}$ /L. Since oil pumping was not required and the oil did not contact with the ambient air, the oil was not polluted and consumed to achieve in situ measurement.
- 5 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-8
Highly Sensitive Optical Fiber Photoacoustic Sensor for In Situ Detection of Dissolved Gas in Oil
A highly sensitive optical fiber photoacoustic (PA) sensor was proposed and demonstrated for in situ detection of dissolved gas in oil. Two optical fibers were used for the transmission of pump light and probe light, respectively. The miniature detection module integrated by optical fiber sensor and oil–gas separation membrane made it passive and anti-electromagnetic interference. The dissolved gas in oil passed through the organic membrane into the micro-chamber of the PA sensor. The PA signal generated by the gas absorption of laser energy was detected by a Fabry–Perot interferometric cantilever. To reduce the equilibrium time of oil–gas separation and improve the PA response, structural parameters of the sensor were optimized. The experimental results showed that the temperature had an influence on the response time and PA response. The response time was ~1.8 h at 50 °C. To realize temperature compensation, the temperature was measured simultaneously by averaging the measured Fabry–Perot cavity length. In addition, the detection limit of dissolved acetylene (C 2 H 2 ) gas reached $0.5~\mu \text{L}$ /L. Since oil pumping was not required and the oil did not contact with the ambient air, the oil was not polluted and consumed to achieve in situ measurement.
- 1 May 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4, 897-902
The main functional zone —A case study of Yangtze River Delta coastal area
The study area of this paper is eight cities' coastal zone in Yangtze River Delta. We took resources and environment carrying capacity, exiting development density and future development potential as spatial dimensions of three-dimensional cube, and got 27 units. According to results of second level indicators, we found the cube type of each coastal area and their main functional zone type. The results show: the coastal areas in Hangzhou, Zhoushan and Shanghai belong to stress developing area, Suzhou and Ningbo are optimization developing areas; however, the coastal area in Nantong, Jiaxing and Shaoxing are limited developing ones.
- 1 May 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4, 897-902
The main functional zone —A case study of Yangtze River Delta coastal area
The study area of this paper is eight cities' coastal zone in Yangtze River Delta. We took resources and environment carrying capacity, exiting development density and future development potential as spatial dimensions of three-dimensional cube, and got 27 units. According to results of second level indicators, we found the cube type of each coastal area and their main functional zone type. The results show: the coastal areas in Hangzhou, Zhoushan and Shanghai belong to stress developing area, Suzhou and Ningbo are optimization developing areas; however, the coastal area in Nantong, Jiaxing and Shaoxing are limited developing ones.
- 1 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 108-111
Assessing the Ecological Assets in Coastal Zone Using Remote Sensing Data: A Case Study of Pudong New Area, Shanghai
This paper presents a new system of indicators for ecological assets assessment and a method for evaluating ecological total assets. With Remote Sensing images of Pudong New Area in 1998 and 2005, we got down to calculating vegetation coverage, Vegetation Net Primary Productivity (NPP) and adjustment factor. The distribution pattern of ecological assets of Pudong New Area in 1998 and 2005 as well as the ecological environment degradation between them were analyzed and mapped using DEM, meteorological and mentioned ancillary data. The whole area was finally divided into five: fast-growing area, moderate growth area, basically maintained area, moderately degraded area and severely degraded area, of which the basically maintained areas account for a large proportion, however, there are a majority of degraded areas, and the growing areas don't reach to 10%. Which reveal the ecological environment in Pudong New Area actually and tell us to spare no efforts to making friends with our nature.
- 1 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 108-111
Assessing the Ecological Assets in Coastal Zone Using Remote Sensing Data: A Case Study of Pudong New Area, Shanghai
This paper presents a new system of indicators for ecological assets assessment and a method for evaluating ecological total assets. With Remote Sensing images of Pudong New Area in 1998 and 2005, we got down to calculating vegetation coverage, Vegetation Net Primary Productivity (NPP) and adjustment factor. The distribution pattern of ecological assets of Pudong New Area in 1998 and 2005 as well as the ecological environment degradation between them were analyzed and mapped using DEM, meteorological and mentioned ancillary data. The whole area was finally divided into five: fast-growing area, moderate growth area, basically maintained area, moderately degraded area and severely degraded area, of which the basically maintained areas account for a large proportion, however, there are a majority of degraded areas, and the growing areas don't reach to 10%. Which reveal the ecological environment in Pudong New Area actually and tell us to spare no efforts to making friends with our nature.
- 1 January 2003
- Published by Chinese Journal of Mechanical Engineering in Chinese Journal of Mechanical Engineering
- Vol. 39 (02) , 79
THERMAL EXPANSION TYPE MICROACTUATOR ACTUATED BY INDUCTION HEATING
- 1 January 2003
- Published by Chinese Journal of Mechanical Engineering in Chinese Journal of Mechanical Engineering
- Vol. 39 (02) , 79
THERMAL EXPANSION TYPE MICROACTUATOR ACTUATED BY INDUCTION HEATING