Hui Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hui Wang has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Fan Zhong
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
4 shared publications Qunzhan Li
4 shared publicationsShaofeng Xie
3 shared publications- Shaofeng Xie
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
3 shared publications - Wei Liu
School of Electrical Engineering, Southwest Jiaotong University, Chengdu 611756, China
3 shared publications Fan Zhong
2 shared publications
Latest Publications
- Open Access
- 3 September 2026
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 17 (9) , 470
Chance-Constrained and CVaR Optimal Dispatch for Co-Phase Traction Power Supply System with PV and HESS
Co-phase traction power supply system (CTPSS) integrated with photovoltaic (PV) and hybrid energy storage system (HESS) can enhance power supply capacity while facilitating the on-site consumption of renewable energy. This integration provides a pathway toward green development and the achievement of the “carbon peaking and carbon neutrality” goal. However, the stochastic nature of PV poses challenges to safe and economical operation of the system. Existing energy management methods remain limited in simultaneously balancing operational economy and extreme risks caused by PV uncertainty, making it difficult to achieve an effective trade-off between operating cost and constraint violation risk. To address this issue, a risk-sensitive optimal scheduling framework integrating probabilistic PV forecasting, correlated scenario generation, and risk-aware optimization is developed. First, a PV probabilistic prediction model based on parallel TCN-BiLSTM-Attention is proposed, which extracts multiscale local features and long-range temporal features from PV for accurate uncertainty quantification. Second, a t-Copula PV scenario generation method driven by weather classification and temporal correlation is proposed. On this basis, a day-ahead optimal scheduling strategy integrating chance constraints programming (CCP) and conditional value at risk (CVaR) is established to simultaneously control constraint violation risk and extreme economic risk. The proposed prediction model can accurately quantify uncertainty, achieving an R2 value of 0.9979. When the allowable power supply loss probability is 0.5%, the proposed scheme’s operating cost is reduced by 1.36% compared with the baseline scheme. The results demonstrate that the proposed framework can effectively coordinate operating economy and extreme-risk control, thereby improving the risk-sensitive operational performance of CTPSS with PV and HESS. The proposed strategy balances economy and extreme risk, providing a reference for safe, low-carbon and economical operation of CTPSS with PV and HESS.
- 3 September 2026
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 17 (9) , 470
Open AccessChance-Constrained and CVaR Optimal Dispatch for Co-Phase Traction Power Supply System with PV and HESS
Co-phase traction power supply system (CTPSS) integrated with photovoltaic (PV) and hybrid energy storage system (HESS) can enhance power supply capacity while facilitating the on-site consumption of renewable energy. This integration provides a pathway toward green development and the achievement of the “carbon peaking and carbon neutrality” goal. However, the stochastic nature of PV poses challenges to safe and economical operation of the system. Existing energy management methods remain limited in simultaneously balancing operational economy and extreme risks caused by PV uncertainty, making it difficult to achieve an effective trade-off between operating cost and constraint violation risk. To address this issue, a risk-sensitive optimal scheduling framework integrating probabilistic PV forecasting, correlated scenario generation, and risk-aware optimization is developed. First, a PV probabilistic prediction model based on parallel TCN-BiLSTM-Attention is proposed, which extracts multiscale local features and long-range temporal features from PV for accurate uncertainty quantification. Second, a t-Copula PV scenario generation method driven by weather classification and temporal correlation is proposed. On this basis, a day-ahead optimal scheduling strategy integrating chance constraints programming (CCP) and conditional value at risk (CVaR) is established to simultaneously control constraint violation risk and extreme economic risk. The proposed prediction model can accurately quantify uncertainty, achieving an R2 value of 0.9979. When the allowable power supply loss probability is 0.5%, the proposed scheme’s operating cost is reduced by 1.36% compared with the baseline scheme. The results demonstrate that the proposed framework can effectively coordinate operating economy and extreme-risk control, thereby improving the risk-sensitive operational performance of CTPSS with PV and HESS. The proposed strategy balances economy and extreme risk, providing a reference for safe, low-carbon and economical operation of CTPSS with PV and HESS.
- Open Access
- 20 November 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 173
Unified modeling and operation strategy for long-distance co-phase cable traction power supply system with novel compensation scheme
- 20 November 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 173
Open AccessUnified modeling and operation strategy for long-distance co-phase cable traction power supply system with novel compensation scheme
- 24 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (4) , 1983-1996
Wide-Band Oscillation Analysis of Railway Power Conditioner-Network-Train Coupling Power System Considering Energy Flow Modes
Railway power conditioner (RPC) is one of the most effective devices in electrified railways for the compensation of negative sequence, reactive power and the utilization of regenerative braking energy. However, the access of RPC will make the railway power supply system exhibit different energy flow modes, which will render the existing principles about wide-band oscillation characteristics opaque (low-frequency oscillation and high-frequency resonance), and increase the difficulty of analysis. The objective of this paper is to present a comprehensive analysis of the wide-band oscillation issue in the RPC-network-train coupling system. Initially, based on the dq decomposition method and mirror-frequency method, a unified impedance model for the system is established considering diverse energy flow modes. Subsequently, the wide-band oscillation distribution is obtained based on the modal decomposition method, thereby revealing the coupling mechanism between the RPC and the existing railway system. The security domain is delineated by further locating the key components affecting the wide-band oscillation based on the sensitivity of the parameters to the frequency and amplitude of the oscillation. Finally, the correctness of the analysis result is verified on the simulation platform and StarSim hardware-in-the-loop experimental platform.
- 24 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (4) , 1983-1996
Wide-Band Oscillation Analysis of Railway Power Conditioner-Network-Train Coupling Power System Considering Energy Flow Modes
Railway power conditioner (RPC) is one of the most effective devices in electrified railways for the compensation of negative sequence, reactive power and the utilization of regenerative braking energy. However, the access of RPC will make the railway power supply system exhibit different energy flow modes, which will render the existing principles about wide-band oscillation characteristics opaque (low-frequency oscillation and high-frequency resonance), and increase the difficulty of analysis. The objective of this paper is to present a comprehensive analysis of the wide-band oscillation issue in the RPC-network-train coupling system. Initially, based on the dq decomposition method and mirror-frequency method, a unified impedance model for the system is established considering diverse energy flow modes. Subsequently, the wide-band oscillation distribution is obtained based on the modal decomposition method, thereby revealing the coupling mechanism between the RPC and the existing railway system. The security domain is delineated by further locating the key components affecting the wide-band oscillation based on the sensitivity of the parameters to the frequency and amplitude of the oscillation. Finally, the correctness of the analysis result is verified on the simulation platform and StarSim hardware-in-the-loop experimental platform.
- 11 March 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 245
Modeling of two-stage continuous co-phase traction power supply system with different compensation schemes
- 11 March 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 245
Modeling of two-stage continuous co-phase traction power supply system with different compensation schemes
- Open Access
- 22 August 2024
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 161
Harmonic resonance evaluation and suppression of railway power conditioner-network-train coupling system
- 22 August 2024
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 161
Open AccessHarmonic resonance evaluation and suppression of railway power conditioner-network-train coupling system
- Open Access
- 11 May 2022
- Published by Emerald Publishing in Railway Sciences
- Vol. 1 (1) , 114-130
Scheme of long distance power supply for electrified railway traction network based on traction cable
Purpose: The traction cable is paralleled with the existing traction network of electrified railway through transverse connecting line to form the scheme of long distance power supply for the traction network. This paper aims to study the scheme composition and power supply distance (PSD) of the scheme.Design/methodology/approach: Based on the structure of parallel traction network (referred to as “cable traction network (CTN)”), the power supply modes (PSMs) are divided into cable + direct PSM and cable + autotransformer (AT) PSM (including Japanese mode, French mode and new mode). Taking cable + Japanese AT PSM as an example, the scheme of long distance power supply for CTN under the PSMs of co-phase and out-of-phase power supply are designed. On the basis of establishing the equivalent circuit model and the chain circuit model of CTN, taking the train working voltage as the constraint condition, and based on the power flow calculation of multiple train loads, the calculation formula and process for determining the PSD of CTN are given. The impedance and PSD of CTN under the cable + AT PSM are simulated and analyzed, and a certain line is taken as an example to compare the scheme design.Findings: Results show that the equivalent impedance of CTN under the cable + AT PSM is smaller, and the PSD is about 2.5 times of that under the AT PSM, which can effectively increase the PSD and the flexibility of external power supply location.Originality/value: The research content can effectively improve the PSD of traction power supply system and has important reference value for the engineering application of the scheme.
- 11 May 2022
- Published by Emerald Publishing in Railway Sciences
- Vol. 1 (1) , 114-130
Open AccessScheme of long distance power supply for electrified railway traction network based on traction cable
Purpose: The traction cable is paralleled with the existing traction network of electrified railway through transverse connecting line to form the scheme of long distance power supply for the traction network. This paper aims to study the scheme composition and power supply distance (PSD) of the scheme.Design/methodology/approach: Based on the structure of parallel traction network (referred to as “cable traction network (CTN)”), the power supply modes (PSMs) are divided into cable + direct PSM and cable + autotransformer (AT) PSM (including Japanese mode, French mode and new mode). Taking cable + Japanese AT PSM as an example, the scheme of long distance power supply for CTN under the PSMs of co-phase and out-of-phase power supply are designed. On the basis of establishing the equivalent circuit model and the chain circuit model of CTN, taking the train working voltage as the constraint condition, and based on the power flow calculation of multiple train loads, the calculation formula and process for determining the PSD of CTN are given. The impedance and PSD of CTN under the cable + AT PSM are simulated and analyzed, and a certain line is taken as an example to compare the scheme design.Findings: Results show that the equivalent impedance of CTN under the cable + AT PSM is smaller, and the PSD is about 2.5 times of that under the AT PSM, which can effectively increase the PSD and the flexibility of external power supply location.Originality/value: The research content can effectively improve the PSD of traction power supply system and has important reference value for the engineering application of the scheme.
- 12 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 70 (10) , 9898-9909
Modified AC/DC Unified Power Flow and Energy-Saving Evaluation for Urban Rail Power Supply System With Energy Feedback Systems
Energy feedback systems (EFSs) have been widely applied in urban rail transit, and a power flow algorithm and energy-saving evaluation of urban rail power supply systems with EFSs are studied in this paper. First, trains, the reflux system, and traction substations with EFSs are modeled, and the multimode transitions are analyzed, including the maximum power state of the EFS. Then, a modified AC/DC unified power flow algorithm for the DC power supply system, which simplified the DC reflux system is proposed, and a field case study based on a multiple train scenario is presented to validate the algorithm. Furthermore, system-level energy-saving evaluation indexes are applied according to system power flow analysis. When the headway time decreases, the proposed indexes decrease in general mainly as there is more regenerative braking energy absorbed by adjacent trains. The higher the load rates of the step-down substations are, the more daily feedback energy is utilized. When the start voltage of the EFS ranges from 1650 V to 1770 V, the maximum energy-saving rate reaches 11.9%, which occurs when the start voltage is 1670 V. When the no-load voltage is relatively high, the start voltage should not be higher than 1750 V to keep the system running in high efficiency. These results can provide advice for the design and operation of traction power supply systems with EFSs.
- 12 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 70 (10) , 9898-9909
Modified AC/DC Unified Power Flow and Energy-Saving Evaluation for Urban Rail Power Supply System With Energy Feedback Systems
Energy feedback systems (EFSs) have been widely applied in urban rail transit, and a power flow algorithm and energy-saving evaluation of urban rail power supply systems with EFSs are studied in this paper. First, trains, the reflux system, and traction substations with EFSs are modeled, and the multimode transitions are analyzed, including the maximum power state of the EFS. Then, a modified AC/DC unified power flow algorithm for the DC power supply system, which simplified the DC reflux system is proposed, and a field case study based on a multiple train scenario is presented to validate the algorithm. Furthermore, system-level energy-saving evaluation indexes are applied according to system power flow analysis. When the headway time decreases, the proposed indexes decrease in general mainly as there is more regenerative braking energy absorbed by adjacent trains. The higher the load rates of the step-down substations are, the more daily feedback energy is utilized. When the start voltage of the EFS ranges from 1650 V to 1770 V, the maximum energy-saving rate reaches 11.9%, which occurs when the start voltage is 1670 V. When the no-load voltage is relatively high, the start voltage should not be higher than 1750 V to keep the system running in high efficiency. These results can provide advice for the design and operation of traction power supply systems with EFSs.