FZFan Zhong

Fan Zhong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fan Zhong has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Chance-Constrained and CVaR Optimal Dispatch for Co-Phase Traction Power Supply System with PV and HESS

    by Shaofeng Xie, Jingyuan Qi, Hui Wang, Yuqiang Xu, Fan Zhong

    Co-phase traction power supply system (CTPSS) integrated with photovoltaic (PV) and hybrid energy storage system (HESS) can enhance power supply capacity while facilitating the on-site consumption of renewable energy. This integration provides a pathway toward green development and the achievement of the “carbon peaking and carbon neutrality” goal. However, the stochastic nature of PV poses challenges to safe and economical operation of the system. Existing energy management methods remain limited in simultaneously balancing operational economy and extreme risks caused by PV uncertainty, making it difficult to achieve an effective trade-off between operating cost and constraint violation risk. To address this issue, a risk-sensitive optimal scheduling framework integrating probabilistic PV forecasting, correlated scenario generation, and risk-aware optimization is developed. First, a PV probabilistic prediction model based on parallel TCN-BiLSTM-Attention is proposed, which extracts multiscale local features and long-range temporal features from PV for accurate uncertainty quantification. Second, a t-Copula PV scenario generation method driven by weather classification and temporal correlation is proposed. On this basis, a day-ahead optimal scheduling strategy integrating chance constraints programming (CCP) and conditional value at risk (CVaR) is established to simultaneously control constraint violation risk and extreme economic risk. The proposed prediction model can accurately quantify uncertainty, achieving an R2 value of 0.9979. When the allowable power supply loss probability is 0.5%, the proposed scheme’s operating cost is reduced by 1.36% compared with the baseline scheme. The results demonstrate that the proposed framework can effectively coordinate operating economy and extreme-risk control, thereby improving the risk-sensitive operational performance of CTPSS with PV and HESS. The proposed strategy balances economy and extreme risk, providing a reference for safe, low-carbon and economical operation of CTPSS with PV and HESS.

  • First-Order Impedance Model and Impedance-Frequency Analysis of Co-Phase Traction Power System Considering Control Coordinates and Integrated Compensation

    by Fan Zhong, Shaofeng Xie

    The co-phase traction power system (CTPS) has attracted widespread attention due to its advantages in solving power quality problems and eliminating the neutral section. However, the diversity of converter control strategies such as dq decoupling control (DQDC) and quasi-proportional resonant control (QPRC) involves different control coordinates, and the multi-dimensional compensation requirements including negative sequence, reactive power and harmonic compensation together pose challenges to the accurate description of the system's impedance characteristics. In view of this background, this paper focuses on the integrated compensation model and impedance-frequency characteristic analysis of CTPS. Firstly, a first-order impedance model is proposed for CTPS under DQDC and QPRC. Subsequently, the impedance dynamic response of the CTPS under operating conditions including traction energy fluctuation, reactive power compensation, full and selective compensation of voltage and current harmonics are investigated. The impedance maximum peaks and admittance maximum peaks involving phase characteristics are defined, and the low-frequency oscillation nature induced by these peaks is clarified. Finally, verification is conducted through control hardware-in-the-loop experiments, and the effects of the co-phase compensator on impedance and admittance modifications as well as oscillation suppression are investigated.

  • Unified Analysis of Low‐Frequency Oscillation and High‐Frequency Resonance in Train‐Network System Considering Decoupled Model of AC–DC Converter

    by Fan Zhong, Shaofeng Xie

    Low‐frequency oscillation (LFO) and harmonic resonance (HR) caused by AC – DC converters in train‐network system (TNS) degrade power quality, and threaten operational safety. This paper conducts a unified assessment based on the commonalities between LFO and HR. First, based on harmonic linearization, first‐order decoupled models for LFO and HR are established, respectively, through disturbance frequency approximation. Next, through feature extraction, evaluation indices oscillation gain (OG) and oscillation frequency (OF) are defined and solved. The amplification effect of train oscillation transmission in the network on the voltage harmonics of traction substations is quantified. Meanwhile, combined with the division of active/passive systems to reconstruct the system structure, the recovery time (RT) is derived, which reflects the RT after oscillation occurs when the train raises its pantographs to draw power. Furthermore, an oscillation indices prediction model is built to predict the oscillation trend. Finally, security domains for LFO and HR are designed according to standards and evaluation indices, and the proposed method is verified through engineering test and hardware‐in‐the‐loop experiment.

  • Wide-Band Oscillation Analysis of Railway Power Conditioner-Network-Train Coupling Power System Considering Energy Flow Modes

    by Fan Zhong, Shaofeng Xie, Xinyao Hu, Hui Wang, You Peng, Minwu Chen

    Railway power conditioner (RPC) is one of the most effective devices in electrified railways for the compensation of negative sequence, reactive power and the utilization of regenerative braking energy. However, the access of RPC will make the railway power supply system exhibit different energy flow modes, which will render the existing principles about wide-band oscillation characteristics opaque (low-frequency oscillation and high-frequency resonance), and increase the difficulty of analysis. The objective of this paper is to present a comprehensive analysis of the wide-band oscillation issue in the RPC-network-train coupling system. Initially, based on the dq decomposition method and mirror-frequency method, a unified impedance model for the system is established considering diverse energy flow modes. Subsequently, the wide-band oscillation distribution is obtained based on the modal decomposition method, thereby revealing the coupling mechanism between the RPC and the existing railway system. The security domain is delineated by further locating the key components affecting the wide-band oscillation based on the sensitivity of the parameters to the frequency and amplitude of the oscillation. Finally, the correctness of the analysis result is verified on the simulation platform and StarSim hardware-in-the-loop experimental platform.


  • Open Access

    A novel harmonic resonance prevention measure for railway power conditioner–network–train interaction system

    by Shaofeng Xie, Fan Zhong

    The integration of a large number of power electronic converters, such as railway power conditioner (RPC), introduces a series of problems, including harmonic interaction, stability issues, and wideband resonance, into the railway power supply system. To address these challenges, this paper proposes a novel harmonic resonance prevention measure for RPC–network–train interaction system. Firstly, a harmonic model, a parallel resonance impedance model, a series resonance admittance model, and a control stability model are each established for the RPC–network–train interaction system. Secondly, a comprehensive resonance impact factor (CRIF) is proposed to efficiently and accurately identify the key components affecting resonance, and to provide the selection results of optimization parameters for resonance prevention. Next, the initially selected parameters are constrained by the requirements of ripple current, reactive power and stability. Subsequently, the impedance parameters (control parameters and filter parameters) of the RPC are optimized with the objective of reshaping the parallel resonance impedance and series resonance admittance of the RPC–network–train interaction system, ensuring the output current harmonics of RPC meet standards to achieve resonance prevention, while ensuring the stable operation of the RPC. Finally, the proposed resonance prevention measure is verified under both light load and heavy load conditions using a simulation platform and a hardware-in-the-loop experimental platform.


  • Advanced Single-Phase to Three-Phase Power Conversion Systems for Medium and Low Voltage Single-Phase AC Systems in Remote Areas

    by You Peng, Xiaohong Huang, Shaofeng Xie, Fan Zhong

    Single-phase medium or low voltage distribution networks remain the predominant choice in remote or rural areas, largely due to historical and economic considerations. As economic development progresses, the demand for high-quality three-phase power systems in these regions has increased steadily. To address the challenge of providing three-phase power in remote areas, this article introduces a single-phase to three-phase power flow controller (1PH–3PH PFC) for medium and low voltage distribution networks. The proposed system includes a reverse YNd11 transformer and three half-bridge converters, which have been specifically designed to mitigate grid voltage disturbances, including sags, swells, and harmonics, that may impact loads. Furthermore, the system ensures unit power factor operation while eliminating harmonic currents from the loads. The control strategy incorporates output voltage feedforward and weighted average feedback of the filter inductor current, thereby enhancing system responsiveness. Furthermore, the power flow of apparent and active power under various voltage fluctuation scenarios is analyzed. The proposed scheme is validated through simulation and hardware-in-the-loop experiments. The research results indicate that, in comparison to the UPQC-1Ph–3Ph scheme, the 1PH–3PH PFC solution significantly reduces the converter design capacity, with potential savings of up to 60% of capacity under conditions of a 25% voltage sag.