Si Phu Me
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Si Phu Me has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Behrooz Bahrani
Department of Electrical and Computer Systems Engineering, Monash University, Clayton, VIC, Australia
6 shared publications - Sasan Zabihi
Department of Electrical and Computer Systems Engineering, Monash University, Clayton, VIC, Australia
6 shared publications Behrooz Bahrani
2 shared publicationsBruno Leonardi
2 shared publications- Dayan Bandara Rathnayake
Department of Electrical and Computer Systems Engineering, Monash University, Clayton, VIC, Australia
2 shared publications - Deepak Ramasubramanian
EPRI, Palo Alto, CA, USA
2 shared publications
Latest Publications
- Open Access
- 23 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Transient Stability Analysis of Virtual Synchronous Generator Equipped with Quadrature-Prioritized Current Limiter
A current limiter (CL), which protects virtual synchronous generators (VSGs) from overcurrents, may significantly alter the operation of the VSGs when activated. In this letter, a transient stability analysis of VSGs equipped with quadrature- (q-) prioritized CL is performed. This study shows that in addition to the instability caused by the positive feedback of the primary controller, a VSG could become unstable after large disturbances due to the failure of the inner voltage controller. In this study, a stability criterion is provided for the voltage control loop.
- 23 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessTransient Stability Analysis of Virtual Synchronous Generator Equipped with Quadrature-Prioritized Current Limiter
A current limiter (CL), which protects virtual synchronous generators (VSGs) from overcurrents, may significantly alter the operation of the VSGs when activated. In this letter, a transient stability analysis of VSGs equipped with quadrature- (q-) prioritized CL is performed. This study shows that in addition to the instability caused by the positive feedback of the primary controller, a VSG could become unstable after large disturbances due to the failure of the inner voltage controller. In this study, a stability criterion is provided for the voltage control loop.
- 22 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (9) , 10547-10553
Transient Stability Analysis of Virtual Synchronous Generator Equipped With Quadrature-Prioritized Current Limiter
A current limiter (CL), which protects virtual synchronous generators (VSGs) from overcurrents, may significantly alter the operation of the VSGs when activated. In this letter, a transient stability analysis of VSGs equipped with quadrature (q-)prioritized CL is performed. This study shows that in addition to the instability caused by the positive feedback of the primary controller, a VSG could become unstable after large disturbances due to the failure of the inner voltage controller. In this study, a stability criterion is provided for the voltage control loop.
- 22 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (9) , 10547-10553
Transient Stability Analysis of Virtual Synchronous Generator Equipped With Quadrature-Prioritized Current Limiter
A current limiter (CL), which protects virtual synchronous generators (VSGs) from overcurrents, may significantly alter the operation of the VSGs when activated. In this letter, a transient stability analysis of VSGs equipped with quadrature (q-)prioritized CL is performed. This study shows that in addition to the instability caused by the positive feedback of the primary controller, a VSG could become unstable after large disturbances due to the failure of the inner voltage controller. In this study, a stability criterion is provided for the voltage control loop.
- Open Access
- 27 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Transient Stability of Paralleled Virtual Synchronous Generator and Grid-following Inverter
The majority of inverter-based resources (IBRs) currently operate as grid-following inverters (GFLIs). These inverters exhibit certain stability issues when integrated in low-strength areas of the grid. To enhance the grid strength in a GFLI-dominant area, virtual synchronous generators (VSGs) are installed. If the VSG and the GFLI are investigated as a paralleled system, despite the benefits brought by the VSG, in some cases, the transient angle instability process, caused by a voltage sag, is accelerated. Therefore, this paper studies the transient angle stability of a paralleled VSG-GFLI system via investigating the voltage at a common bus between the two IBRs. Subsequently, a stable region of the voltage angles of the two IBRs is determined. Based on this region, the stability margin of the paralleled system can be determined and used to quantitatively evaluate the system stability. Moreover, a control loop is proposed to improve the transient stability of the paralleled system. The proposed controller can adaptively reduce the VSG power set-point to avoid a complete failure of the VSG even when no stable equilibrium point exists during a voltage sag. The stability investigation and performance evaluation of the proposed method are conducted in PSCAD/EMTDC and experimentally validated.
- 27 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessTransient Stability of Paralleled Virtual Synchronous Generator and Grid-following Inverter
The majority of inverter-based resources (IBRs) currently operate as grid-following inverters (GFLIs). These inverters exhibit certain stability issues when integrated in low-strength areas of the grid. To enhance the grid strength in a GFLI-dominant area, virtual synchronous generators (VSGs) are installed. If the VSG and the GFLI are investigated as a paralleled system, despite the benefits brought by the VSG, in some cases, the transient angle instability process, caused by a voltage sag, is accelerated. Therefore, this paper studies the transient angle stability of a paralleled VSG-GFLI system via investigating the voltage at a common bus between the two IBRs. Subsequently, a stable region of the voltage angles of the two IBRs is determined. Based on this region, the stability margin of the paralleled system can be determined and used to quantitatively evaluate the system stability. Moreover, a control loop is proposed to improve the transient stability of the paralleled system. The proposed controller can adaptively reduce the VSG power set-point to avoid a complete failure of the VSG even when no stable equilibrium point exists during a voltage sag. The stability investigation and performance evaluation of the proposed method are conducted in PSCAD/EMTDC and experimentally validated.
- 9 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 14 (6) , 4451-4466
Transient Stability of Paralleled Virtual Synchronous Generator and Grid-Following Inverter
The majority of inverter-based resources (IBRs) currently operate as grid-following inverters (GFLIs). However, these inverters exhibit certain stability issues when integrated in low-strength areas of the grid. To enhance the grid strength in a GFLI-dominant area, virtual synchronous generators (VSGs) can be installed. If the VSG and the GFLI are investigated as a paralleled system, despite the benefits brought by the VSG, in some cases, the transient angle instability process, caused by a voltage sag, is accelerated, making the whole system more prone to instability. Therefore, this paper aims to study the transient angle stability of a paralleled VSG-GFLI system via investigating the voltage at a common bus between the two IBRs. Subsequently, a stable region of the voltage angles of the two IBRs is determined. Based on this stable region, the stability margin of the paralleled system can be determined and used to quantitatively evaluate the system stability. Moreover, an additional control loop is proposed to improve the transient stability of the paralleled system in this paper. The proposed controller can adaptively reduce the power set-point of the VSG to avoid a complete failure of the VSG even when no stable equilibrium point exists during a voltage sag. The stability investigation and performance evaluation of the proposed method are conducted in PSCAD/EMTDC and experimentally validated.
- 9 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 14 (6) , 4451-4466
Transient Stability of Paralleled Virtual Synchronous Generator and Grid-Following Inverter
The majority of inverter-based resources (IBRs) currently operate as grid-following inverters (GFLIs). However, these inverters exhibit certain stability issues when integrated in low-strength areas of the grid. To enhance the grid strength in a GFLI-dominant area, virtual synchronous generators (VSGs) can be installed. If the VSG and the GFLI are investigated as a paralleled system, despite the benefits brought by the VSG, in some cases, the transient angle instability process, caused by a voltage sag, is accelerated, making the whole system more prone to instability. Therefore, this paper aims to study the transient angle stability of a paralleled VSG-GFLI system via investigating the voltage at a common bus between the two IBRs. Subsequently, a stable region of the voltage angles of the two IBRs is determined. Based on this stable region, the stability margin of the paralleled system can be determined and used to quantitatively evaluate the system stability. Moreover, an additional control loop is proposed to improve the transient stability of the paralleled system in this paper. The proposed controller can adaptively reduce the power set-point of the VSG to avoid a complete failure of the VSG even when no stable equilibrium point exists during a voltage sag. The stability investigation and performance evaluation of the proposed method are conducted in PSCAD/EMTDC and experimentally validated.
- 14 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (2) , 2311-2325
H∞-Based Control Design for Grid-Forming Inverters With Enhanced Damping and Virtual Inertia
Grid-forming inverters (GFMIs) are identified as an important asset for achieving renewable energy-rich power grids. GFMIs are attracting significant attention due to their superior characteristics over grid-following inverters in both grid-connected (GC) and standalone (SA) scenarios. In this paper, a second-order discrete-time controller is proposed to achieve a well-damped step response for power reference commands and improved virtual inertia provision capability. In this paper, a control design method based on H∞ is proposed, which is based on the frequency response of the system, to tune the proposed controller. The proposed control design presents a methodical process to specify the desired performance indices through frequency-domain constraints. The performance of the controller is thoroughly validated analytically and through simulation results. The superior performance of the proposed controller over the virtual synchronous generator controller in terms of tracking performance and virtual inertia provision capability is verified through experimental results.
- 14 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (2) , 2311-2325
H∞-Based Control Design for Grid-Forming Inverters With Enhanced Damping and Virtual Inertia
Grid-forming inverters (GFMIs) are identified as an important asset for achieving renewable energy-rich power grids. GFMIs are attracting significant attention due to their superior characteristics over grid-following inverters in both grid-connected (GC) and standalone (SA) scenarios. In this paper, a second-order discrete-time controller is proposed to achieve a well-damped step response for power reference commands and improved virtual inertia provision capability. In this paper, a control design method based on H∞ is proposed, which is based on the frequency response of the system, to tune the proposed controller. The proposed control design presents a methodical process to specify the desired performance indices through frequency-domain constraints. The performance of the controller is thoroughly validated analytically and through simulation results. The superior performance of the proposed controller over the virtual synchronous generator controller in terms of tracking performance and virtual inertia provision capability is verified through experimental results.
- 8 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (4) , 3813-3824
Adaptive Virtual Resistance for Postfault Oscillation Damping in Grid-Forming Inverters
Postfault oscillations in active power and voltage responses of grid-connected voltage source inverters (VSIs) have been reported in the literature. They are caused by nonideally tuned controllers and the implemented current limitations used for protecting the VSIs from overcurrents. These oscillations become even more significant when the VSI is connected to a weak grid, deteriorating the recovery process of the VSI. This article presents a method for damping the postfault oscillations by using an adaptive virtual resistor (VR). Even though these oscillations are observed with both grid-following and grid-forming inverters, this article focuses on droop-based grid-forming inverters. The proposed method dynamically integrates a VR into the VSI control and removes it in the normal operation mode of the VSI. This method is implemented in the synchronous reference frame, which is commonly used due to its decoupled active and reactive power control. The amount of virtual resistance used for oscillation damping is adaptive to the recovery rate of the VSI. Hence, the proposed method is robust against changes in grid strength. Finally, the performance of the method is evaluated in PSCAD/EMTDC and also experimentally validated.
- 8 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (4) , 3813-3824
Adaptive Virtual Resistance for Postfault Oscillation Damping in Grid-Forming Inverters
Postfault oscillations in active power and voltage responses of grid-connected voltage source inverters (VSIs) have been reported in the literature. They are caused by nonideally tuned controllers and the implemented current limitations used for protecting the VSIs from overcurrents. These oscillations become even more significant when the VSI is connected to a weak grid, deteriorating the recovery process of the VSI. This article presents a method for damping the postfault oscillations by using an adaptive virtual resistor (VR). Even though these oscillations are observed with both grid-following and grid-forming inverters, this article focuses on droop-based grid-forming inverters. The proposed method dynamically integrates a VR into the VSI control and removes it in the normal operation mode of the VSI. This method is implemented in the synchronous reference frame, which is commonly used due to its decoupled active and reactive power control. The amount of virtual resistance used for oscillation damping is adaptive to the recovery rate of the VSI. Hence, the proposed method is robust against changes in grid strength. Finally, the performance of the method is evaluated in PSCAD/EMTDC and also experimentally validated.
- Top Cited PapersOpen Access
- 13 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 114781-114807
Grid Forming Inverter Modeling, Control, and Applications
This paper surveys current literature on modeling methods, control techniques, protection schemes, applications, and real-world implementations pertaining to grid forming inverters (GFMIs). Electric power systems are increasingly being augmented with inverter-based resources (IBRs). While having a growing share of IBRs, conventional synchronous generator-based voltage and frequency control mechanisms are still prevalent in the power industry. Therefore, IBRs are experiencing a growing demand for mimicking the behavior of synchronous generators, which is not possible with conventional grid following inverters (GFLIs). As a solution, the concept of GFMIs is currently emerging, which is drawing increased attention from academia and the industry. This paper presents a comprehensive review of GFMIs covering recent advancements in control technologies, fault ride-through capabilities, stability enhancement measures, and practical implementations. Moreover, the challenges in adding GFMIs into existing power systems, including a seamless transition from grid-connected mode to the standalone mode and vice versa, are also discussed in detail. Recently commissioned projects in Australia, the UK, and the US are taken as examples to highlight the trend in the power industry in adding GFMIs to address issues related to weak grid scenarios. Research directions in terms of voltage control, frequency control, system strength improvement, and regulatory framework are also discussed. This paper serves as a resource for researchers and power system engineers exploring solutions to the emerging problems with high penetration of IBRs, focusing on GFMIs.
- 13 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 114781-114807
Top Cited PapersOpen AccessGrid Forming Inverter Modeling, Control, and Applications
This paper surveys current literature on modeling methods, control techniques, protection schemes, applications, and real-world implementations pertaining to grid forming inverters (GFMIs). Electric power systems are increasingly being augmented with inverter-based resources (IBRs). While having a growing share of IBRs, conventional synchronous generator-based voltage and frequency control mechanisms are still prevalent in the power industry. Therefore, IBRs are experiencing a growing demand for mimicking the behavior of synchronous generators, which is not possible with conventional grid following inverters (GFLIs). As a solution, the concept of GFMIs is currently emerging, which is drawing increased attention from academia and the industry. This paper presents a comprehensive review of GFMIs covering recent advancements in control technologies, fault ride-through capabilities, stability enhancement measures, and practical implementations. Moreover, the challenges in adding GFMIs into existing power systems, including a seamless transition from grid-connected mode to the standalone mode and vice versa, are also discussed in detail. Recently commissioned projects in Australia, the UK, and the US are taken as examples to highlight the trend in the power industry in adding GFMIs to address issues related to weak grid scenarios. Research directions in terms of voltage control, frequency control, system strength improvement, and regulatory framework are also discussed. This paper serves as a resource for researchers and power system engineers exploring solutions to the emerging problems with high penetration of IBRs, focusing on GFMIs.
- Top Cited Papers
- 8 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (3) , 2699-2709
Nonlinear Transient Stability Analysis of Phased-Locked Loop-Based Grid-Following Voltage-Source Converters Using Lyapunov’s Direct Method
In this article, using Lyapunov’s stability theorem, the transient stability conditions for a grid-following voltage-source converter (VSC) are found. These conditions take into account both the grid specifications and the VSC’s dynamics. The derived conditions are based on a well-known nonlinear model of the VSC’s phase-locked loop. To evaluate the stability of the nonlinear system, Lyapunov’s direct method is employed. To this end, a new Lyapunov’s function is proposed, and its characteristics are analyzed. Using this Lyapunov’s function, the domain of attraction of the system’s equilibrium point is calculated. In addition, a novel system strength index based on the domain of attraction of the system is proposed. The privileges of this index over the conventional indices are absoluteness, VSC’s dynamics consideration, and comparability of different VSCs with each other from a stability point of view. In the end, the correctness of the proposed stability analysis is validated via simulation in MATLAB/PLECS and experiment.
- 8 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (3) , 2699-2709
Top Cited PapersNonlinear Transient Stability Analysis of Phased-Locked Loop-Based Grid-Following Voltage-Source Converters Using Lyapunov’s Direct Method
In this article, using Lyapunov’s stability theorem, the transient stability conditions for a grid-following voltage-source converter (VSC) are found. These conditions take into account both the grid specifications and the VSC’s dynamics. The derived conditions are based on a well-known nonlinear model of the VSC’s phase-locked loop. To evaluate the stability of the nonlinear system, Lyapunov’s direct method is employed. To this end, a new Lyapunov’s function is proposed, and its characteristics are analyzed. Using this Lyapunov’s function, the domain of attraction of the system’s equilibrium point is calculated. In addition, a novel system strength index based on the domain of attraction of the system is proposed. The privileges of this index over the conventional indices are absoluteness, VSC’s dynamics consideration, and comparability of different VSCs with each other from a stability point of view. In the end, the correctness of the proposed stability analysis is validated via simulation in MATLAB/PLECS and experiment.