Juzhe Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Juzhe Li has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Xu Liu
Beijing University of Technology
2 shared publications - Minkyu Je
Korea Advanced Institute of Science and Technology (KAIST)
1 shared publication - Peiyuan Wan
Beijing University of Technology
1 shared publication - Tao Chen
School of Physics and Optoelectronic Engineering, Beijing University of Technology, Beijing 100124, China
1 shared publication - Weijian Chen
College of Microelectronics, Beijing University of Technology, Beijing, China
1 shared publication - Wensi Wang
Faculty of Information Technology, Beijing University of Technology, Beijing 100124, China
1 shared publication
Latest Publications
- 22 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (5) , 1037-1049
A 4-Channel Neural Stimulation IC Design With Charge Balancing and Multiple Current Output Modes
This paper proposes a neural stimulation integrated circuit design with multiple current output modes. In the cathodic stimulation phase and anodic stimulation phase, each output current waveform can be independently selected to either exponential waveform or square wave, so the stimulator holds four stimulation modes. To minimize the headroom voltage of the output stage and enhance the power efficiency of the proposed stimulator, we introduce the exponentially decaying current which is realized by the exponential current generation circuit in this work. It can enhance the longer duration of the stimulation pulse as well. In case the residual charge may cause harm to patients, a charge balancing technique is implemented in this work for all operation modes. The four-channel stimulator IC is implemented in a 180-nm CMOS process, occupying a core area of 1.93 mm 2 . The measurement results show that the proposed stimulator realized a maximum power efficiency of 91.3% and the maximum stimulation duration is 3 times larger than previous works. Moreover, even in exponential output waveform mode, the maximum residual charge in a single cycle is only 255 pC due to the proposed charge balancing technique. The experiment results based on the PBS solution also show that the stimulator IC can remove residual charges within 60 μs, and the electrode voltage remains stable within a safe range under multicycle stimulation.
- 22 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (5) , 1037-1049
A 4-Channel Neural Stimulation IC Design With Charge Balancing and Multiple Current Output Modes
This paper proposes a neural stimulation integrated circuit design with multiple current output modes. In the cathodic stimulation phase and anodic stimulation phase, each output current waveform can be independently selected to either exponential waveform or square wave, so the stimulator holds four stimulation modes. To minimize the headroom voltage of the output stage and enhance the power efficiency of the proposed stimulator, we introduce the exponentially decaying current which is realized by the exponential current generation circuit in this work. It can enhance the longer duration of the stimulation pulse as well. In case the residual charge may cause harm to patients, a charge balancing technique is implemented in this work for all operation modes. The four-channel stimulator IC is implemented in a 180-nm CMOS process, occupying a core area of 1.93 mm 2 . The measurement results show that the proposed stimulator realized a maximum power efficiency of 91.3% and the maximum stimulation duration is 3 times larger than previous works. Moreover, even in exponential output waveform mode, the maximum residual charge in a single cycle is only 255 pC due to the proposed charge balancing technique. The experiment results based on the PBS solution also show that the stimulator IC can remove residual charges within 60 μs, and the electrode voltage remains stable within a safe range under multicycle stimulation.
- Open Access
- 27 August 2021
- Published by Wiley in Journal of Healthcare Engineering
- Vol. 2021, 1-11
A Neural Recording and Stimulation Chip with Artifact Suppression for Biomedical Devices
This paper presents chip implementation of the integrated neural recording and stimulation system with stimulation-induced artifact suppression. The implemented chip consists of low-power neural recording circuits, stimulation circuits, and action potential detection circuits. These circuits constitute a closed-loop simultaneous neural recording and stimulation system for biomedical devices, and a proposed artifact suppression technique is used in the system. Moreover, this paper also presents the measurement and experiment results of the implemented 4-to-4 channel neural recording and stimulation chip with 0.18µm CMOS technology. The function and efficacy of simultaneous neural recording and stimulation is validated in both in vivo and animal experiments.
- 27 August 2021
- Published by Wiley in Journal of Healthcare Engineering
- Vol. 2021, 1-11
Open AccessA Neural Recording and Stimulation Chip with Artifact Suppression for Biomedical Devices
This paper presents chip implementation of the integrated neural recording and stimulation system with stimulation-induced artifact suppression. The implemented chip consists of low-power neural recording circuits, stimulation circuits, and action potential detection circuits. These circuits constitute a closed-loop simultaneous neural recording and stimulation system for biomedical devices, and a proposed artifact suppression technique is used in the system. Moreover, this paper also presents the measurement and experiment results of the implemented 4-to-4 channel neural recording and stimulation chip with 0.18µm CMOS technology. The function and efficacy of simultaneous neural recording and stimulation is validated in both in vivo and animal experiments.