João Vitor Do Nascimento Santos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
João Vitor Do Nascimento Santos has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
- Rodrigo Othavio de Assuncao E Souza
Department of Dentistry Federal University of Rio Grande do Norte (UFRN) Natal Brazil
10 shared publications - Renally Bezerra Wanderley Lima
Department of Restorative Dentistry, Federal University of Paraíba (UFPB), João Pessoa, Paraíba, Brazil
8 shared publications - Juan Vitor Costa Leite
Dental Materials Division, Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas (FOP/UNICAMP), Piracicaba, São Paulo, Brazil
6 shared publications - Sarah Emille Gomes da Silva
Doctoral student, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, RN, Brazil
5 shared publications - Laryssa Mylenna Madruga Barbosa
Department of Restorative Dentistry, State University of Ponta Grossa, Paraná, Brazil; IDIBO Research Group, Rey Juan Carlos University, Alcorcón, Madrid, Spain
4 shared publications - Fernanda Gurgel de Gois Moreira
Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Brazil
3 shared publications
Latest Publications
- Open Access
- 11 August 2026
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 30 (9) , 382
Effect of different finishing/polishing protocols and aging on flexural strength, roughness, and surface characteristics of definitive restorative materials for CAD/CAM
Objective: To evaluate the effect of finishing/polishing and aging on the flexural strength, roughness, and surface characteristics of CAD/CAM restorative materials. Materials and methods: Three CAD/CAM materials were tested: Nanoceramic resin (CR), Polymer-infiltrated ceramic (PIC), and Leucite-reinforced glass-ceramic (LC). A total of 120 bars (8 × 2 × 1 mm; n = 15/group) were prepared and subjected to different finishing/polishing protocols (C: control; B: bur; BD: diamond bur + diamond-impregnated rubber tips; BS: diamond bur + silica-impregnated rubbers) and aging (without/with 10,000 thermocycles). Mini-flexural strength (σ) was assessed by three-point bending. Surface roughness (Sa) was analyzed using optical profilometry, while surface characterization was performed using SEM. Data were analyzed with two-way ANOVA/Tukey’s test (α = 0.05) and Weibull analysis. Results: For σ, both finishing/polishing and aging factors significantly affected PIC and LC ( p < 0.05), whereas only finishing/polishing influenced CR. In CR, aged CR_BD had the lowest strength (112.0 ± 17.9 MPa). In PIC, aged PIC_BS (121.8 ± 21.4) showed the highest strength, while PIC_BD groups showed the lowest. In LC, the highest values were seen in aged LC_C (125.7 ± 22.9), LC_B (114.75 ± 19.09), and non-aged LC_C (108.11 ± 29.54). Sa was significantly affected by material type and finishing/polishing protocols. Conclusions: Silica-impregnated rubbers improved the flexural strength of PIC after bur finishing. The BD protocol, producing smoother surfaces, may compromise the flexural strength of LC. In contrast, CR was not significantly affected by the polishing protocol. Moreover, aging negatively impacted PIC strength, and polyurethane rubber tips impregnated with diamond particles produced smoother surfaces after bur adjustments. Clinical relevance: Within the limitations of this in vitro study, polishing protocols should be selected according to material composition, since surface smoothness does not necessarily correlate with improved mechanical performance. For CR, all polishing systems showed comparable performance; for LC, minimal intervention or no polishing better preserved mechanical performance; for PIC, silica-based polishing systems may be preferred.
- 11 August 2026
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 30 (9) , 382
Open AccessEffect of different finishing/polishing protocols and aging on flexural strength, roughness, and surface characteristics of definitive restorative materials for CAD/CAM
Objective: To evaluate the effect of finishing/polishing and aging on the flexural strength, roughness, and surface characteristics of CAD/CAM restorative materials. Materials and methods: Three CAD/CAM materials were tested: Nanoceramic resin (CR), Polymer-infiltrated ceramic (PIC), and Leucite-reinforced glass-ceramic (LC). A total of 120 bars (8 × 2 × 1 mm; n = 15/group) were prepared and subjected to different finishing/polishing protocols (C: control; B: bur; BD: diamond bur + diamond-impregnated rubber tips; BS: diamond bur + silica-impregnated rubbers) and aging (without/with 10,000 thermocycles). Mini-flexural strength (σ) was assessed by three-point bending. Surface roughness (Sa) was analyzed using optical profilometry, while surface characterization was performed using SEM. Data were analyzed with two-way ANOVA/Tukey’s test (α = 0.05) and Weibull analysis. Results: For σ, both finishing/polishing and aging factors significantly affected PIC and LC ( p < 0.05), whereas only finishing/polishing influenced CR. In CR, aged CR_BD had the lowest strength (112.0 ± 17.9 MPa). In PIC, aged PIC_BS (121.8 ± 21.4) showed the highest strength, while PIC_BD groups showed the lowest. In LC, the highest values were seen in aged LC_C (125.7 ± 22.9), LC_B (114.75 ± 19.09), and non-aged LC_C (108.11 ± 29.54). Sa was significantly affected by material type and finishing/polishing protocols. Conclusions: Silica-impregnated rubbers improved the flexural strength of PIC after bur finishing. The BD protocol, producing smoother surfaces, may compromise the flexural strength of LC. In contrast, CR was not significantly affected by the polishing protocol. Moreover, aging negatively impacted PIC strength, and polyurethane rubber tips impregnated with diamond particles produced smoother surfaces after bur adjustments. Clinical relevance: Within the limitations of this in vitro study, polishing protocols should be selected according to material composition, since surface smoothness does not necessarily correlate with improved mechanical performance. For CR, all polishing systems showed comparable performance; for LC, minimal intervention or no polishing better preserved mechanical performance; for PIC, silica-based polishing systems may be preferred.
- Open Access
- 23 April 2026
- Published by Elsevier in International Journal of Adhesion and Adhesives
- Vol. 149
Bond strength of resin cement to multilayer graded zirconia after saliva and blood contamination with different cleaning protocols
- 23 April 2026
- Published by Elsevier in International Journal of Adhesion and Adhesives
- Vol. 149
Open AccessBond strength of resin cement to multilayer graded zirconia after saliva and blood contamination with different cleaning protocols
- Open Access
- 22 April 2026
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 40 (21) , 3659-3680
Influence of post-etching phosphoric acid cleaning on resin bond strength to glass-ceramics: a systematic review of in vitro studies
- 22 April 2026
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 40 (21) , 3659-3680
Open AccessInfluence of post-etching phosphoric acid cleaning on resin bond strength to glass-ceramics: a systematic review of in vitro studies
- 6 March 2026
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 136 (1) , e420-e427
Effects of different surface treatments and artificial aging on the dentin bond strength and failure modes of 3D printed and milled resins
- 6 March 2026
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 136 (1) , e420-e427
Effects of different surface treatments and artificial aging on the dentin bond strength and failure modes of 3D printed and milled resins
- 23 December 2025
- Published by Elsevier in The Journal of the American Dental Association
- Vol. 157 (4) , 367-382
Effect of finishing and polishing and aging protocols on the mechanical properties, surface characteristics, and Candida albicans adherence of 3-dimensional–printed and prefabricated dental resins for definitive restorations
- 23 December 2025
- Published by Elsevier in The Journal of the American Dental Association
- Vol. 157 (4) , 367-382
Effect of finishing and polishing and aging protocols on the mechanical properties, surface characteristics, and Candida albicans adherence of 3-dimensional–printed and prefabricated dental resins for definitive restorations
- 29 November 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (5) , e43-e52
Clinical and patient-reported outcomes of implant-retained overdentures fabricated by digital and conventional workflows: A systematic review of clinical studies
- 29 November 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (5) , e43-e52
Clinical and patient-reported outcomes of implant-retained overdentures fabricated by digital and conventional workflows: A systematic review of clinical studies
- 29 November 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (5) , e186-e194
Influence of print layer thickness, immersion time, and solution type on the color stainability, roughness, and microbial adhesion of different 3D printed resins
- 29 November 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (5) , e186-e194
Influence of print layer thickness, immersion time, and solution type on the color stainability, roughness, and microbial adhesion of different 3D printed resins
- 6 October 2025
- Published by Wiley in European Journal of Oral Sciences
- Vol. 133 (6) , e70042
3D‐printed resin materials for indirect restorations—a scoping review and evidence gap map
This review aimed to map the available scientific evidence regarding the physical–mechanical properties and clinical performance of 3D‐printed resins used for indirect restorations and identify research gaps. PRISMA guidelines were followed, with methodological details preregistered in the Open Science Framework. A literature search was conducted in May 2025 across PubMed/Medline, Scopus, Embase, and Web of Science, without restrictions on publication date or language. Studies evaluating the physico‐mechanical properties (color stability, flexural strength, surface roughness, and hardness) and clinical performance (esthetic, functional, or biological properties) of 3D‐printed resins for full or partial coverage restorations, whether permanent or provisional, were included. A total of 36 studies met the inclusion criteria, including 35 in vitro and 1 clinical trial. The most frequently analyzed resin for temporary restorations was C&B MFH (NextDent) ( n = 10), while for definitive restorations, VSC+ (Bego) ( n = 5) was the most frequently used. Nonetheless, further research is required to evaluate their clinical performance in both temporary and definitive restorations. The available evidence indicates that a wide variety of 3D‐printed resins are available for clinical use, mainly as provisional restorative materials. There is still no sufficient clinical evidence to support the use of 3D‐printed resins for indirect definitive restorations.
- 6 October 2025
- Published by Wiley in European Journal of Oral Sciences
- Vol. 133 (6) , e70042
3D‐printed resin materials for indirect restorations—a scoping review and evidence gap map
This review aimed to map the available scientific evidence regarding the physical–mechanical properties and clinical performance of 3D‐printed resins used for indirect restorations and identify research gaps. PRISMA guidelines were followed, with methodological details preregistered in the Open Science Framework. A literature search was conducted in May 2025 across PubMed/Medline, Scopus, Embase, and Web of Science, without restrictions on publication date or language. Studies evaluating the physico‐mechanical properties (color stability, flexural strength, surface roughness, and hardness) and clinical performance (esthetic, functional, or biological properties) of 3D‐printed resins for full or partial coverage restorations, whether permanent or provisional, were included. A total of 36 studies met the inclusion criteria, including 35 in vitro and 1 clinical trial. The most frequently analyzed resin for temporary restorations was C&B MFH (NextDent) ( n = 10), while for definitive restorations, VSC+ (Bego) ( n = 5) was the most frequently used. Nonetheless, further research is required to evaluate their clinical performance in both temporary and definitive restorations. The available evidence indicates that a wide variety of 3D‐printed resins are available for clinical use, mainly as provisional restorative materials. There is still no sufficient clinical evidence to support the use of 3D‐printed resins for indirect definitive restorations.
- 17 September 2025
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 29 (10) , 464
Bioactive glass products for the treatment of dentin hypersensitivity: a scoping review
To systematically map and synthesize the current scientific evidence on the active ingredients and effectiveness of bioactive glass-containing products for the treatment of dentin hypersensitivity, and to identify knowledge gaps. This scoping review followed PRISMA-ScR guidelines and was registered on the Open Science Framework platform. Searches were conducted in PubMed/MEDLINE, Embase, Scopus, and Web of Science up to March 2025. Studies of any evidence level investigating bioactive glasses, bioactive glass-ceramics, or related products for dentin hypersensitivity treatment, evaluating parameters like dentinal tubule occlusion, dental remineralization, or pain relief, were included. Descriptive analysis was applied to all included studies. A total of 72 studies were reviewed, primarily in vitro (n = 46), with randomized clinical trials (n = 17) and reviews (n = 9) also represented. Calcium sodium phosphosilicate was the most analyzed bioactive glass (n = 33), often compared with arginine, nano-hydroxyapatite, potassium nitrate, and strontium acetate formulations. Products were commonly presented as toothpaste (n = 39), powder (n = 14), and gel (n = 6). In vitro studies frequently reported benefits in dentinal tubule occlusion, predominantly assessed by scanning electron microscopy. Clinical studies demonstrated reductions in dentin hypersensitivity-related pain, commonly assessed using air jet or cold-water stimuli combined with Visual Analog Scale (VAS) scores or the Schiff Cold Air Sensitivity Scale (SCSS), with follow-up periods ranging from 1 to 11 weeks. Toothpaste containing calcium sodium phosphosilicate was the most extensively studied bioactive glass-based product for dentin hypersensitivity treatment, with in vitro evidence supporting its effectiveness. Additional clinical research is needed to confirm these findings. Bioactive glass products show promise in the treatment of dentin hypersensitivity. Given the variability in composition, evidence-based selection is key to ensuring effective treatment and improving patient outcomes.
- 17 September 2025
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 29 (10) , 464
Bioactive glass products for the treatment of dentin hypersensitivity: a scoping review
To systematically map and synthesize the current scientific evidence on the active ingredients and effectiveness of bioactive glass-containing products for the treatment of dentin hypersensitivity, and to identify knowledge gaps. This scoping review followed PRISMA-ScR guidelines and was registered on the Open Science Framework platform. Searches were conducted in PubMed/MEDLINE, Embase, Scopus, and Web of Science up to March 2025. Studies of any evidence level investigating bioactive glasses, bioactive glass-ceramics, or related products for dentin hypersensitivity treatment, evaluating parameters like dentinal tubule occlusion, dental remineralization, or pain relief, were included. Descriptive analysis was applied to all included studies. A total of 72 studies were reviewed, primarily in vitro (n = 46), with randomized clinical trials (n = 17) and reviews (n = 9) also represented. Calcium sodium phosphosilicate was the most analyzed bioactive glass (n = 33), often compared with arginine, nano-hydroxyapatite, potassium nitrate, and strontium acetate formulations. Products were commonly presented as toothpaste (n = 39), powder (n = 14), and gel (n = 6). In vitro studies frequently reported benefits in dentinal tubule occlusion, predominantly assessed by scanning electron microscopy. Clinical studies demonstrated reductions in dentin hypersensitivity-related pain, commonly assessed using air jet or cold-water stimuli combined with Visual Analog Scale (VAS) scores or the Schiff Cold Air Sensitivity Scale (SCSS), with follow-up periods ranging from 1 to 11 weeks. Toothpaste containing calcium sodium phosphosilicate was the most extensively studied bioactive glass-based product for dentin hypersensitivity treatment, with in vitro evidence supporting its effectiveness. Additional clinical research is needed to confirm these findings. Bioactive glass products show promise in the treatment of dentin hypersensitivity. Given the variability in composition, evidence-based selection is key to ensuring effective treatment and improving patient outcomes.