Fernanda Gurgel de Gois Moreira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Fernanda Gurgel de Gois Moreira has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Rodrigo Othavio de Assuncao E Souza
Department of Dentistry Federal University of Rio Grande do Norte (UFRN) Natal Brazil
7 shared publications - João Vitor Do Nascimento Santos
Department of Dentistry, Federal University of Rio Grande do Norte, Natal, Rio Grande do Norte, Brazil
3 shared publications - Sarah Emille Gomes da Silva
Doctoral student, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, RN, Brazil
3 shared publications - Anne Heloyse Teixeira Crispim
Federal University of Rio Grande do Norte, Brazil
2 shared publications - Larissa Mendonça de Miranda
Department of Dentistry Federal University of Rio Grande do Norte (UFRN) Natal Brazil
2 shared publications - Marcella Guedes Pereira Gouvêa Bezerra
Department of Dentistry, Federal University of Rio Grande Do Norte (UFRN), Av. Salgado Filho Lagoa Nova, Natal, Rio Grande do Norte, 1787CEP: 59056-000, Brazil
2 shared publications
Latest Publications
- Open Access
- 11 August 2026
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 30 (9) , 382
Effect of different finishing/polishing protocols and aging on flexural strength, roughness, and surface characteristics of definitive restorative materials for CAD/CAM
Objective: To evaluate the effect of finishing/polishing and aging on the flexural strength, roughness, and surface characteristics of CAD/CAM restorative materials. Materials and methods: Three CAD/CAM materials were tested: Nanoceramic resin (CR), Polymer-infiltrated ceramic (PIC), and Leucite-reinforced glass-ceramic (LC). A total of 120 bars (8 × 2 × 1 mm; n = 15/group) were prepared and subjected to different finishing/polishing protocols (C: control; B: bur; BD: diamond bur + diamond-impregnated rubber tips; BS: diamond bur + silica-impregnated rubbers) and aging (without/with 10,000 thermocycles). Mini-flexural strength (σ) was assessed by three-point bending. Surface roughness (Sa) was analyzed using optical profilometry, while surface characterization was performed using SEM. Data were analyzed with two-way ANOVA/Tukey’s test (α = 0.05) and Weibull analysis. Results: For σ, both finishing/polishing and aging factors significantly affected PIC and LC ( p < 0.05), whereas only finishing/polishing influenced CR. In CR, aged CR_BD had the lowest strength (112.0 ± 17.9 MPa). In PIC, aged PIC_BS (121.8 ± 21.4) showed the highest strength, while PIC_BD groups showed the lowest. In LC, the highest values were seen in aged LC_C (125.7 ± 22.9), LC_B (114.75 ± 19.09), and non-aged LC_C (108.11 ± 29.54). Sa was significantly affected by material type and finishing/polishing protocols. Conclusions: Silica-impregnated rubbers improved the flexural strength of PIC after bur finishing. The BD protocol, producing smoother surfaces, may compromise the flexural strength of LC. In contrast, CR was not significantly affected by the polishing protocol. Moreover, aging negatively impacted PIC strength, and polyurethane rubber tips impregnated with diamond particles produced smoother surfaces after bur adjustments. Clinical relevance: Within the limitations of this in vitro study, polishing protocols should be selected according to material composition, since surface smoothness does not necessarily correlate with improved mechanical performance. For CR, all polishing systems showed comparable performance; for LC, minimal intervention or no polishing better preserved mechanical performance; for PIC, silica-based polishing systems may be preferred.
- 11 August 2026
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 30 (9) , 382
Open AccessEffect of different finishing/polishing protocols and aging on flexural strength, roughness, and surface characteristics of definitive restorative materials for CAD/CAM
Objective: To evaluate the effect of finishing/polishing and aging on the flexural strength, roughness, and surface characteristics of CAD/CAM restorative materials. Materials and methods: Three CAD/CAM materials were tested: Nanoceramic resin (CR), Polymer-infiltrated ceramic (PIC), and Leucite-reinforced glass-ceramic (LC). A total of 120 bars (8 × 2 × 1 mm; n = 15/group) were prepared and subjected to different finishing/polishing protocols (C: control; B: bur; BD: diamond bur + diamond-impregnated rubber tips; BS: diamond bur + silica-impregnated rubbers) and aging (without/with 10,000 thermocycles). Mini-flexural strength (σ) was assessed by three-point bending. Surface roughness (Sa) was analyzed using optical profilometry, while surface characterization was performed using SEM. Data were analyzed with two-way ANOVA/Tukey’s test (α = 0.05) and Weibull analysis. Results: For σ, both finishing/polishing and aging factors significantly affected PIC and LC ( p < 0.05), whereas only finishing/polishing influenced CR. In CR, aged CR_BD had the lowest strength (112.0 ± 17.9 MPa). In PIC, aged PIC_BS (121.8 ± 21.4) showed the highest strength, while PIC_BD groups showed the lowest. In LC, the highest values were seen in aged LC_C (125.7 ± 22.9), LC_B (114.75 ± 19.09), and non-aged LC_C (108.11 ± 29.54). Sa was significantly affected by material type and finishing/polishing protocols. Conclusions: Silica-impregnated rubbers improved the flexural strength of PIC after bur finishing. The BD protocol, producing smoother surfaces, may compromise the flexural strength of LC. In contrast, CR was not significantly affected by the polishing protocol. Moreover, aging negatively impacted PIC strength, and polyurethane rubber tips impregnated with diamond particles produced smoother surfaces after bur adjustments. Clinical relevance: Within the limitations of this in vitro study, polishing protocols should be selected according to material composition, since surface smoothness does not necessarily correlate with improved mechanical performance. For CR, all polishing systems showed comparable performance; for LC, minimal intervention or no polishing better preserved mechanical performance; for PIC, silica-based polishing systems may be preferred.
- 23 December 2025
- Published by Elsevier in The Journal of the American Dental Association
- Vol. 157 (4) , 367-382
Effect of finishing and polishing and aging protocols on the mechanical properties, surface characteristics, and Candida albicans adherence of 3-dimensional–printed and prefabricated dental resins for definitive restorations
- 23 December 2025
- Published by Elsevier in The Journal of the American Dental Association
- Vol. 157 (4) , 367-382
Effect of finishing and polishing and aging protocols on the mechanical properties, surface characteristics, and Candida albicans adherence of 3-dimensional–printed and prefabricated dental resins for definitive restorations
- 1 February 2025
- Published by Springer Nature in Odontology
- Vol. 113 (3) , 1165-1179
Influence of build angle, printing layer thickness and aging on the flexural strength, precision, roughness and porosity analysis of a printed resin for provisional restorations
Evaluate the impact of printing parameters on flexural strength (σ), flexural modulus (E), precision, and surface topography characteristics of a resin used to produce provisional restorations. 450 bars for provisional restorations were printed using the SLA printing (25 × 2x2mm ISO-4049), and randomly divided into 30 groups (n = 15) according to the following factors: “printing layer thickness” (25 μm;50 μm;100 μm), “Build angle” (0°,30°,45°,60°,90°) and “thermocycling-TC” (with or without). Following printing, the samples underwent cleaning with isopropyl alcohol. Photopolymerization was performed for 15 min with an UV lamp. Subsequently, each bar was assessed using a digital caliper at 11 specific points in three dimensions for comparison with the STL file area for precision analysis. Half of the samples underwent thermocycling. All samples were submitted to the σ test. Data for σ (MPa), and (GPa) and precision (mm) were analyzed using 3 and 2-way ANOVA, respectively, and Tukey’s post hoc test (5%). Micro-CT, 3D profilometry, and SEM were also performed and analyzed descriptively. The 90°/25μmTC (63.0 ± 4.5) showed the highest σ, being only statistically similar to the 45°/25μmTC (57.7 ± 3.1). For precision 0°/25 μm (–2.56 ± 0.04) expressed the greatest variation to the other experimental groups with a sample shrinkage of 25.6% compared to the STL file. The profilometry revealed that the 30º/25 μm group showed prominent peaks and valleys, presenting elevated roughness values with an average of Sa (28.25 μm). Moreover, it was observed that the groups with a 60° angle presented the lowest porosity values. A print layer thickness of 25 μm combined with a build angle of 90º and 45º resulted in higher σ and greater precision.
- 1 February 2025
- Published by Springer Nature in Odontology
- Vol. 113 (3) , 1165-1179
Influence of build angle, printing layer thickness and aging on the flexural strength, precision, roughness and porosity analysis of a printed resin for provisional restorations
Evaluate the impact of printing parameters on flexural strength (σ), flexural modulus (E), precision, and surface topography characteristics of a resin used to produce provisional restorations. 450 bars for provisional restorations were printed using the SLA printing (25 × 2x2mm ISO-4049), and randomly divided into 30 groups (n = 15) according to the following factors: “printing layer thickness” (25 μm;50 μm;100 μm), “Build angle” (0°,30°,45°,60°,90°) and “thermocycling-TC” (with or without). Following printing, the samples underwent cleaning with isopropyl alcohol. Photopolymerization was performed for 15 min with an UV lamp. Subsequently, each bar was assessed using a digital caliper at 11 specific points in three dimensions for comparison with the STL file area for precision analysis. Half of the samples underwent thermocycling. All samples were submitted to the σ test. Data for σ (MPa), and (GPa) and precision (mm) were analyzed using 3 and 2-way ANOVA, respectively, and Tukey’s post hoc test (5%). Micro-CT, 3D profilometry, and SEM were also performed and analyzed descriptively. The 90°/25μmTC (63.0 ± 4.5) showed the highest σ, being only statistically similar to the 45°/25μmTC (57.7 ± 3.1). For precision 0°/25 μm (–2.56 ± 0.04) expressed the greatest variation to the other experimental groups with a sample shrinkage of 25.6% compared to the STL file. The profilometry revealed that the 30º/25 μm group showed prominent peaks and valleys, presenting elevated roughness values with an average of Sa (28.25 μm). Moreover, it was observed that the groups with a 60° angle presented the lowest porosity values. A print layer thickness of 25 μm combined with a build angle of 90º and 45º resulted in higher σ and greater precision.
- 19 October 2024
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 28 (11) , 1-19
Influence of 3D printing system, postpolymerization and aging protocols on resin flexural strength and dimensional stability for printing occlusal splints, models and temporary restorations
Objectives Investigate the effect of different postpolymerization protocols, aging, and 3D printing systems on the flexural strength (σ), dimensional stability, and roughness of resins used to fabricate occlusal splints, dental models, and temporary restorations. Material and methods 180 bars (25 × 2 x 2 mm—ISO 4049) of each type of resin (T—Temporary/Cosmos Temp, Yller; OS—Occlusal splint/Cosmos Splint, Yller; MO – Models/ Cosmos Model, Yller) were printed and divided into 12 groups (n = 15) according to the factors: “Postpolymerization” (Ctr – Control; UV – Ultraviolet oven and MW – Microwave); “Printer” (SLA- stereolithography (Forms 2/Formslab); LCD- liquid crystal display (FlashForge Foto 6.0/FlashForge)) and “Aging” (TC – 10,000 thermocycling cycles and Without). Each bar was measured with a digital caliper at 11 points before and after postpolymerization to evaluate dimensional stability. The samples were subjected to the σ test (100Kgf;1 mm/min). Data was evaluated using Three- and Two-way ANOVA, and Tukey’s test (5%). Weibull analysis, Scanning Electron Microscopic and optical profilometry was performed. Results LCD printing system and UV oven postpolymerization exhibited the highest σ (P < .05). The groups printed in SLA and post-polymerized in microwave ovens showed the greatest variations in their dimensions, for the occlusal splint resin, the OS-SLA-MW group (-4.29 ± 3.15)A showed a shrinkage of 40.2%. The resins for models (3.31 ± 0.66)A and temporary (-2.06 ± 1.52)A showed a shrinkage of 33% and 20.6%, respectively. Conclusions LCD printing with UV light postpolymerization was the most effective method for resins used in occlusal splints, dental models, and temporary restorations. SLA printing with UV postpolymerization showed the most significant dimensional changes, leading to shrinkage in occlusal splint resins, while model resins and temporary restorations expanded. Clinical relevance Resins for 3D printing should ideally be post-polymerized with UV light and printed using LCD technology, as this approach results in better mechanical properties and less dimensional change compared to microwave oven post-polymerization.
- 19 October 2024
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 28 (11) , 1-19
Influence of 3D printing system, postpolymerization and aging protocols on resin flexural strength and dimensional stability for printing occlusal splints, models and temporary restorations
Objectives Investigate the effect of different postpolymerization protocols, aging, and 3D printing systems on the flexural strength (σ), dimensional stability, and roughness of resins used to fabricate occlusal splints, dental models, and temporary restorations. Material and methods 180 bars (25 × 2 x 2 mm—ISO 4049) of each type of resin (T—Temporary/Cosmos Temp, Yller; OS—Occlusal splint/Cosmos Splint, Yller; MO – Models/ Cosmos Model, Yller) were printed and divided into 12 groups (n = 15) according to the factors: “Postpolymerization” (Ctr – Control; UV – Ultraviolet oven and MW – Microwave); “Printer” (SLA- stereolithography (Forms 2/Formslab); LCD- liquid crystal display (FlashForge Foto 6.0/FlashForge)) and “Aging” (TC – 10,000 thermocycling cycles and Without). Each bar was measured with a digital caliper at 11 points before and after postpolymerization to evaluate dimensional stability. The samples were subjected to the σ test (100Kgf;1 mm/min). Data was evaluated using Three- and Two-way ANOVA, and Tukey’s test (5%). Weibull analysis, Scanning Electron Microscopic and optical profilometry was performed. Results LCD printing system and UV oven postpolymerization exhibited the highest σ (P < .05). The groups printed in SLA and post-polymerized in microwave ovens showed the greatest variations in their dimensions, for the occlusal splint resin, the OS-SLA-MW group (-4.29 ± 3.15)A showed a shrinkage of 40.2%. The resins for models (3.31 ± 0.66)A and temporary (-2.06 ± 1.52)A showed a shrinkage of 33% and 20.6%, respectively. Conclusions LCD printing with UV light postpolymerization was the most effective method for resins used in occlusal splints, dental models, and temporary restorations. SLA printing with UV postpolymerization showed the most significant dimensional changes, leading to shrinkage in occlusal splint resins, while model resins and temporary restorations expanded. Clinical relevance Resins for 3D printing should ideally be post-polymerized with UV light and printed using LCD technology, as this approach results in better mechanical properties and less dimensional change compared to microwave oven post-polymerization.
- 6 September 2024
- Published by Springer Nature in Odontology
- Vol. 113 (2) , 619-633
Influence of build direction, post-polymerization time, and aging on the fracture resistance and marginal and internal discrepancies of three-dimensional printed provisional crowns
To evaluate the effect of build direction, post-polymerization time, and aging on the fracture resistance, failure mode, margin quality and Marginal (MD) and Internal Discrepancies (ID), and degree of conversion of tridimensional (3D) printed provisional crowns using the liquid crystal display technique (LCD). A left mandibular first molar was prepared and scanned. After, a full crown was designed (ExoCad) and exported to the LCD-printer software. One hundred and eighty crowns were printed at two build directions (30°, 90°) and post-polymerized for different periods (15, 30, 45 min). Half of the samples were aged (ST) in distilled water (37 °C/90 days). The marginal quality of the crowns was evaluated by the Schriwer method under a stereomicroscope (40x). The replica technique was used to measure the MD and ID and measured under a stereomicroscope (10x), through 20 reference points defined in 5 regions: Occlusal (O), Cusp (CP), Axial (AX), Chamfer (CH), and Finish Line (F). After, the crowns were cemented onto the respective dies using temporary cement and submitted to compression test (ISO150, 1 mm/min, 100 kgf).The failure mode was classified by Burke’s fracture mode. The degree of conversion was evaluated through Fourier Transform Infrared Spectroscopy. The data (μm) of MD and ID and fracture resistance (N) were subjected to ANOVA (3 factors) and Tukey’s test (5%); Weibull analysis was also performed for fracture resistance data (N). For MD, ID and fracture resistance ANOVA revealed that all factors (P < .001) were significant. For aged groups, the crowns printed at 30° showed lower MD (Tukey). The O_90_30 min (172.13A μm) and O_90_15 min (170.20A μm) groups showed the highest ID values. Higher resistance values were observed for the 30_45 min (844.30A N), 30_30 min (835.35A N), and 90_30 min (820.62A N) groups (Tukey). In the margin analysis, 98.6% of the crowns printed at 30° showed smooth margins without defects. The most prevalent fracture mode (41.7%) was Burke type 5. The degree of conversion (DC) increased with increasing post-polymerization time and aging. Printing provisional crowns at 30° provided lower crown MD and ID, as well as higher fracture resistance. A post-polymerization time of 30 min resulted in higher crown fracture resistance, while aging reduced the resistance of the crowns. Graphical abstract
- 6 September 2024
- Published by Springer Nature in Odontology
- Vol. 113 (2) , 619-633
Influence of build direction, post-polymerization time, and aging on the fracture resistance and marginal and internal discrepancies of three-dimensional printed provisional crowns
To evaluate the effect of build direction, post-polymerization time, and aging on the fracture resistance, failure mode, margin quality and Marginal (MD) and Internal Discrepancies (ID), and degree of conversion of tridimensional (3D) printed provisional crowns using the liquid crystal display technique (LCD). A left mandibular first molar was prepared and scanned. After, a full crown was designed (ExoCad) and exported to the LCD-printer software. One hundred and eighty crowns were printed at two build directions (30°, 90°) and post-polymerized for different periods (15, 30, 45 min). Half of the samples were aged (ST) in distilled water (37 °C/90 days). The marginal quality of the crowns was evaluated by the Schriwer method under a stereomicroscope (40x). The replica technique was used to measure the MD and ID and measured under a stereomicroscope (10x), through 20 reference points defined in 5 regions: Occlusal (O), Cusp (CP), Axial (AX), Chamfer (CH), and Finish Line (F). After, the crowns were cemented onto the respective dies using temporary cement and submitted to compression test (ISO150, 1 mm/min, 100 kgf).The failure mode was classified by Burke’s fracture mode. The degree of conversion was evaluated through Fourier Transform Infrared Spectroscopy. The data (μm) of MD and ID and fracture resistance (N) were subjected to ANOVA (3 factors) and Tukey’s test (5%); Weibull analysis was also performed for fracture resistance data (N). For MD, ID and fracture resistance ANOVA revealed that all factors (P < .001) were significant. For aged groups, the crowns printed at 30° showed lower MD (Tukey). The O_90_30 min (172.13A μm) and O_90_15 min (170.20A μm) groups showed the highest ID values. Higher resistance values were observed for the 30_45 min (844.30A N), 30_30 min (835.35A N), and 90_30 min (820.62A N) groups (Tukey). In the margin analysis, 98.6% of the crowns printed at 30° showed smooth margins without defects. The most prevalent fracture mode (41.7%) was Burke type 5. The degree of conversion (DC) increased with increasing post-polymerization time and aging. Printing provisional crowns at 30° provided lower crown MD and ID, as well as higher fracture resistance. A post-polymerization time of 30 min resulted in higher crown fracture resistance, while aging reduced the resistance of the crowns. Graphical abstract
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 35, e24-5581
Effect of ZrO2 paste, surface treatments, and storage on Weibull characteristics and resin bond strength to zirconia
The objective is to evaluate the effect of different surface treatments and storage on the shear strength of ultratranslucent zirconia. 36 blocks of ultra-translucent zirconia were fabricated (7x7x2mm) and sintered. Then, divided into 12 groups according to the “surface treatment” (C -Primer; Al -Sandblasting with Al2O3 + Primer; Si -Silicate + Primer; Gl -Glaze + HF + Primer; Z -Zirlink; Zp -Zirlink + Primer) and “storage” factors (ST-with 150 days/37º and without). After surface treatment, five cylinders (Ø=2mm; h=2.0mm) of resin cement (n=15) were constructed in each ceramic block; at the end, the shear strength test was performed (1mm/min, 50Kgf), and analysis of surface failures. 60 additional samples (2x2x2mm) were made for extras analysis (surface roughness, MEV, and EDS). Bond strength and surface roughness data were statistically evaluated by ANOVA (2 factors/1 factor), Tukey test (5%), and Weibull analysis, respectively. ANOVA (2-way) revealed that all factors were statistically significant for bond strength. The silicatization groups (SiST: 30.47AMPa; Si: 29.21AMPa) showed the highest bond strength values, regardless of storage (Tukey's test). While the groups treated with Zirlink (ZST: 2.76FMPa; Z: 5.27EFMPa) showed the lowest values, just similar to the GlST group (5.14EFMPa). The Weibull modulus (m) showed a statistical difference between groups (p=0.000). ANOVA (1 factor) revealed that the "surface treatment" factor (p=0.0000) was statistically significant for surface roughness. Therefore, the application of Zirlink and Glaze on pre-sintered zirconia did not promote efficient adhesion of the ultratranslucent zirconia to the resin cement, even when associated with a primer containing MDP.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 35, e24-5581
Open AccessEffect of ZrO2 paste, surface treatments, and storage on Weibull characteristics and resin bond strength to zirconia
The objective is to evaluate the effect of different surface treatments and storage on the shear strength of ultratranslucent zirconia. 36 blocks of ultra-translucent zirconia were fabricated (7x7x2mm) and sintered. Then, divided into 12 groups according to the “surface treatment” (C -Primer; Al -Sandblasting with Al2O3 + Primer; Si -Silicate + Primer; Gl -Glaze + HF + Primer; Z -Zirlink; Zp -Zirlink + Primer) and “storage” factors (ST-with 150 days/37º and without). After surface treatment, five cylinders (Ø=2mm; h=2.0mm) of resin cement (n=15) were constructed in each ceramic block; at the end, the shear strength test was performed (1mm/min, 50Kgf), and analysis of surface failures. 60 additional samples (2x2x2mm) were made for extras analysis (surface roughness, MEV, and EDS). Bond strength and surface roughness data were statistically evaluated by ANOVA (2 factors/1 factor), Tukey test (5%), and Weibull analysis, respectively. ANOVA (2-way) revealed that all factors were statistically significant for bond strength. The silicatization groups (SiST: 30.47AMPa; Si: 29.21AMPa) showed the highest bond strength values, regardless of storage (Tukey's test). While the groups treated with Zirlink (ZST: 2.76FMPa; Z: 5.27EFMPa) showed the lowest values, just similar to the GlST group (5.14EFMPa). The Weibull modulus (m) showed a statistical difference between groups (p=0.000). ANOVA (1 factor) revealed that the "surface treatment" factor (p=0.0000) was statistically significant for surface roughness. Therefore, the application of Zirlink and Glaze on pre-sintered zirconia did not promote efficient adhesion of the ultratranslucent zirconia to the resin cement, even when associated with a primer containing MDP.