LTLong To

Long To

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Long To has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    688. Incidence and Risk Factors for Prosthetic Valve Endocarditis Following TAVR: 2015-2019

    by Jamison Montes de Oca, Rachel Kenney, Janet F Wyman, Dee Dee Wang, Brian O'Neill, Marvin Eng, James Lee, Pedro F Villablanca, Long To

    Transcatheter aortic valve replacement (TAVR) is increasingly used for lower risk patients. Incidence of TAVR endocarditis ranges from 0.2% to 3.3%. The purpose of this study was to determine local incidence and risk factors of prosthetic valve infective endocarditis (PVIE) in a contemporary cohort. IRB approved retrospective, nested case-control study evaluated the 1-year incidence and risk factors for PVIE among TAVR recipients from 2015 to 2019. Inclusion: ≥ 18 years, TAVR procedure at Henry Ford Health System. Exclusion: repeat TAVR. PVIE cases were matched with controls who did not experience PVIE. PVIE defined as diagnosis documentation in the electronic medical record. Figure 1. Study Design 23/1266 patients were identified as cases corresponding to a 1-year incidence of 1.82%. The median time to PVIE was 127 days and 35% occurred within 60 days. The most frequently isolated organisms were streptococci (26%), MRSA (13%), and MSSA (13%). Baseline demographics and comorbidities for 23 PVIE cases and 161 controls are displayed in Table 1. Significant risk factors for PVIE in bivariate analysis included STS-PROM (Society of Thoracic Surgeons Predicted Risk of Mortality), median: 4.1 controls and 6.4 cases (p = 0.012). Age, BMI, and comorbidities were not significantly different. Diabetes was notably more frequent among cases (36% vs 48%, p = 0.274). Patients with PVIE had more post-op RBC transfusions (5% vs 21.7% p = 0.003), ECG changes (23% vs 43.5%, p = 0.035), heart block (15.5% vs 34.8%, p = 0.038), longer length of stay (2 days, range 1 to 4 vs 4 to 11, p = 0.004), and thirty-day readmission (10.6% vs 52.2%, p < 0.001). Results displayed in Table 2. Table 1. Patient Characteristics and Risk Factor Analysis Table 2. Additional Outcomes The results from this study give insight to the local incidence, microbiology, and risk of PVIE following TAVR. Future directions include a larger evaluation of modifiable risks such as diabetes management and examining the heart block patients who received permanent pacemaker implants. Rachel Kenney, PharmD, Medtronic, Inc. (Other Financial or Material Support, spouse is an employee and shareholder) Janet F. Wyman, DNP, CNS-BC, FACC, Edwards Lifesciences (Consultant) Dee Dee Wang, MD, Edwards LifeSciences (Consultant) Brian O'Neill, MD, Edwards Lifesciences (Consultant)

  • Incidence of Heparin-Induced Thrombocytopenia in Patients With Newly Implanted Mechanical Circulatory Support Devices

    by Long To, Dana Attar, Brittany Lines, Melissa McCarty, Hassan Nemeh, Ileana Lopez-Plaza, Zachary Smith, Victor Coba, Jona Lekura

    Background: Heparin exposure and device-related thrombocytopenia complicate the diagnosis of heparin-induced thrombocytopenia (HIT) in patients receiving mechanical circulatory support (MCS). To improve anticoagulation management for patients with newly implanted MCS devices, incidence of confirmed HIT needs to be further characterized. Objectives: The purpose of this study is to describe the incidence of HIT and clinical utility of the 4Ts score in patients with newly implanted MCS devices. Methods: This is a retrospective analysis of MCS patients receiving unfractionated heparin from 2014 to 2017. The primary end point was incidence of laboratory-confirmed HIT. Strong positive, likely positive, low probability, and negative HIT categories were established based on heparin-induced platelet antibody (HIPA) and serotonin release assay (SRA). Secondary end points include characterization of platelet trends, argatroban use, incidence of HIT among each of the MCS devices, and utility of 4Ts score. Results: A total of 342 patient encounters met inclusion criteria, of which 68 HIPA tests and 25 SRAs were ordered. The incidence of HIT was 0.88% (3/342) and 4.4% (3/68) in patients with suspected HIT. Of the 68 HIPA tests, 3 (4.4%) were considered strong positive and 3 of the 25 SRAs were positive. Median 4Ts score was 4 [2.5-4] and optical density 0.19 [0.11-0.54]. The positive predictive value for the 4Ts score was 0.15 (CI = 0.03-0.46) and negative predictive value, 0.93 (CI = 0.82-0.98). Conclusion and Relevance: HIT occurs infrequently with newly implanted MCS devices. The 4Ts score appears to have a high negative predictive value for ruling out HIT.


  • Anticoagulation of Percutaneous Ventricular Assist Device Using Argatroban-Based Purge Solution: A Case Series

    by Emily C. Blum, Carolyn R. Martz, Yelena Selektor, Hassan Nemeh, Zachary R. Smith, Long To

    Impella devices are percutaneously inserted ventricular assist devices which require a continuous purge solution that contains heparin to prevent pump thrombosis and device failure. We describe 2 patients with heparin-induced thrombocytopenia (HIT) supported with an Impella device utilizing an argatroban-based purge solution. Case 1 involved an 83-year-old female with biventricular failure which resulted in right ventricle Impella support. The purge solution was changed to include argatroban due to concern of device clotting in the setting of HIT. Case 2 involved a 55-year-old male with worsening cardiogenic shock which resulted in left ventricle Impella support. Due to decreased purge flow rates and concerns for clotting, argatroban was added to the purge solution. Both patients’ total argatroban regimens were monitored and adjusted by pharmacy, resulting in therapeutic anticoagulation without any major bleeding or thrombotic events. Subsequently, a protocol was designed and implemented. These case reports appear to demonstrate the safe and effective use of argatroban purge solutions for the necessary anticoagulation with an Impella device. Further studies are needed to confirm these results and determine the optimal dosing regimen.


  • 465

    by Zachary Smith, Long To, Hassan Nemeh