Anticoagulation of Percutaneous Ventricular Assist Device Using Argatroban-Based Purge Solution: A Case Series
Authors:
- 23 August 2017
- journal article
- case report
- Published by SAGE Publications in Journal of Pharmacy Practice
- Vol. 31 (5) , 514-518
Abstract
Impella devices are percutaneously inserted ventricular assist devices which require a continuous purge solution that contains heparin to prevent pump thrombosis and device failure. We describe 2 patients with heparin-induced thrombocytopenia (HIT) supported with an Impella device utilizing an argatroban-based purge solution. Case 1 involved an 83-year-old female with biventricular failure which resulted in right ventricle Impella support. The purge solution was changed to include argatroban due to concern of device clotting in the setting of HIT. Case 2 involved a 55-year-old male with worsening cardiogenic shock which resulted in left ventricle Impella support. Due to decreased purge flow rates and concerns for clotting, argatroban was added to the purge solution. Both patients’ total argatroban regimens were monitored and adjusted by pharmacy, resulting in therapeutic anticoagulation without any major bleeding or thrombotic events. Subsequently, a protocol was designed and implemented. These case reports appear to demonstrate the safe and effective use of argatroban purge solutions for the necessary anticoagulation with an Impella device. Further studies are needed to confirm these results and determine the optimal dosing regimen.Keywords
This publication has 9 references indexed in Scilit:
- Use of an argatroban-based purge solution in a percutaneous ventricular assist deviceAmerican Journal of Health-System Pharmacy, 2017
- Impella ventricular support in clinical practice: Collaborative viewpoint from a European expert user groupInternational Journal of Cardiology, 2015
- Management and outcome of patients supported with Impella 5.0 for refractory cardiogenic shockCritical Care, 2015
- Incidence and prognosis of vascular complications after percutaneous placement of left ventricular assist deviceJournal of Vascular Surgery, 2015
- The Impella Device for Acute Mechanical Circulatory Support in Patients in Cardiogenic ShockThe Annals of Thoracic Surgery, 2014
- Effective Anticoagulation for a Percutaneous Ventricular Assist Device Using a Heparin-Based Purge SolutionAnnals of Pharmacotherapy, 2013
- 2013 ACCF/AHA Guideline for the Management of Heart FailureJACC, 2013
- Recommendations for the Use of Mechanical Circulatory Support: Device Strategies and Patient SelectionCirculation, 2012
- Extended use of a percutaneous left-ventricular assist device without a heparin-based purge solutionAmerican Journal of Health-System Pharmacy, 2010