Anh Igarashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anh Igarashi has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Hirohito Yamada
International Research Institute of Disaster Science, Tohoku University, 468-1 Aramaki-Aza-Aoba, Aoba-ku, Sendai 980-8572, Japan
3 shared publications - Tatsuo Yoshinobu
Graduate School of Biomedical Engineering, Tohoku University, Sendai, Miyagi 980-8579, Japan
2 shared publications Yasuo Ohtera
Toyama Prefectural University, Imizu, Japan
2 shared publicationsChanghao Feng
1 shared publicationHirohito Yamada
Tohoku University, Sendai, Japan
1 shared publication- Jingxuan Wu
College of Electronic and Information Engineering, Southwest University, Chongqing, China
1 shared publication
Latest Publications
- Open Access
- 7 July 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 467
Synergistic Ag decoration and Mo doping in electrospun ZnFe₂O₄ nanofibers for highly sensitive n-butanol detection
- 7 July 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 467
Open AccessSynergistic Ag decoration and Mo doping in electrospun ZnFe₂O₄ nanofibers for highly sensitive n-butanol detection
- 1 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (8) , 1-4
Nanograting Microring Optical Resonators for Enhanced Refractive Index Sensitivity
This study explores the optical resonance characteristics of a Si nanograting ring resonator (NGRR), which incorporates periodic nanograting structures along the microring to facilitate diffraction and promote localized optical field at resonance. The design and fabrication of the NGRR, configured with 100 nm × 60 nm gratings on a 4 μm-radius ring, are presented. Experimental characterization, including the transmission spectrum observed in the bus waveguide and near-field scattering imaging, reveals distinct concentric optical modes in the NGRR at resonance, which differ notably from those in a conventional microring resonator. The NGRR demonstrates a significant enhancement in refractive index sensitivity, achieving 495 nm/RIU, approximately seven times greater than that of the conventional microring resonator. Additionally, the NGRR with nanograting in bus waveguide exhibits a Q factor of 5800 at resonance wavelength of 1565 nm. Simulations validate the experimental results, showing resonance peaks and mode profiles consistent with observations. These finding highlight the potential of NGRRs in achieving high sensitivity while maintaining reasonable Q factors, even when the ring radius is small.
- 1 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (8) , 1-4
Nanograting Microring Optical Resonators for Enhanced Refractive Index Sensitivity
This study explores the optical resonance characteristics of a Si nanograting ring resonator (NGRR), which incorporates periodic nanograting structures along the microring to facilitate diffraction and promote localized optical field at resonance. The design and fabrication of the NGRR, configured with 100 nm × 60 nm gratings on a 4 μm-radius ring, are presented. Experimental characterization, including the transmission spectrum observed in the bus waveguide and near-field scattering imaging, reveals distinct concentric optical modes in the NGRR at resonance, which differ notably from those in a conventional microring resonator. The NGRR demonstrates a significant enhancement in refractive index sensitivity, achieving 495 nm/RIU, approximately seven times greater than that of the conventional microring resonator. Additionally, the NGRR with nanograting in bus waveguide exhibits a Q factor of 5800 at resonance wavelength of 1565 nm. Simulations validate the experimental results, showing resonance peaks and mode profiles consistent with observations. These finding highlight the potential of NGRRs in achieving high sensitivity while maintaining reasonable Q factors, even when the ring radius is small.
- Open Access
Enhancement of Refractive Index Sensitivity Using Small Footprint S-Shaped Double-Spiral Resonators for Biosensing
We demonstrate an S-shaped double-spiral microresonator (DSR) for detecting small volumes of analytes, such as liquids or gases, penetrating a microfluidic channel. Optical-ring resonators have been applied as label-free and high-sensitivity biosensors by using an evanescent field for sensing the refractive index of analytes. Enlarging the ring resonator size is a solution for amplifying the interactions between the evanescent field and biomolecules to obtain a higher refractive index sensitivity of the attached analytes. However, it requires a large platform of a hundred square millimeters, and 99% of the cavity area would not involve evanescent field sensing. In this report, we demonstrate the novel design of a Si-based S-shaped double-spiral resonator on a silicon-on-insulator substrate for which the cavity size was 41.6 µm × 88.4 µm. The proposed resonator footprint was reduced by 680 times compared to a microring resonator with the same cavity area. The fabricated resonator exposed more sensitive optical characteristics for refractive index biosensing thanks to the enhanced contact interface by a long cavity length of DSR structures. High quality factors of 1.8 × 104 were demonstrated for 1.2 mm length DSR structures, which were more than two times higher than the quality factors of microring resonators. A bulk sensitivity of 1410 nm/RIU was calculated for detecting 1 µL IPA solutions inside a 200 µm wide microchannel by using the DSR cavity, which had more than a 10-fold higher sensitivity than the sensitivity of the microring resonators. A DSR device was also used for the detection of 100 ppm acetone gas inside a closed bottle.
Open AccessEnhancement of Refractive Index Sensitivity Using Small Footprint S-Shaped Double-Spiral Resonators for Biosensing
We demonstrate an S-shaped double-spiral microresonator (DSR) for detecting small volumes of analytes, such as liquids or gases, penetrating a microfluidic channel. Optical-ring resonators have been applied as label-free and high-sensitivity biosensors by using an evanescent field for sensing the refractive index of analytes. Enlarging the ring resonator size is a solution for amplifying the interactions between the evanescent field and biomolecules to obtain a higher refractive index sensitivity of the attached analytes. However, it requires a large platform of a hundred square millimeters, and 99% of the cavity area would not involve evanescent field sensing. In this report, we demonstrate the novel design of a Si-based S-shaped double-spiral resonator on a silicon-on-insulator substrate for which the cavity size was 41.6 µm × 88.4 µm. The proposed resonator footprint was reduced by 680 times compared to a microring resonator with the same cavity area. The fabricated resonator exposed more sensitive optical characteristics for refractive index biosensing thanks to the enhanced contact interface by a long cavity length of DSR structures. High quality factors of 1.8 × 104 were demonstrated for 1.2 mm length DSR structures, which were more than two times higher than the quality factors of microring resonators. A bulk sensitivity of 1410 nm/RIU was calculated for detecting 1 µL IPA solutions inside a 200 µm wide microchannel by using the DSR cavity, which had more than a 10-fold higher sensitivity than the sensitivity of the microring resonators. A DSR device was also used for the detection of 100 ppm acetone gas inside a closed bottle.
- 13 March 2023
- Published by Springer Nature in Optical Review
- Vol. 30 (2) , 238-245
Si-microring resonator with sidewall nanograting structures for high-Q resonance modes
- 13 March 2023
- Published by Springer Nature in Optical Review
- Vol. 30 (2) , 238-245
Si-microring resonator with sidewall nanograting structures for high-Q resonance modes
- Open Access
- 19 May 2021
- Published by MDPI AG in Engineering Proceedings
- Vol. 6 (1) , 39
Photonic Biosensor for Label-Free Detection Based on Photonic Nanostructures on Si-Waveguide Ring Resonator
A new structure of a micro-ring resonator for label-free biosensing is proposed. The structure includes sidewall-grating Si waveguide and periodical side-blocks that can enhance the light–matter interaction. From the electromagnetic simulations, the proposed structure exhibits a four-fold improvement in terms of sensitivity compared with the conventional structure. Moreover, the quality factor of the proposed structure is not degraded from that of the conventional structure. The improved sensitivity is promising for the detection of nanoparticles that can be applied to the environmental field and clinical diagnostics.
- 19 May 2021
- Published by MDPI AG in Engineering Proceedings
- Vol. 6 (1) , 39
Open AccessPhotonic Biosensor for Label-Free Detection Based on Photonic Nanostructures on Si-Waveguide Ring Resonator
A new structure of a micro-ring resonator for label-free biosensing is proposed. The structure includes sidewall-grating Si waveguide and periodical side-blocks that can enhance the light–matter interaction. From the electromagnetic simulations, the proposed structure exhibits a four-fold improvement in terms of sensitivity compared with the conventional structure. Moreover, the quality factor of the proposed structure is not degraded from that of the conventional structure. The improved sensitivity is promising for the detection of nanoparticles that can be applied to the environmental field and clinical diagnostics.