Brian Erickson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Brian Erickson has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
- John Dominic Medaglia
Applied Cognitive and Brain Sciences, Department of Psychological and Brain Sciences, Drexel University, Philadelphia, PA 19104
12 shared publications - Flavia Vitale
Department of Bioengineering University of Pennsylvania Philadelphia Pennsylvania USA
5 shared publications - Ryan Rich
Applied Cognitive and Brain Sciences, Department of Psychological and Brain Sciences, Drexel University, Philadelphia, PA 19104
5 shared publications - Benjamin L. Deck
Drexel Univ, Dept Psychol & Brain Sci, 3201 Chestnut St, Philadelphia, PA 19104 USA
4 shared publications - Brian Kim
Department of Applied Cognitive and Brain Sciences, Drexel University, Philadelphia, PA, 19104, USA
3 shared publications - Guadalupe Fernandez-Nuñez
Applied Cognitive and Brain Sciences, Department of Psychology, Drexel University, Philadelphia, PA 19104, United States of America
3 shared publications
Latest Publications
- Open Access
Brief Trains of Closed-loop TMS Induce Controllable Power in FM-theta Oscillations
Objective: Frontal-midline theta (FM-theta; 4–8 Hz) oscillations are thought to support cognition. Brief trains of transcranial magnetic stimulation (TMS) can probe these oscillations with high temporal precision but have rarely changed theta power. One possible reason is that prior studies ignored the instantaneous phase of the oscillation, which strongly shapes the cortical response to TMS. We tested whether brief TMS trains triggered at specific FM-theta phases in real time directionally modulate post-train FM-theta power. Approach: Six healthy adults received TMS over dorsomedial prefrontal cortex (Fz) with concurrent electroencephalography during a whole-report working memory task. A beamformer and real-time phase-estimation pipeline triggered four-pulse 6 Hz trains (110% of resting motor threshold) at FM-theta peaks (0°) or troughs (180°), randomized trial by trial. Post-train spectral power was decomposed into total, induced (non-phase-locked) and evoked (phase-locked) components. Main results: Trough-triggered trains transiently increased post-train FM-theta power relative to peak-triggered trains; task performance did not differ. Cluster-based permutation tests showed trough−peak differences in total (4.6–7.1 Hz) and induced (5.0–7.8 Hz) power ∼50–440 ms after the train, suggesting amplification of the oscillation . No evoked effect was detected. The total-power effect was robust at the subject level (Cohen’s dz = 1.32, p = 0.023). Within-train theta power did not differ between conditions, suggesting a cortical origin. Significance: To our knowledge, this is the first study to lock brief rhythmic TMS trains to the real-time phase of an ongoing oscillation, and to show phase-dependent modulation of FM-theta power after individual trains on timescales relevant to behavior. Open-loop brief-train protocols may have missed such effects by mixing facilitatory and suppressive phases. Phase-locked brief trains offer a precise tool for testing the causal role of oscillations in cognition.
Open AccessBrief Trains of Closed-loop TMS Induce Controllable Power in FM-theta Oscillations
Objective: Frontal-midline theta (FM-theta; 4–8 Hz) oscillations are thought to support cognition. Brief trains of transcranial magnetic stimulation (TMS) can probe these oscillations with high temporal precision but have rarely changed theta power. One possible reason is that prior studies ignored the instantaneous phase of the oscillation, which strongly shapes the cortical response to TMS. We tested whether brief TMS trains triggered at specific FM-theta phases in real time directionally modulate post-train FM-theta power. Approach: Six healthy adults received TMS over dorsomedial prefrontal cortex (Fz) with concurrent electroencephalography during a whole-report working memory task. A beamformer and real-time phase-estimation pipeline triggered four-pulse 6 Hz trains (110% of resting motor threshold) at FM-theta peaks (0°) or troughs (180°), randomized trial by trial. Post-train spectral power was decomposed into total, induced (non-phase-locked) and evoked (phase-locked) components. Main results: Trough-triggered trains transiently increased post-train FM-theta power relative to peak-triggered trains; task performance did not differ. Cluster-based permutation tests showed trough−peak differences in total (4.6–7.1 Hz) and induced (5.0–7.8 Hz) power ∼50–440 ms after the train, suggesting amplification of the oscillation . No evoked effect was detected. The total-power effect was robust at the subject level (Cohen’s dz = 1.32, p = 0.023). Within-train theta power did not differ between conditions, suggesting a cortical origin. Significance: To our knowledge, this is the first study to lock brief rhythmic TMS trains to the real-time phase of an ongoing oscillation, and to show phase-dependent modulation of FM-theta power after individual trains on timescales relevant to behavior. Open-loop brief-train protocols may have missed such effects by mixing facilitatory and suppressive phases. Phase-locked brief trains offer a precise tool for testing the causal role of oscillations in cognition.
- Open Access
- 15 February 2026
- Published by Wiley in Advanced Science
- Vol. 13 (21) , e11486
Advancing Dry Electroencephalography With Scalable, Soft, and Transcranial Magnetic Stimulation‐Compatible Ti 3 C 2 T x MXene Electrodes for Research and Clinical‐Grade Applications
Electroencephalography (EEG), essential for diagnosing and researching neurological disorders, utilizes gelled electrodes, which present limitations in safety, comfort, stability, and usability, particularly in long‐term applications. We introduce a novel dry EEG technology using soft, porous, low‐impedance, Ti 3 C 2 T x MXene electrodes. The 10 Hz impedance of these electrodes across scalp locations is 2.1 ± 1.8 kΩ, comparable to gelled Ag/AgCl electrodes and below clinical thresholds. Ti 3 C 2 T x electrodes maintain stable impedance over 4.5 h on agarose phantoms and retain structure after 50 cycles of 80% axial compression. These electrodes are suitable for simultaneous EEG and transcranial magnetic stimulation (TMS), exhibiting no significant displacement, heating, or unsafe charge densities under TMS fields. We benchmarked dry electrodes across recording scenarios and hair types against gelled electrodes. In full‐scalp steady‐state visual evoked potential (SSVEP) recordings, gelled and Ti 3 C 2 T x electrodes were highly correlated (R > 0.89). Clinical EEG with Ti 3 C 2 T x electrodes captured all features observed with gelled electrodes (R > 0.84) and was rated for clinical quality by neurologists. Furthermore, dry MXene EEG electrode recorded high‐quality EEG for over 4 h. In mobile EEG, Ti 3 C 2 T x electrodes did not induce signal distortions and enabled task‐specific feature detection with a comparable signal‐to‐noise ratio to gelled electrodes. These findings establish dry Ti 3 C 2 T x electrodes as an alternative to gel‐based systems, with broad potential in clinical diagnostics and research.
- 15 February 2026
- Published by Wiley in Advanced Science
- Vol. 13 (21) , e11486
Open AccessAdvancing Dry Electroencephalography With Scalable, Soft, and Transcranial Magnetic Stimulation‐Compatible Ti 3 C 2 T x MXene Electrodes for Research and Clinical‐Grade Applications
Electroencephalography (EEG), essential for diagnosing and researching neurological disorders, utilizes gelled electrodes, which present limitations in safety, comfort, stability, and usability, particularly in long‐term applications. We introduce a novel dry EEG technology using soft, porous, low‐impedance, Ti 3 C 2 T x MXene electrodes. The 10 Hz impedance of these electrodes across scalp locations is 2.1 ± 1.8 kΩ, comparable to gelled Ag/AgCl electrodes and below clinical thresholds. Ti 3 C 2 T x electrodes maintain stable impedance over 4.5 h on agarose phantoms and retain structure after 50 cycles of 80% axial compression. These electrodes are suitable for simultaneous EEG and transcranial magnetic stimulation (TMS), exhibiting no significant displacement, heating, or unsafe charge densities under TMS fields. We benchmarked dry electrodes across recording scenarios and hair types against gelled electrodes. In full‐scalp steady‐state visual evoked potential (SSVEP) recordings, gelled and Ti 3 C 2 T x electrodes were highly correlated (R > 0.89). Clinical EEG with Ti 3 C 2 T x electrodes captured all features observed with gelled electrodes (R > 0.84) and was rated for clinical quality by neurologists. Furthermore, dry MXene EEG electrode recorded high‐quality EEG for over 4 h. In mobile EEG, Ti 3 C 2 T x electrodes did not induce signal distortions and enabled task‐specific feature detection with a comparable signal‐to‐noise ratio to gelled electrodes. These findings establish dry Ti 3 C 2 T x electrodes as an alternative to gel‐based systems, with broad potential in clinical diagnostics and research.
- Open Access
- 19 July 2025
- Published by Elsevier in Clinical Neurophysiology
- Vol. 178, 2110943
TMS motor evoked potential input-output curves predict the neuroplasticity effects of continuous theta burst stimulation
- 19 July 2025
- Published by Elsevier in Clinical Neurophysiology
- Vol. 178, 2110943
Open AccessTMS motor evoked potential input-output curves predict the neuroplasticity effects of continuous theta burst stimulation
- Open Access
- 22 March 2025
- Published by Springer Nature in Journal of Cognitive Enhancement
- Vol. 9 (2) , 214-229
Evaluating Risk and Benefit Sensitivity for Cognitive Treatments
Ethical judgments require clinicians, researchers, research participants, and patients to weigh risks and benefits. Novel treatments for cognitive deficits are rapidly emerging, but little is known about how individual differences in risk and benefit sensitivity influence ethical judgments to administer treatments. The public plays important roles as citizens, taxpayers, and consumers of cognitive treatments, yet little is known about how they evaluate risks and benefits in ethical judgments. We examined the influence of risk and benefit sensitivity on the public’s choices about treating cognitive dysfunction. We administered surveys, cognitive measures, and an ethical judgment paradigm to 425 participants recruited via Amazon Mechanical Turk. Participants were asked to choose whether to recommend a hypothetical cognitive treatment with varying degrees of risks and benefits across seven different cognitive domains. We expected participants to be more risk-sensitive than benefit-sensitive, especially when evaluating treatments that influence cognitive functions central to personal identity such as mood, self-control, and long-term memory. Unexpectedly, participants were slightly more sensitive to benefits and showed inter-domain stability across cognitive dysfunctions. Our results suggest that risks and benefits influence whether the public might recommend cognitive treatments. The relatively higher weight placed on benefits could be explained by prominent theories of decision-making under risk. Overall, this study suggests that judgment tasks can be adapted to study psychological ethical choices about treatments for cognitive deficits. Further study of individual variation in risk and benefit sensitivity and their influence on real-world ethical choices about cognitive repair could inform frameworks to enhance optimal neuroethical decision-making.
- 22 March 2025
- Published by Springer Nature in Journal of Cognitive Enhancement
- Vol. 9 (2) , 214-229
Open AccessEvaluating Risk and Benefit Sensitivity for Cognitive Treatments
Ethical judgments require clinicians, researchers, research participants, and patients to weigh risks and benefits. Novel treatments for cognitive deficits are rapidly emerging, but little is known about how individual differences in risk and benefit sensitivity influence ethical judgments to administer treatments. The public plays important roles as citizens, taxpayers, and consumers of cognitive treatments, yet little is known about how they evaluate risks and benefits in ethical judgments. We examined the influence of risk and benefit sensitivity on the public’s choices about treating cognitive dysfunction. We administered surveys, cognitive measures, and an ethical judgment paradigm to 425 participants recruited via Amazon Mechanical Turk. Participants were asked to choose whether to recommend a hypothetical cognitive treatment with varying degrees of risks and benefits across seven different cognitive domains. We expected participants to be more risk-sensitive than benefit-sensitive, especially when evaluating treatments that influence cognitive functions central to personal identity such as mood, self-control, and long-term memory. Unexpectedly, participants were slightly more sensitive to benefits and showed inter-domain stability across cognitive dysfunctions. Our results suggest that risks and benefits influence whether the public might recommend cognitive treatments. The relatively higher weight placed on benefits could be explained by prominent theories of decision-making under risk. Overall, this study suggests that judgment tasks can be adapted to study psychological ethical choices about treatments for cognitive deficits. Further study of individual variation in risk and benefit sensitivity and their influence on real-world ethical choices about cognitive repair could inform frameworks to enhance optimal neuroethical decision-making.
- Open Access
- 1 October 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (5) , 056035
TMS-induced phase resets depend on TMS intensity and EEG phase
Objective. The phase of the electroencephalographic (EEG) signal predicts performance in motor, somatosensory, and cognitive functions. Studies suggest that brain phase resets align neural oscillations with external stimuli, or couple oscillations across frequency bands and brain regions. Transcranial Magnetic Stimulation (TMS) can cause phase resets noninvasively in the cortex, thus providing the potential to control phase-sensitive cognitive functions. However, the relationship between TMS parameters and phase resetting is not fully understood. This is especially true of TMS intensity, which may be crucial to enabling precise control over the amount of phase resetting that is induced. Additionally, TMS phase resetting may interact with the instantaneous phase of the brain. Understanding these relationships is crucial to the development of more powerful and controllable stimulation protocols. Approach. To test these relationships, we conducted a TMS-EEG study. We applied single-pulse TMS at varying degrees of stimulation intensity to the motor area in an open loop. Offline, we used an autoregressive algorithm to estimate the phase of the intrinsic µ-Alpha rhythm of the motor cortex at the moment each TMS pulse was delivered. Main results. We identified post-stimulation epochs where µ-Alpha phase resetting and N100 amplitude depend parametrically on TMS intensity and are significant versus peripheral auditory sham stimulation. We observed µ-Alpha phase inversion after stimulations near peaks but not troughs in the endogenous µ-Alpha rhythm. Significance. These data suggest that low-intensity TMS primarily resets existing oscillations, while at higher intensities TMS may activate previously silent neurons, but only when endogenous oscillations are near the peak phase. These data can guide future studies that seek to induce phase resetting, and point to a way to manipulate the phase resetting effect of TMS by varying only the timing of the pulse with respect to ongoing brain activity.
- 1 October 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (5) , 056035
Open AccessTMS-induced phase resets depend on TMS intensity and EEG phase
Objective. The phase of the electroencephalographic (EEG) signal predicts performance in motor, somatosensory, and cognitive functions. Studies suggest that brain phase resets align neural oscillations with external stimuli, or couple oscillations across frequency bands and brain regions. Transcranial Magnetic Stimulation (TMS) can cause phase resets noninvasively in the cortex, thus providing the potential to control phase-sensitive cognitive functions. However, the relationship between TMS parameters and phase resetting is not fully understood. This is especially true of TMS intensity, which may be crucial to enabling precise control over the amount of phase resetting that is induced. Additionally, TMS phase resetting may interact with the instantaneous phase of the brain. Understanding these relationships is crucial to the development of more powerful and controllable stimulation protocols. Approach. To test these relationships, we conducted a TMS-EEG study. We applied single-pulse TMS at varying degrees of stimulation intensity to the motor area in an open loop. Offline, we used an autoregressive algorithm to estimate the phase of the intrinsic µ-Alpha rhythm of the motor cortex at the moment each TMS pulse was delivered. Main results. We identified post-stimulation epochs where µ-Alpha phase resetting and N100 amplitude depend parametrically on TMS intensity and are significant versus peripheral auditory sham stimulation. We observed µ-Alpha phase inversion after stimulations near peaks but not troughs in the endogenous µ-Alpha rhythm. Significance. These data suggest that low-intensity TMS primarily resets existing oscillations, while at higher intensities TMS may activate previously silent neurons, but only when endogenous oscillations are near the peak phase. These data can guide future studies that seek to induce phase resetting, and point to a way to manipulate the phase resetting effect of TMS by varying only the timing of the pulse with respect to ongoing brain activity.
- Open Access
- 9 August 2024
- Published by Center for Open Science in PsyArXiv
Evaluating Risk and Benefit Sensitivity for Cognitive Treatments
Ethical judgments require clinicians, researchers, research participants, and patients to weigh risks and benefits. Novel treatments for cognitive deficits are rapidly emerging, but little is known about how individual differences in risk and benefit sensitivity influence ethical judgments to administer treatments. The public plays important roles as citizens, taxpayers, and consumers of cognitive treatments, yet little is known about how they evaluate risks and benefits in ethical judgments. We examined the influence of risk and benefit sensitivity on the public’s choices about treating cognitive dysfunction. We administered surveys, cognitive measures, and an ethical judgment paradigm to 425 participants recruited via Amazon Mechanical Turk. Participants were asked to choose whether to recommend a hypothetical cognitive treatment with varying degrees of risks and benefits across seven different cognitive domains. We expected participants to be more risk-sensitive than benefit-sensitive, especially when evaluating treatments that influence cognitive functions central to personal identity such as mood, self-control, and long-term memory. Unexpectedly, participants were slightly more sensitive to benefits and showed inter-domain stability across cognitive dysfunctions. Our results suggest that risks and benefits influence whether the public might recommend cognitive treatments. The relatively higher weight placed on benefits could be explained by prominent theories of decision-making under risk. Overall, this study suggests that judgment tasks can be adapted to study psychological ethical choices about treatments for cognitive deficits. Further study of individual variation in risk and benefit sensitivity and their influence on real-world ethical choices about cognitive repair could inform frameworks to enhance optimal neuroethical decision-making.
- 9 August 2024
- Published by Center for Open Science in PsyArXiv
Open AccessEvaluating Risk and Benefit Sensitivity for Cognitive Treatments
Ethical judgments require clinicians, researchers, research participants, and patients to weigh risks and benefits. Novel treatments for cognitive deficits are rapidly emerging, but little is known about how individual differences in risk and benefit sensitivity influence ethical judgments to administer treatments. The public plays important roles as citizens, taxpayers, and consumers of cognitive treatments, yet little is known about how they evaluate risks and benefits in ethical judgments. We examined the influence of risk and benefit sensitivity on the public’s choices about treating cognitive dysfunction. We administered surveys, cognitive measures, and an ethical judgment paradigm to 425 participants recruited via Amazon Mechanical Turk. Participants were asked to choose whether to recommend a hypothetical cognitive treatment with varying degrees of risks and benefits across seven different cognitive domains. We expected participants to be more risk-sensitive than benefit-sensitive, especially when evaluating treatments that influence cognitive functions central to personal identity such as mood, self-control, and long-term memory. Unexpectedly, participants were slightly more sensitive to benefits and showed inter-domain stability across cognitive dysfunctions. Our results suggest that risks and benefits influence whether the public might recommend cognitive treatments. The relatively higher weight placed on benefits could be explained by prominent theories of decision-making under risk. Overall, this study suggests that judgment tasks can be adapted to study psychological ethical choices about treatments for cognitive deficits. Further study of individual variation in risk and benefit sensitivity and their influence on real-world ethical choices about cognitive repair could inform frameworks to enhance optimal neuroethical decision-making.
- Open Access
- 12 January 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (1) , 016005
Evaluating and benchmarking the EEG signal quality of high-density, dry MXene-based electrode arrays against gelled Ag/AgCl electrodes
Objective. To evaluate the signal quality of dry MXene-based electrode arrays (also termed ‘MXtrodes’) for electroencephalographic (EEG) recordings where gelled Ag/AgCl electrodes are a standard. Approach. We placed 4 × 4 MXtrode arrays and gelled Ag/AgCl electrodes on different scalp locations. The scalp was cleaned with alcohol and rewetted with saline before application. We recorded from both electrode types simultaneously while participants performed a vigilance task. Main results. The root mean squared amplitude of MXtrodes was slightly higher than that of Ag/AgCl electrodes (.24–1.94 uV). Most MXtrode pairs had slightly lower broadband spectral coherence (.05 to .1 dB) and Delta- and Theta-band timeseries correlation (.05 to .1 units) compared to the Ag/AgCl pair (p < .001). However, the magnitude of correlation and coherence was high across both electrode types. Beta-band timeseries correlation and spectral coherence were higher between neighboring MXtrodes in the array (.81 to .84 units) than between any other pair (.70 to .75 units). This result suggests the close spacing of the nearest MXtrodes (3 mm) more densely sampled high spatial-frequency topographies. Event-related potentials were more similar between MXtrodes (ρ ⩾ .95) than equally spaced Ag/AgCl electrodes (ρ ⩽ .77, p < .001). Dry MXtrode impedance (x̄ = 5.15 KΩ cm2) was higher and more variable than gelled Ag/AgCl electrodes (x̄ = 1.21 KΩ cm2, p < .001). EEG was also recorded on the scalp across diverse hair types. Significance. Dry MXene-based electrodes record EEG at a quality comparable to conventional gelled Ag/AgCl while requiring minimal scalp preparation and no gel. MXtrodes can record independent signals at a spatial density four times higher than conventional electrodes, including through hair, thus opening novel opportunities for research and clinical applications that could benefit from dry and higher-density configurations.
- 12 January 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (1) , 016005
Open AccessEvaluating and benchmarking the EEG signal quality of high-density, dry MXene-based electrode arrays against gelled Ag/AgCl electrodes
Objective. To evaluate the signal quality of dry MXene-based electrode arrays (also termed ‘MXtrodes’) for electroencephalographic (EEG) recordings where gelled Ag/AgCl electrodes are a standard. Approach. We placed 4 × 4 MXtrode arrays and gelled Ag/AgCl electrodes on different scalp locations. The scalp was cleaned with alcohol and rewetted with saline before application. We recorded from both electrode types simultaneously while participants performed a vigilance task. Main results. The root mean squared amplitude of MXtrodes was slightly higher than that of Ag/AgCl electrodes (.24–1.94 uV). Most MXtrode pairs had slightly lower broadband spectral coherence (.05 to .1 dB) and Delta- and Theta-band timeseries correlation (.05 to .1 units) compared to the Ag/AgCl pair (p < .001). However, the magnitude of correlation and coherence was high across both electrode types. Beta-band timeseries correlation and spectral coherence were higher between neighboring MXtrodes in the array (.81 to .84 units) than between any other pair (.70 to .75 units). This result suggests the close spacing of the nearest MXtrodes (3 mm) more densely sampled high spatial-frequency topographies. Event-related potentials were more similar between MXtrodes (ρ ⩾ .95) than equally spaced Ag/AgCl electrodes (ρ ⩽ .77, p < .001). Dry MXtrode impedance (x̄ = 5.15 KΩ cm2) was higher and more variable than gelled Ag/AgCl electrodes (x̄ = 1.21 KΩ cm2, p < .001). EEG was also recorded on the scalp across diverse hair types. Significance. Dry MXene-based electrodes record EEG at a quality comparable to conventional gelled Ag/AgCl while requiring minimal scalp preparation and no gel. MXtrodes can record independent signals at a spatial density four times higher than conventional electrodes, including through hair, thus opening novel opportunities for research and clinical applications that could benefit from dry and higher-density configurations.
- Open Access
- 10 October 2023
- Published by Elsevier in NeuroImage
- Vol. 283, 120386
Individual-level functional connectivity predicts cognitive control efficiency
- 10 October 2023
- Published by Elsevier in NeuroImage
- Vol. 283, 120386
Open AccessIndividual-level functional connectivity predicts cognitive control efficiency
- 8 October 2023
- Published by Oxford University Press (OUP) in Archives of Clinical Neuropsychology
- Vol. 38 (7) , 1347-1348
A - 175 EEG Phase Can be Predicted with Similar Accuracy across Cognitive States after Accounting for Power and SNR
Electroencephalogram (EEG) phase can capture neural oscillation dynamics. Accordingly, EEG phase is a potential target for neurofeedback and brain-computer interfaces (BCIs). However, rigorous tests of the generalizability of real-time EEG phase are needed, requiring accurate phase estimates. We examined how cognitive states affect EEG phase prediction accuracy in the parieto-occipital alpha band. We identified datasets through public repositories. After preprocessing, we used the Educated Temporal Prediction Algorithm (ETP) to predict future peaks. We compared these predictions to the original signal, and defined accuracy from 0 to 100%. Our independent variable was cognitive state (eyes-open rest, eyes-closed rest, task), dependent variable was accuracy, and covariates were EEG instantaneous power and signal-to-noise ratio (SNR). We used a linear mixed-effects model, with random effects for dataset and individual. Across the 11 datasets, we had 543 participants and 1,641,074 predictions. There were no significant accuracy differences among the conditions (p < 1e-5), with a baseline accuracy of 59.07%. Power had an effect on accuracy, with a unit increase leading to a 13.1% increase in accuracy (p < 1e-5). SNR had an effect on accuracy, with an effect size of 0.46% (p < 1e-5), with a significant negative interaction with power with an effect size of −0.51% (p < 1e-5). Our results indicated that we could predict EEG phase accurately across cognitive conditions and datasets, with higher accuracy for high instantaneous band-power and SNR. Accordingly, real-time EEG phase experiments, closed-loop technologies, and BCIs should minimize external unwanted noise while targeting periods of high power, as opposed to manipulating experimental and cognitive conditions.
- 8 October 2023
- Published by Oxford University Press (OUP) in Archives of Clinical Neuropsychology
- Vol. 38 (7) , 1347-1348
A - 175 EEG Phase Can be Predicted with Similar Accuracy across Cognitive States after Accounting for Power and SNR
Electroencephalogram (EEG) phase can capture neural oscillation dynamics. Accordingly, EEG phase is a potential target for neurofeedback and brain-computer interfaces (BCIs). However, rigorous tests of the generalizability of real-time EEG phase are needed, requiring accurate phase estimates. We examined how cognitive states affect EEG phase prediction accuracy in the parieto-occipital alpha band. We identified datasets through public repositories. After preprocessing, we used the Educated Temporal Prediction Algorithm (ETP) to predict future peaks. We compared these predictions to the original signal, and defined accuracy from 0 to 100%. Our independent variable was cognitive state (eyes-open rest, eyes-closed rest, task), dependent variable was accuracy, and covariates were EEG instantaneous power and signal-to-noise ratio (SNR). We used a linear mixed-effects model, with random effects for dataset and individual. Across the 11 datasets, we had 543 participants and 1,641,074 predictions. There were no significant accuracy differences among the conditions (p < 1e-5), with a baseline accuracy of 59.07%. Power had an effect on accuracy, with a unit increase leading to a 13.1% increase in accuracy (p < 1e-5). SNR had an effect on accuracy, with an effect size of 0.46% (p < 1e-5), with a significant negative interaction with power with an effect size of −0.51% (p < 1e-5). Our results indicated that we could predict EEG phase accurately across cognitive conditions and datasets, with higher accuracy for high instantaneous band-power and SNR. Accordingly, real-time EEG phase experiments, closed-loop technologies, and BCIs should minimize external unwanted noise while targeting periods of high power, as opposed to manipulating experimental and cognitive conditions.
- 24 August 2022
- Published by Drexel University Libraries
The Effect of Rest and Task States on EEG Phase Prediction Accuracy
Single-trial analyses of EEG signals have demonstrated a relationship between the instantaneous phase and cortical excitability (Bergmann et al., 2012; Massimini et al., 2003; Thies et al., 2018), sensory thresholding (Ai & Ro, 2014), and intracranial electrical activity (Haegens et al., 2011; Miller et al., 2012). Considering the relationships associated with EEG phase, accurately predicting phase in real-time has multiple benefits. The ability to accurately target phase will give researchers greater power in future phase-behavior experiments, potentially revealing how phasic processes are implemented and maintained in neuronal populations. Accurate phase prediction can help neuromodulation techniques in a closed-loop fashion, particularly non-invasive brain stimulation (Zrenner et al., 2018), which may operate through phase-resetting mechanisms (Kawasaki et al., 2014). Brain-computer interfaces implementing phase measures (Brunner et al., 2006; Hsu, 2015) will also benefit from increased real-time phase estimation. The current cognitive faculty (e.g., attention) an individual is engaged in affects ongoing oscillations (Klimesch, 1999). These changes are manifested through altered signal-to-noise ratios in the oscillations (Pijn et al., 1991). Although there are many ways to characterize an individual's cognitive state, a basic distinction can be made between rest (eyes-open and eyes-closed) and task states. Neuroimaging shows differences among these states, with default mode network activation in resting-state functional connectivity studies, and alpha-band power increase during rest (Raichle, 2015; Compston, 2010). Although these states exhibit large changes in neuroimaging, how they affect EEG phase prediction accuracy is currently unknown. The current project compared EEG phase prediction accuracy in the occipital alpha band between rest and task. Parieto-occipital alpha waves are an ideal signal to display these distinctions as they exhibit the highest power of all EEG frequency bands (Lozano-Soldevilla, 2018). The study used data from multiple online dataset repositories and direct solicitation from researchers. The datasets consisted of rest and task datasets. The task datasets employed a variety of cognitive domains (vigilance, executive attention, decision-making, working memory). For prediction, we used the Educated Temporal Prediction Algorithm, a novel, quick, accurate, and parameter-free phase detection algorithm, on each of these datasets to predict phase angles (Shirinpour et al., 2020). We then used a linear mixed effects model to identify the effect of rest and task on EEG phase prediction accuracy. Our results indicated that the eyes-closed resting state gives the highest accuracy (76.4%, 95% CI [75.0%, 77.9%]), followed by task states (74.7%, 95% CI [72.7%, 76.7%]) and then eyes-open resting state (72.81%, 95% CI [72.8%, 73.1%]). EEG signal power and signal-to-noise ratio (SNR) are significant covariates that also increase accuracy. As such, experiments involving real-time phase prediction may benefit from utilizing periods of high power and SNR in an eyes-closed resting condition.
- 24 August 2022
- Published by Drexel University Libraries
The Effect of Rest and Task States on EEG Phase Prediction Accuracy
Single-trial analyses of EEG signals have demonstrated a relationship between the instantaneous phase and cortical excitability (Bergmann et al., 2012; Massimini et al., 2003; Thies et al., 2018), sensory thresholding (Ai & Ro, 2014), and intracranial electrical activity (Haegens et al., 2011; Miller et al., 2012). Considering the relationships associated with EEG phase, accurately predicting phase in real-time has multiple benefits. The ability to accurately target phase will give researchers greater power in future phase-behavior experiments, potentially revealing how phasic processes are implemented and maintained in neuronal populations. Accurate phase prediction can help neuromodulation techniques in a closed-loop fashion, particularly non-invasive brain stimulation (Zrenner et al., 2018), which may operate through phase-resetting mechanisms (Kawasaki et al., 2014). Brain-computer interfaces implementing phase measures (Brunner et al., 2006; Hsu, 2015) will also benefit from increased real-time phase estimation. The current cognitive faculty (e.g., attention) an individual is engaged in affects ongoing oscillations (Klimesch, 1999). These changes are manifested through altered signal-to-noise ratios in the oscillations (Pijn et al., 1991). Although there are many ways to characterize an individual's cognitive state, a basic distinction can be made between rest (eyes-open and eyes-closed) and task states. Neuroimaging shows differences among these states, with default mode network activation in resting-state functional connectivity studies, and alpha-band power increase during rest (Raichle, 2015; Compston, 2010). Although these states exhibit large changes in neuroimaging, how they affect EEG phase prediction accuracy is currently unknown. The current project compared EEG phase prediction accuracy in the occipital alpha band between rest and task. Parieto-occipital alpha waves are an ideal signal to display these distinctions as they exhibit the highest power of all EEG frequency bands (Lozano-Soldevilla, 2018). The study used data from multiple online dataset repositories and direct solicitation from researchers. The datasets consisted of rest and task datasets. The task datasets employed a variety of cognitive domains (vigilance, executive attention, decision-making, working memory). For prediction, we used the Educated Temporal Prediction Algorithm, a novel, quick, accurate, and parameter-free phase detection algorithm, on each of these datasets to predict phase angles (Shirinpour et al., 2020). We then used a linear mixed effects model to identify the effect of rest and task on EEG phase prediction accuracy. Our results indicated that the eyes-closed resting state gives the highest accuracy (76.4%, 95% CI [75.0%, 77.9%]), followed by task states (74.7%, 95% CI [72.7%, 76.7%]) and then eyes-open resting state (72.81%, 95% CI [72.8%, 73.1%]). EEG signal power and signal-to-noise ratio (SNR) are significant covariates that also increase accuracy. As such, experiments involving real-time phase prediction may benefit from utilizing periods of high power and SNR in an eyes-closed resting condition.