Brian Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Brian Kim has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- John Dominic Medaglia
Applied Cognitive and Brain Sciences, Department of Psychological and Brain Sciences, Drexel University, Philadelphia, PA 19104
5 shared publications - Brian Erickson
Applied Cognitive and Brain Sciences, Department of Psychological and Brain Sciences, Drexel University, Philadelphia, PA 19104
3 shared publications - Flavia Vitale
Department of Bioengineering University of Pennsylvania Philadelphia Pennsylvania USA
3 shared publications - Guadalupe Fernandez-Nuñez
Applied Cognitive and Brain Sciences, Department of Psychology, Drexel University, Philadelphia, PA 19104, United States of America
3 shared publications - Ryan Rich
Applied Cognitive and Brain Sciences, Department of Psychological and Brain Sciences, Drexel University, Philadelphia, PA 19104
3 shared publications - Georgios Mentzelopoulos
Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104, United States of America
2 shared publications
Latest Publications
- Open Access
- 25 June 2026
- Published by MIT Press in Imaging Neuroscience
- Vol. 4
Frontoparietal Control-Default Mode Connectivity Predicts TMS Effects on Cognitive Control
Transcranial Magnetic Stimulation (TMS) is a promising tool to probe and enhance cognitive control, yet effects are often inconsistent across individuals. These inconsistencies may arise from individual differences in Lateral Frontoparietal (Control) Network (L-FPN) and Medial Frontoparietal (Default) Network (M-FPN) interactions, essential for suppressing internal distraction and facilitating cognitive control. We tested whether baseline connectivity between the L-FPN and M-FPN moderates TMS outcomes in cognitive control tasks. We used the generalized drift rate as a task-general behavioral index of cognitive control, as it overcomes the reliability and interpretability limitations of standard difference measures. Participants completed inhibition (Stroop), working memory (n-back), and flexibility (Navon) tasks before and after intermittent theta-burst stimulation (iTBS) to the L-FPN, dorsal frontoparietal (attention) network (D-FPN), or cranial vertex. Stimulation targets were defined using individualized resting-state parcellations to maximize precision. We found that baseline connectivity moderated stimulation outcomes: individuals with more integrated L-FPN/M-FPN networks benefited most from L-FPN stimulation, whereas those with more segregated networks showed greater improvements from D-FPN stimulation. Notably, stimulation of a single site did not uniformly enhance performance, underscoring the importance of individual network profiles. These findings highlight L-FPN/M-FPN interactions as a basis for individualized TMS interventions and the utility of combining precise network mapping with robust behavioral modeling to optimize neuromodulation interventions.
- 25 June 2026
- Published by MIT Press in Imaging Neuroscience
- Vol. 4
Open AccessFrontoparietal Control-Default Mode Connectivity Predicts TMS Effects on Cognitive Control
Transcranial Magnetic Stimulation (TMS) is a promising tool to probe and enhance cognitive control, yet effects are often inconsistent across individuals. These inconsistencies may arise from individual differences in Lateral Frontoparietal (Control) Network (L-FPN) and Medial Frontoparietal (Default) Network (M-FPN) interactions, essential for suppressing internal distraction and facilitating cognitive control. We tested whether baseline connectivity between the L-FPN and M-FPN moderates TMS outcomes in cognitive control tasks. We used the generalized drift rate as a task-general behavioral index of cognitive control, as it overcomes the reliability and interpretability limitations of standard difference measures. Participants completed inhibition (Stroop), working memory (n-back), and flexibility (Navon) tasks before and after intermittent theta-burst stimulation (iTBS) to the L-FPN, dorsal frontoparietal (attention) network (D-FPN), or cranial vertex. Stimulation targets were defined using individualized resting-state parcellations to maximize precision. We found that baseline connectivity moderated stimulation outcomes: individuals with more integrated L-FPN/M-FPN networks benefited most from L-FPN stimulation, whereas those with more segregated networks showed greater improvements from D-FPN stimulation. Notably, stimulation of a single site did not uniformly enhance performance, underscoring the importance of individual network profiles. These findings highlight L-FPN/M-FPN interactions as a basis for individualized TMS interventions and the utility of combining precise network mapping with robust behavioral modeling to optimize neuromodulation interventions.
- Open Access
- 12 January 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (1) , 016005
Evaluating and benchmarking the EEG signal quality of high-density, dry MXene-based electrode arrays against gelled Ag/AgCl electrodes
Objective. To evaluate the signal quality of dry MXene-based electrode arrays (also termed ‘MXtrodes’) for electroencephalographic (EEG) recordings where gelled Ag/AgCl electrodes are a standard. Approach. We placed 4 × 4 MXtrode arrays and gelled Ag/AgCl electrodes on different scalp locations. The scalp was cleaned with alcohol and rewetted with saline before application. We recorded from both electrode types simultaneously while participants performed a vigilance task. Main results. The root mean squared amplitude of MXtrodes was slightly higher than that of Ag/AgCl electrodes (.24–1.94 uV). Most MXtrode pairs had slightly lower broadband spectral coherence (.05 to .1 dB) and Delta- and Theta-band timeseries correlation (.05 to .1 units) compared to the Ag/AgCl pair (p < .001). However, the magnitude of correlation and coherence was high across both electrode types. Beta-band timeseries correlation and spectral coherence were higher between neighboring MXtrodes in the array (.81 to .84 units) than between any other pair (.70 to .75 units). This result suggests the close spacing of the nearest MXtrodes (3 mm) more densely sampled high spatial-frequency topographies. Event-related potentials were more similar between MXtrodes (ρ ⩾ .95) than equally spaced Ag/AgCl electrodes (ρ ⩽ .77, p < .001). Dry MXtrode impedance (x̄ = 5.15 KΩ cm2) was higher and more variable than gelled Ag/AgCl electrodes (x̄ = 1.21 KΩ cm2, p < .001). EEG was also recorded on the scalp across diverse hair types. Significance. Dry MXene-based electrodes record EEG at a quality comparable to conventional gelled Ag/AgCl while requiring minimal scalp preparation and no gel. MXtrodes can record independent signals at a spatial density four times higher than conventional electrodes, including through hair, thus opening novel opportunities for research and clinical applications that could benefit from dry and higher-density configurations.
- 12 January 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (1) , 016005
Open AccessEvaluating and benchmarking the EEG signal quality of high-density, dry MXene-based electrode arrays against gelled Ag/AgCl electrodes
Objective. To evaluate the signal quality of dry MXene-based electrode arrays (also termed ‘MXtrodes’) for electroencephalographic (EEG) recordings where gelled Ag/AgCl electrodes are a standard. Approach. We placed 4 × 4 MXtrode arrays and gelled Ag/AgCl electrodes on different scalp locations. The scalp was cleaned with alcohol and rewetted with saline before application. We recorded from both electrode types simultaneously while participants performed a vigilance task. Main results. The root mean squared amplitude of MXtrodes was slightly higher than that of Ag/AgCl electrodes (.24–1.94 uV). Most MXtrode pairs had slightly lower broadband spectral coherence (.05 to .1 dB) and Delta- and Theta-band timeseries correlation (.05 to .1 units) compared to the Ag/AgCl pair (p < .001). However, the magnitude of correlation and coherence was high across both electrode types. Beta-band timeseries correlation and spectral coherence were higher between neighboring MXtrodes in the array (.81 to .84 units) than between any other pair (.70 to .75 units). This result suggests the close spacing of the nearest MXtrodes (3 mm) more densely sampled high spatial-frequency topographies. Event-related potentials were more similar between MXtrodes (ρ ⩾ .95) than equally spaced Ag/AgCl electrodes (ρ ⩽ .77, p < .001). Dry MXtrode impedance (x̄ = 5.15 KΩ cm2) was higher and more variable than gelled Ag/AgCl electrodes (x̄ = 1.21 KΩ cm2, p < .001). EEG was also recorded on the scalp across diverse hair types. Significance. Dry MXene-based electrodes record EEG at a quality comparable to conventional gelled Ag/AgCl while requiring minimal scalp preparation and no gel. MXtrodes can record independent signals at a spatial density four times higher than conventional electrodes, including through hair, thus opening novel opportunities for research and clinical applications that could benefit from dry and higher-density configurations.
- 8 October 2023
- Published by Oxford University Press (OUP) in Archives of Clinical Neuropsychology
- Vol. 38 (7) , 1347-1348
A - 175 EEG Phase Can be Predicted with Similar Accuracy across Cognitive States after Accounting for Power and SNR
Electroencephalogram (EEG) phase can capture neural oscillation dynamics. Accordingly, EEG phase is a potential target for neurofeedback and brain-computer interfaces (BCIs). However, rigorous tests of the generalizability of real-time EEG phase are needed, requiring accurate phase estimates. We examined how cognitive states affect EEG phase prediction accuracy in the parieto-occipital alpha band. We identified datasets through public repositories. After preprocessing, we used the Educated Temporal Prediction Algorithm (ETP) to predict future peaks. We compared these predictions to the original signal, and defined accuracy from 0 to 100%. Our independent variable was cognitive state (eyes-open rest, eyes-closed rest, task), dependent variable was accuracy, and covariates were EEG instantaneous power and signal-to-noise ratio (SNR). We used a linear mixed-effects model, with random effects for dataset and individual. Across the 11 datasets, we had 543 participants and 1,641,074 predictions. There were no significant accuracy differences among the conditions (p < 1e-5), with a baseline accuracy of 59.07%. Power had an effect on accuracy, with a unit increase leading to a 13.1% increase in accuracy (p < 1e-5). SNR had an effect on accuracy, with an effect size of 0.46% (p < 1e-5), with a significant negative interaction with power with an effect size of −0.51% (p < 1e-5). Our results indicated that we could predict EEG phase accurately across cognitive conditions and datasets, with higher accuracy for high instantaneous band-power and SNR. Accordingly, real-time EEG phase experiments, closed-loop technologies, and BCIs should minimize external unwanted noise while targeting periods of high power, as opposed to manipulating experimental and cognitive conditions.
- 8 October 2023
- Published by Oxford University Press (OUP) in Archives of Clinical Neuropsychology
- Vol. 38 (7) , 1347-1348
A - 175 EEG Phase Can be Predicted with Similar Accuracy across Cognitive States after Accounting for Power and SNR
Electroencephalogram (EEG) phase can capture neural oscillation dynamics. Accordingly, EEG phase is a potential target for neurofeedback and brain-computer interfaces (BCIs). However, rigorous tests of the generalizability of real-time EEG phase are needed, requiring accurate phase estimates. We examined how cognitive states affect EEG phase prediction accuracy in the parieto-occipital alpha band. We identified datasets through public repositories. After preprocessing, we used the Educated Temporal Prediction Algorithm (ETP) to predict future peaks. We compared these predictions to the original signal, and defined accuracy from 0 to 100%. Our independent variable was cognitive state (eyes-open rest, eyes-closed rest, task), dependent variable was accuracy, and covariates were EEG instantaneous power and signal-to-noise ratio (SNR). We used a linear mixed-effects model, with random effects for dataset and individual. Across the 11 datasets, we had 543 participants and 1,641,074 predictions. There were no significant accuracy differences among the conditions (p < 1e-5), with a baseline accuracy of 59.07%. Power had an effect on accuracy, with a unit increase leading to a 13.1% increase in accuracy (p < 1e-5). SNR had an effect on accuracy, with an effect size of 0.46% (p < 1e-5), with a significant negative interaction with power with an effect size of −0.51% (p < 1e-5). Our results indicated that we could predict EEG phase accurately across cognitive conditions and datasets, with higher accuracy for high instantaneous band-power and SNR. Accordingly, real-time EEG phase experiments, closed-loop technologies, and BCIs should minimize external unwanted noise while targeting periods of high power, as opposed to manipulating experimental and cognitive conditions.
- Open Access
- 9 August 2023
- Published by Society for Neuroscience in eneuro
- Vol. 10 (9)
EEG Phase Can Be Predicted with Similar Accuracy across Cognitive States after Accounting for Power and Signal-to-Noise Ratio
EEG phase is increasingly used in cognitive neuroscience, brain–computer interfaces, and closed-loop stimulation devices. However, it is unknown how accurate EEG phase prediction is across cognitive states. We determined the EEG phase prediction accuracy of parieto-occipital alpha waves across rest and task states in 484 participants over 11 public datasets. We were able to track EEG phase accurately across various cognitive conditions and datasets, especially during periods of high instantaneous alpha power and signal-to-noise ratio (SNR). Although resting states generally have higher accuracies than task states, absolute accuracy differences were small, with most of these differences attributable to EEG power and SNR. These results suggest that experiments and technologies using EEG phase should focus more on minimizing external noise and waiting for periods of high power rather than inducing a particular cognitive state.
- 9 August 2023
- Published by Society for Neuroscience in eneuro
- Vol. 10 (9)
Open AccessEEG Phase Can Be Predicted with Similar Accuracy across Cognitive States after Accounting for Power and Signal-to-Noise Ratio
EEG phase is increasingly used in cognitive neuroscience, brain–computer interfaces, and closed-loop stimulation devices. However, it is unknown how accurate EEG phase prediction is across cognitive states. We determined the EEG phase prediction accuracy of parieto-occipital alpha waves across rest and task states in 484 participants over 11 public datasets. We were able to track EEG phase accurately across various cognitive conditions and datasets, especially during periods of high instantaneous alpha power and signal-to-noise ratio (SNR). Although resting states generally have higher accuracies than task states, absolute accuracy differences were small, with most of these differences attributable to EEG power and SNR. These results suggest that experiments and technologies using EEG phase should focus more on minimizing external noise and waiting for periods of high power rather than inducing a particular cognitive state.
- 24 August 2022
- Published by Drexel University Libraries
The Effect of Rest and Task States on EEG Phase Prediction Accuracy
Single-trial analyses of EEG signals have demonstrated a relationship between the instantaneous phase and cortical excitability (Bergmann et al., 2012; Massimini et al., 2003; Thies et al., 2018), sensory thresholding (Ai & Ro, 2014), and intracranial electrical activity (Haegens et al., 2011; Miller et al., 2012). Considering the relationships associated with EEG phase, accurately predicting phase in real-time has multiple benefits. The ability to accurately target phase will give researchers greater power in future phase-behavior experiments, potentially revealing how phasic processes are implemented and maintained in neuronal populations. Accurate phase prediction can help neuromodulation techniques in a closed-loop fashion, particularly non-invasive brain stimulation (Zrenner et al., 2018), which may operate through phase-resetting mechanisms (Kawasaki et al., 2014). Brain-computer interfaces implementing phase measures (Brunner et al., 2006; Hsu, 2015) will also benefit from increased real-time phase estimation. The current cognitive faculty (e.g., attention) an individual is engaged in affects ongoing oscillations (Klimesch, 1999). These changes are manifested through altered signal-to-noise ratios in the oscillations (Pijn et al., 1991). Although there are many ways to characterize an individual's cognitive state, a basic distinction can be made between rest (eyes-open and eyes-closed) and task states. Neuroimaging shows differences among these states, with default mode network activation in resting-state functional connectivity studies, and alpha-band power increase during rest (Raichle, 2015; Compston, 2010). Although these states exhibit large changes in neuroimaging, how they affect EEG phase prediction accuracy is currently unknown. The current project compared EEG phase prediction accuracy in the occipital alpha band between rest and task. Parieto-occipital alpha waves are an ideal signal to display these distinctions as they exhibit the highest power of all EEG frequency bands (Lozano-Soldevilla, 2018). The study used data from multiple online dataset repositories and direct solicitation from researchers. The datasets consisted of rest and task datasets. The task datasets employed a variety of cognitive domains (vigilance, executive attention, decision-making, working memory). For prediction, we used the Educated Temporal Prediction Algorithm, a novel, quick, accurate, and parameter-free phase detection algorithm, on each of these datasets to predict phase angles (Shirinpour et al., 2020). We then used a linear mixed effects model to identify the effect of rest and task on EEG phase prediction accuracy. Our results indicated that the eyes-closed resting state gives the highest accuracy (76.4%, 95% CI [75.0%, 77.9%]), followed by task states (74.7%, 95% CI [72.7%, 76.7%]) and then eyes-open resting state (72.81%, 95% CI [72.8%, 73.1%]). EEG signal power and signal-to-noise ratio (SNR) are significant covariates that also increase accuracy. As such, experiments involving real-time phase prediction may benefit from utilizing periods of high power and SNR in an eyes-closed resting condition.
- 24 August 2022
- Published by Drexel University Libraries
The Effect of Rest and Task States on EEG Phase Prediction Accuracy
Single-trial analyses of EEG signals have demonstrated a relationship between the instantaneous phase and cortical excitability (Bergmann et al., 2012; Massimini et al., 2003; Thies et al., 2018), sensory thresholding (Ai & Ro, 2014), and intracranial electrical activity (Haegens et al., 2011; Miller et al., 2012). Considering the relationships associated with EEG phase, accurately predicting phase in real-time has multiple benefits. The ability to accurately target phase will give researchers greater power in future phase-behavior experiments, potentially revealing how phasic processes are implemented and maintained in neuronal populations. Accurate phase prediction can help neuromodulation techniques in a closed-loop fashion, particularly non-invasive brain stimulation (Zrenner et al., 2018), which may operate through phase-resetting mechanisms (Kawasaki et al., 2014). Brain-computer interfaces implementing phase measures (Brunner et al., 2006; Hsu, 2015) will also benefit from increased real-time phase estimation. The current cognitive faculty (e.g., attention) an individual is engaged in affects ongoing oscillations (Klimesch, 1999). These changes are manifested through altered signal-to-noise ratios in the oscillations (Pijn et al., 1991). Although there are many ways to characterize an individual's cognitive state, a basic distinction can be made between rest (eyes-open and eyes-closed) and task states. Neuroimaging shows differences among these states, with default mode network activation in resting-state functional connectivity studies, and alpha-band power increase during rest (Raichle, 2015; Compston, 2010). Although these states exhibit large changes in neuroimaging, how they affect EEG phase prediction accuracy is currently unknown. The current project compared EEG phase prediction accuracy in the occipital alpha band between rest and task. Parieto-occipital alpha waves are an ideal signal to display these distinctions as they exhibit the highest power of all EEG frequency bands (Lozano-Soldevilla, 2018). The study used data from multiple online dataset repositories and direct solicitation from researchers. The datasets consisted of rest and task datasets. The task datasets employed a variety of cognitive domains (vigilance, executive attention, decision-making, working memory). For prediction, we used the Educated Temporal Prediction Algorithm, a novel, quick, accurate, and parameter-free phase detection algorithm, on each of these datasets to predict phase angles (Shirinpour et al., 2020). We then used a linear mixed effects model to identify the effect of rest and task on EEG phase prediction accuracy. Our results indicated that the eyes-closed resting state gives the highest accuracy (76.4%, 95% CI [75.0%, 77.9%]), followed by task states (74.7%, 95% CI [72.7%, 76.7%]) and then eyes-open resting state (72.81%, 95% CI [72.8%, 73.1%]). EEG signal power and signal-to-noise ratio (SNR) are significant covariates that also increase accuracy. As such, experiments involving real-time phase prediction may benefit from utilizing periods of high power and SNR in an eyes-closed resting condition.
- Open Access
- 4 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (3) , 601-613
Online Artifact Cancelation in Same-Electrode Neural Stimulation and Recording Using a Combined Hardware and Software Architecture
Advancing studies of neural network dynamics and developments of closed-loop neural interfaces requires the ability to simultaneously stimulate and record the neural cells. Recording adjacent to or at the stimulation site produces artifact signals that are orders of magnitude larger than the neural responses of interest. These signals often saturate the recording amplifier causing distortion or loss of short-latency evoked responses. This paper proposes a method to cancel the artifact in simultaneous neural recording and stimulation on the same electrode. By combining a novel hardware architecture with concurrent software processing, the design achieves neural signal recovery in a wide range of conditions. The proposed system uniquely demonstrates same-electrode stimulation and recording, with neural signal recovery in presence of stimulation artifact 100 dB larger in magnitude than the underlying signals. The system is tested both in vitro and in vivo, during concurrent stimulation and recording on the same electrode. In vivo results in a rodent model are compared to recordings made by a commercial neural amplifier system connected in parallel.
- 4 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (3) , 601-613
Open AccessOnline Artifact Cancelation in Same-Electrode Neural Stimulation and Recording Using a Combined Hardware and Software Architecture
Advancing studies of neural network dynamics and developments of closed-loop neural interfaces requires the ability to simultaneously stimulate and record the neural cells. Recording adjacent to or at the stimulation site produces artifact signals that are orders of magnitude larger than the neural responses of interest. These signals often saturate the recording amplifier causing distortion or loss of short-latency evoked responses. This paper proposes a method to cancel the artifact in simultaneous neural recording and stimulation on the same electrode. By combining a novel hardware architecture with concurrent software processing, the design achieves neural signal recovery in a wide range of conditions. The proposed system uniquely demonstrates same-electrode stimulation and recording, with neural signal recovery in presence of stimulation artifact 100 dB larger in magnitude than the underlying signals. The system is tested both in vitro and in vivo, during concurrent stimulation and recording on the same electrode. In vivo results in a rodent model are compared to recordings made by a commercial neural amplifier system connected in parallel.