Alexander E. Isaev
Alexander E. Isaev has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Anton N. Matveev
Russian Metrological Institute of Technical Physics and Radio Engineering
11 shared publications A. N. Matveev
Russian Metrological Institute of Technical Physics and Radio Engineering
7 shared publicationsI. V. Chernikov
All-Russia Research Institute of Physicotechnical and Radio Measurements (VNIIFTRI), Mendeleevo, Russia
6 shared publicationsA. S. Nikolaenko
All-Russia Research Institute of Physicotechnical and Radio Measurements (VNIIFTRI)
5 shared publicationsG. S. Nekrich
All-Russia Research Institute of Physicotechnical and Radio Measurements (VNIIFTRI)
5 shared publications- Nikolay G. Shcherblyuk
Russian Metrological Institute of Technical Physics and Radio Engineering
5 shared publications
Latest Publications
- 1 October 2025
- Published by Springer Nature in Measurement Techniques
- Vol. 68 (7-8) , 464-472
Phase-pulse method for estimating the sonic interval transit time when measuring the speed of sound in aqueous media
- 1 October 2025
- Published by Springer Nature in Measurement Techniques
- Vol. 68 (7-8) , 464-472
Phase-pulse method for estimating the sonic interval transit time when measuring the speed of sound in aqueous media
- 4 September 2025
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- Vol. 74 (4) , 74-81
Phase-pulse method for estimating the traveling time of a sound wave when measuring the speed of sound in a water medium
The article considers the issues of increasing the accuracy of sound speed measurements in water actual both for standard installations and small-sized autonomous measuring devices. The methods for estimating the sound wave propagation time when measuring the sound speed using the time-of-flight method with a variable base are discussed. The general disadvantages of these methods are shown: low noise immunity of measurements, a small number of characteristic points of signals used to estimate time intervals, and the subjectivity of their selection. A version of the phase-pulse method is proposed that allows obtaining an integral estimate of the sound wave propagation time. A theoretical justification for the applicability of the method for measuring the sound speed in water is given. The propagation time is estimated by the frequency dependence of the sound wave phase incursion, which is obtained as the difference in phase spectra (cross phase spectrum) of copies of broadband pulses spaced apart in reception time. In the absence of sound dispersion, the cross phase spectrum is a proportional frequency dependence of the phase advance of a sound wave. Approximating the cross phase spectrum with a linear regression model, the frequency dependence is transformed into a numerical parameter, equal to the travel time of a sound wave with an accuracy of 2π.Using the cross phase spectrum allows us to exclude the subjective factor when choosing characteristic points of the signals, control the quality of the experiment, significantly increase the noise immunity of measurements, and improve the statistical characteristics of the resulting estimate. An experiment is described to test the proposed method. The obtained estimates of the speed of sound are not inferior in accuracy to empirical formulas and standardized tabular values. The obtained results will be useful in further research aimed at increasing the accuracy of sound speed measurements using the phase-pulse method to the accuracy required for reference installations.
- 4 September 2025
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- Vol. 74 (4) , 74-81
Phase-pulse method for estimating the traveling time of a sound wave when measuring the speed of sound in a water medium
The article considers the issues of increasing the accuracy of sound speed measurements in water actual both for standard installations and small-sized autonomous measuring devices. The methods for estimating the sound wave propagation time when measuring the sound speed using the time-of-flight method with a variable base are discussed. The general disadvantages of these methods are shown: low noise immunity of measurements, a small number of characteristic points of signals used to estimate time intervals, and the subjectivity of their selection. A version of the phase-pulse method is proposed that allows obtaining an integral estimate of the sound wave propagation time. A theoretical justification for the applicability of the method for measuring the sound speed in water is given. The propagation time is estimated by the frequency dependence of the sound wave phase incursion, which is obtained as the difference in phase spectra (cross phase spectrum) of copies of broadband pulses spaced apart in reception time. In the absence of sound dispersion, the cross phase spectrum is a proportional frequency dependence of the phase advance of a sound wave. Approximating the cross phase spectrum with a linear regression model, the frequency dependence is transformed into a numerical parameter, equal to the travel time of a sound wave with an accuracy of 2π.Using the cross phase spectrum allows us to exclude the subjective factor when choosing characteristic points of the signals, control the quality of the experiment, significantly increase the noise immunity of measurements, and improve the statistical characteristics of the resulting estimate. An experiment is described to test the proposed method. The obtained estimates of the speed of sound are not inferior in accuracy to empirical formulas and standardized tabular values. The obtained results will be useful in further research aimed at increasing the accuracy of sound speed measurements using the phase-pulse method to the accuracy required for reference installations.
- 1 September 2025
- Published by Springer Nature in Measurement Techniques
- Vol. 68 (5-6) , 335-340
Determination of the hydrophone phase response during periodic calibrations
- 1 September 2025
- Published by Springer Nature in Measurement Techniques
- Vol. 68 (5-6) , 335-340
Determination of the hydrophone phase response during periodic calibrations
- 14 July 2025
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- Vol. 74 (3) , 79-83
Determination of the hydrophone phase response during periodic calibrations
Traditional amplitude calibration, which is why its results depend on the art of the experimenter. A calculation method for determining the phase response of a hydrophone is proposed, which makes it possible to reduce the labor intensity of its periodic calibrations. Based on the experimentally confirmed applicability of the minimum-phase system concept to a hydrophone, the calibrated hydrophone is represented by a model in the form of an advance link and a minimum-phase fourpole network. Based on the results of the primary calibration, the equivalent radius of the hydrophone determine. No phase measurements are performed during periodic calibrations. The amplitude response of sensitivity is determined, according to which, using the Hilbert transform, the minimum phase response of the hydrophone is calculated. The phase response of the hydrophone sensitivity is obtained as the sum of the minimum phase response and the frequency dependence of the phase incursion of the sound wave during its propagation in water over a distance equal to the equivalent radius of the hydrophone. An experiment to determine the equivalent radius of a hydrophone is described. Using the calculation method, the labor intensity of periodic verification is reduced many times over, the load is reduced, and the resource of a specialized measurement standard is saved, since the need to use high-rank standards during periodic calibrations disappears.
- 14 July 2025
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- Vol. 74 (3) , 79-83
Determination of the hydrophone phase response during periodic calibrations
Traditional amplitude calibration, which is why its results depend on the art of the experimenter. A calculation method for determining the phase response of a hydrophone is proposed, which makes it possible to reduce the labor intensity of its periodic calibrations. Based on the experimentally confirmed applicability of the minimum-phase system concept to a hydrophone, the calibrated hydrophone is represented by a model in the form of an advance link and a minimum-phase fourpole network. Based on the results of the primary calibration, the equivalent radius of the hydrophone determine. No phase measurements are performed during periodic calibrations. The amplitude response of sensitivity is determined, according to which, using the Hilbert transform, the minimum phase response of the hydrophone is calculated. The phase response of the hydrophone sensitivity is obtained as the sum of the minimum phase response and the frequency dependence of the phase incursion of the sound wave during its propagation in water over a distance equal to the equivalent radius of the hydrophone. An experiment to determine the equivalent radius of a hydrophone is described. Using the calculation method, the labor intensity of periodic verification is reduced many times over, the load is reduced, and the resource of a specialized measurement standard is saved, since the need to use high-rank standards during periodic calibrations disappears.
- 13 January 2025
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- Vol. 73 (12) , 46-54
VNIIFTRI reference base in the field of underwater acoustic measurements: metrological characteristics, functional capabilities, innovations and prospects for improving standards
The updated VNIIFTRI’s underwater acoustic reference base is described. The article provides information about a special multifunctional metrological water tank, an underwater acoustic excess pressure tank, metrological characteristics of reference facilities of state primary standard of units of sound pressure and oscillating velocity in the water media GET 55-2017, state primary standard of the unit of ultrasound power in water GET 169-2019, state primary standard of the unit of sound velocity in liquid media GET 201-2012. A model of a hydrophone as an operational link and a minimum-phase four-terminal network is proposed, the concept of energy sensitivity in frequency bands is introduced, a method for determining the effective size of a hydrophone and obtaining its minimum-phase frequency response of sensitivity is proposed, implemented in GET 55-2017. A method for representing the complex frequency response of sensitivity by a formula is proposed, and requirements for the functionality of a digital metrology platform are formulated. GET 169-2019 is supplemented with two facilities for reproducing units of intensity and pressure of ultrasound in water, which will make it possible to find a comprehensive solution to the problem of metrological support for ultrasound medical and other equipment manufactured and used in Russia. GET 201-2012 is supplemented with a facility for reproducing and transmitting the unit of sound velocity in water using the time-of-flight pulse method with a variable base. The change in the base length is measured using the optical interference method, and the time delay is measured using characteristic points of pulse signals. Prospects for improving primary standards are discussed. Attention is drawn to the problems that have arisen in the participation of the Russia in international comparisons and possible ways to solve them.
- 13 January 2025
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- Vol. 73 (12) , 46-54
VNIIFTRI reference base in the field of underwater acoustic measurements: metrological characteristics, functional capabilities, innovations and prospects for improving standards
The updated VNIIFTRI’s underwater acoustic reference base is described. The article provides information about a special multifunctional metrological water tank, an underwater acoustic excess pressure tank, metrological characteristics of reference facilities of state primary standard of units of sound pressure and oscillating velocity in the water media GET 55-2017, state primary standard of the unit of ultrasound power in water GET 169-2019, state primary standard of the unit of sound velocity in liquid media GET 201-2012. A model of a hydrophone as an operational link and a minimum-phase four-terminal network is proposed, the concept of energy sensitivity in frequency bands is introduced, a method for determining the effective size of a hydrophone and obtaining its minimum-phase frequency response of sensitivity is proposed, implemented in GET 55-2017. A method for representing the complex frequency response of sensitivity by a formula is proposed, and requirements for the functionality of a digital metrology platform are formulated. GET 169-2019 is supplemented with two facilities for reproducing units of intensity and pressure of ultrasound in water, which will make it possible to find a comprehensive solution to the problem of metrological support for ultrasound medical and other equipment manufactured and used in Russia. GET 201-2012 is supplemented with a facility for reproducing and transmitting the unit of sound velocity in water using the time-of-flight pulse method with a variable base. The change in the base length is measured using the optical interference method, and the time delay is measured using characteristic points of pulse signals. Prospects for improving primary standards are discussed. Attention is drawn to the problems that have arisen in the participation of the Russia in international comparisons and possible ways to solve them.
- 1 April 2024
- Published by Springer Nature in Measurement Techniques
- Vol. 67 (1) , 79-86
Key comparison CCAUV.W-K2: features of hydrophone calibration
- 1 April 2024
- Published by Springer Nature in Measurement Techniques
- Vol. 67 (1) , 79-86
Key comparison CCAUV.W-K2: features of hydrophone calibration
- 8 March 2024
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- No. 1,p. 67-72
Key comparison CCAUV.W-K2: features of hydrophone calibration
The results of key comparison are the most convincing and objective indicator of confirmation of the correctness and accuracy of the newly developed measurement method. The results of comparison and measurement methods applied at the second key comparison of national standards of the unit of sound pressure in water CCAUV.W-K2, organized by the Consultative Committee for Acoustics, Ultrasound and Vibration of the International Committee for Weights and Measures, are described. A feature of the comparison is that the calibration range has been expanded into the low frequency region by two octaves compared to the first key comparison CCAUV.W-K1. The results of the CCAUV.W-K2 comparison were considered successful. Important scientific results of participation in the comparison were confirmation of: the correctness of the hydrophone free-field calibration methods developed at VNIIFTRI (at ultra-low frequencies for a sound-reflecting water tank and in the noise reverberant sound field of the water tank), the equivalence of the calibration results when radiating signals of various types: chirp, noise and ton-burst. In the process of performing control calibrations, the pilot laboratory discovered violations of the stability of the reference hydrophone of comparison. When comparing the results obtained by participants, there was an increase in the discrepancy between the results in the frequency range 60–100 kHz, which is considered the least problematic.
- 8 March 2024
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- No. 1,p. 67-72
Key comparison CCAUV.W-K2: features of hydrophone calibration
The results of key comparison are the most convincing and objective indicator of confirmation of the correctness and accuracy of the newly developed measurement method. The results of comparison and measurement methods applied at the second key comparison of national standards of the unit of sound pressure in water CCAUV.W-K2, organized by the Consultative Committee for Acoustics, Ultrasound and Vibration of the International Committee for Weights and Measures, are described. A feature of the comparison is that the calibration range has been expanded into the low frequency region by two octaves compared to the first key comparison CCAUV.W-K1. The results of the CCAUV.W-K2 comparison were considered successful. Important scientific results of participation in the comparison were confirmation of: the correctness of the hydrophone free-field calibration methods developed at VNIIFTRI (at ultra-low frequencies for a sound-reflecting water tank and in the noise reverberant sound field of the water tank), the equivalence of the calibration results when radiating signals of various types: chirp, noise and ton-burst. In the process of performing control calibrations, the pilot laboratory discovered violations of the stability of the reference hydrophone of comparison. When comparing the results obtained by participants, there was an increase in the discrepancy between the results in the frequency range 60–100 kHz, which is considered the least problematic.
- 12 June 2023
- Published by Springer Nature in Measurement Techniques
- Vol. 66 (3) , 211-216
Results of Pilot Comparisons of Amplitude–Phase Calibrations of Hydrophones in the Frequency Range 10–500 kHz COOMET 786/RU-a/19
- 12 June 2023
- Published by Springer Nature in Measurement Techniques
- Vol. 66 (3) , 211-216
Results of Pilot Comparisons of Amplitude–Phase Calibrations of Hydrophones in the Frequency Range 10–500 kHz COOMET 786/RU-a/19
- 14 April 2023
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- No. 3,p. 67-72
Results of pilot comparisons of amplitude-phase calibrations of hydrophones in the frequency range 10–500 kHz COOMET 786/RU-а/19
Результаты пилотных сличений амплитудно-фазовых калибровок гидрофонов в частотном диапазоне 10–500 кГц КООМЕТ 786/RU-а/19
- 14 April 2023
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- No. 3,p. 67-72
Results of pilot comparisons of amplitude-phase calibrations of hydrophones in the frequency range 10–500 kHz COOMET 786/RU-а/19
Результаты пилотных сличений амплитудно-фазовых калибровок гидрофонов в частотном диапазоне 10–500 кГц КООМЕТ 786/RU-а/19