Nikolay G. Shcherblyuk
Research Subjects
Nikolay G. Shcherblyuk has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Dmitri V. Gal'Tsov
Moscow State University
7 shared publications - Alexander E. Isaev
Russian Metrological Institute of Technical Physics and Radio Engineering, Mendeleevo, Russian Federation
5 shared publications - Anton N. Matveev
Russian Metrological Institute of Technical Physics and Radio Engineering
4 shared publications - B. I. Khatamtaev
Russian Metrological Institute of Technical Physics and Radio Engineering (VNIIFTRI), Mendeleevo, Russia
2 shared publications - Bulat I. Khatamtaev
Russian Metrological Institute of Technical Physics and Radio Engineering
2 shared publications - Chiang-Mei Chen
National Central University
2 shared publications
Latest Publications
- 19 June 2026
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- Vol. 75 (3) , 20-31
State primary standard of units of sound pressure and vibrational velocity in aquatic environments GET 55-2025
The issues of calibration of underwater noise measurement instruments, which in modern hydroacoustics are represented by hydroacoustic measurement instruments – primary transducers and underwater measuring systems based on primary transducers, are considered. Much attention is paid to laboratory calibrations in water tank conditions of underwater measuring systems, the dimensions of which are several times larger than the dimensions of the primary transducers used in them. Such underwater measuring systems have signifi cant sensitivity nonuniformity, therefore their amplitude and phase frequency characteristics must be measured in a free fi eld with high frequency resolution and underwater measuring systems must be calibrated in frequency bands. The geographic range of application for hydroacoustic measurement instruments, from southern latitudes to northern ones (in the Northern Sea Route), requires studying the dependence of their metrological characteristics on changes in water temperature and excess hydrostatic pressure across the entire operating frequency range from a few hertz to hundreds of kilohertz. Modern underwater sonar and communication technologies require methods and instruments for measuring the phase sensitivity characteristics of primary transducers. To solve the above-mentioned issues, the State primary standard of units of sound pressure and vibrational velocity in aquatic environments GET 55-2017 was improved, which allowed the transfer of units only to primary transducers at one-third-octave frequencies and the calibration of primary transducer under excess pressure only in a limited frequency range of 5–500 Hz at water temperature of 15–25 °C. As a result of the conducted research, the metrological characteristics of the standard GET 55-2017 were improved and its functional capabilities were expanded, and the State primary standard of units of sound pressure and vibrational velocity in aquatic environments GET 55-2025 was approved. The stated goals were achieved through the inclusion in GET 55-2025 of new-generation measuring facilities and a unique hydroacoustic equipment complex developed at VNIIFTRI. The metrological characteristics of GET 55-2025 are presented. The reference facilities and hydroacoustic equipment included in GET 55-2025 are described. As a result, GET 55-2025 implements and ensures the reproduction and transfer of the unit of sound pressure in the aquatic environment with a minimum frequency step of 1 Hz in the range of 500–1·10 6 Hz, studies of the characteristics of hydroacoustic measuring instruments in a free fi eld in the range of 2–500 kHz at an excess pressure of up to 15 MPa and an aquatic temperature of 4–35 °C, measurement of the phase-frequency characteristics of the sensitivity of primary transducers in the frequency range of 50–200 kHz, measurement of the frequency characteristics of the sensitivity of underwater measuring systems, the length of which does not exceed 3 m and weighing no more than 50 kg, in the frequency range of 1–250 kHz with a frequency resolution of 1 Hz, and also reproduction and transfer of the unit of the phase angle of sensitivity of primary transducers. GET 55-2025 ensured the principle of advanced development of metrology in hydroacoustics.
- 19 June 2026
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- Vol. 75 (3) , 20-31
State primary standard of units of sound pressure and vibrational velocity in aquatic environments GET 55-2025
The issues of calibration of underwater noise measurement instruments, which in modern hydroacoustics are represented by hydroacoustic measurement instruments – primary transducers and underwater measuring systems based on primary transducers, are considered. Much attention is paid to laboratory calibrations in water tank conditions of underwater measuring systems, the dimensions of which are several times larger than the dimensions of the primary transducers used in them. Such underwater measuring systems have signifi cant sensitivity nonuniformity, therefore their amplitude and phase frequency characteristics must be measured in a free fi eld with high frequency resolution and underwater measuring systems must be calibrated in frequency bands. The geographic range of application for hydroacoustic measurement instruments, from southern latitudes to northern ones (in the Northern Sea Route), requires studying the dependence of their metrological characteristics on changes in water temperature and excess hydrostatic pressure across the entire operating frequency range from a few hertz to hundreds of kilohertz. Modern underwater sonar and communication technologies require methods and instruments for measuring the phase sensitivity characteristics of primary transducers. To solve the above-mentioned issues, the State primary standard of units of sound pressure and vibrational velocity in aquatic environments GET 55-2017 was improved, which allowed the transfer of units only to primary transducers at one-third-octave frequencies and the calibration of primary transducer under excess pressure only in a limited frequency range of 5–500 Hz at water temperature of 15–25 °C. As a result of the conducted research, the metrological characteristics of the standard GET 55-2017 were improved and its functional capabilities were expanded, and the State primary standard of units of sound pressure and vibrational velocity in aquatic environments GET 55-2025 was approved. The stated goals were achieved through the inclusion in GET 55-2025 of new-generation measuring facilities and a unique hydroacoustic equipment complex developed at VNIIFTRI. The metrological characteristics of GET 55-2025 are presented. The reference facilities and hydroacoustic equipment included in GET 55-2025 are described. As a result, GET 55-2025 implements and ensures the reproduction and transfer of the unit of sound pressure in the aquatic environment with a minimum frequency step of 1 Hz in the range of 500–1·10 6 Hz, studies of the characteristics of hydroacoustic measuring instruments in a free fi eld in the range of 2–500 kHz at an excess pressure of up to 15 MPa and an aquatic temperature of 4–35 °C, measurement of the phase-frequency characteristics of the sensitivity of primary transducers in the frequency range of 50–200 kHz, measurement of the frequency characteristics of the sensitivity of underwater measuring systems, the length of which does not exceed 3 m and weighing no more than 50 kg, in the frequency range of 1–250 kHz with a frequency resolution of 1 Hz, and also reproduction and transfer of the unit of the phase angle of sensitivity of primary transducers. GET 55-2025 ensured the principle of advanced development of metrology in hydroacoustics.
- 1 April 2024
- Published by Springer Nature in Measurement Techniques
- Vol. 67 (1) , 79-86
Key comparison CCAUV.W-K2: features of hydrophone calibration
- 1 April 2024
- Published by Springer Nature in Measurement Techniques
- Vol. 67 (1) , 79-86
Key comparison CCAUV.W-K2: features of hydrophone calibration
- 8 March 2024
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- No. 1,p. 67-72
Key comparison CCAUV.W-K2: features of hydrophone calibration
The results of key comparison are the most convincing and objective indicator of confirmation of the correctness and accuracy of the newly developed measurement method. The results of comparison and measurement methods applied at the second key comparison of national standards of the unit of sound pressure in water CCAUV.W-K2, organized by the Consultative Committee for Acoustics, Ultrasound and Vibration of the International Committee for Weights and Measures, are described. A feature of the comparison is that the calibration range has been expanded into the low frequency region by two octaves compared to the first key comparison CCAUV.W-K1. The results of the CCAUV.W-K2 comparison were considered successful. Important scientific results of participation in the comparison were confirmation of: the correctness of the hydrophone free-field calibration methods developed at VNIIFTRI (at ultra-low frequencies for a sound-reflecting water tank and in the noise reverberant sound field of the water tank), the equivalence of the calibration results when radiating signals of various types: chirp, noise and ton-burst. In the process of performing control calibrations, the pilot laboratory discovered violations of the stability of the reference hydrophone of comparison. When comparing the results obtained by participants, there was an increase in the discrepancy between the results in the frequency range 60–100 kHz, which is considered the least problematic.
- 8 March 2024
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- No. 1,p. 67-72
Key comparison CCAUV.W-K2: features of hydrophone calibration
The results of key comparison are the most convincing and objective indicator of confirmation of the correctness and accuracy of the newly developed measurement method. The results of comparison and measurement methods applied at the second key comparison of national standards of the unit of sound pressure in water CCAUV.W-K2, organized by the Consultative Committee for Acoustics, Ultrasound and Vibration of the International Committee for Weights and Measures, are described. A feature of the comparison is that the calibration range has been expanded into the low frequency region by two octaves compared to the first key comparison CCAUV.W-K1. The results of the CCAUV.W-K2 comparison were considered successful. Important scientific results of participation in the comparison were confirmation of: the correctness of the hydrophone free-field calibration methods developed at VNIIFTRI (at ultra-low frequencies for a sound-reflecting water tank and in the noise reverberant sound field of the water tank), the equivalence of the calibration results when radiating signals of various types: chirp, noise and ton-burst. In the process of performing control calibrations, the pilot laboratory discovered violations of the stability of the reference hydrophone of comparison. When comparing the results obtained by participants, there was an increase in the discrepancy between the results in the frequency range 60–100 kHz, which is considered the least problematic.
- 12 June 2023
- Published by Springer Nature in Measurement Techniques
- Vol. 66 (3) , 211-216
Results of Pilot Comparisons of Amplitude–Phase Calibrations of Hydrophones in the Frequency Range 10–500 kHz COOMET 786/RU-a/19
- 12 June 2023
- Published by Springer Nature in Measurement Techniques
- Vol. 66 (3) , 211-216
Results of Pilot Comparisons of Amplitude–Phase Calibrations of Hydrophones in the Frequency Range 10–500 kHz COOMET 786/RU-a/19
- 14 April 2023
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- No. 3,p. 67-72
Results of pilot comparisons of amplitude-phase calibrations of hydrophones in the frequency range 10–500 kHz COOMET 786/RU-а/19
Результаты пилотных сличений амплитудно-фазовых калибровок гидрофонов в частотном диапазоне 10–500 кГц КООМЕТ 786/RU-а/19
- 14 April 2023
- Published by Federal Budgetary Institution "Research Center for Applied Metrology - Rostest" in Izmeritel`naya Tekhnika
- No. 3,p. 67-72
Results of pilot comparisons of amplitude-phase calibrations of hydrophones in the frequency range 10–500 kHz COOMET 786/RU-а/19
Результаты пилотных сличений амплитудно-фазовых калибровок гидрофонов в частотном диапазоне 10–500 кГц КООМЕТ 786/RU-а/19
- 1 January 2023
- Published by Springer Nature in Measurement Techniques
- Vol. 65 (10) , 763-768
Experimental Determination of the Acoustic Center of a Measuring Hydrophone
- 1 January 2023
- Published by Springer Nature in Measurement Techniques
- Vol. 65 (10) , 763-768
Experimental Determination of the Acoustic Center of a Measuring Hydrophone
- 1 September 2020
- Published by Springer Nature in Measurement Techniques
- Vol. 63 (6) , 487-492
Standard Installation for the Transmission of Units of Sound Pressure in the Ultrasonic Frequency Range
- 1 September 2020
- Published by Springer Nature in Measurement Techniques
- Vol. 63 (6) , 487-492
Standard Installation for the Transmission of Units of Sound Pressure in the Ultrasonic Frequency Range
- Open Access
Three-charge 2J black ring
Using recently proposed new solution generating technique, we construct the charged version of Pomeranski-Senkov doubly rotating black ring in the $U(1)^3$ five-dimensional supergravity. For arbitrary values of charges the solution is unbalanced, but the Dirac-Misner string is removed when two of the charges are set to zero. In this particular case our solution can be uplifted to some solution of six-dimensional vacuum gravity.Open AccessThree-charge 2J black ring
Using recently proposed new solution generating technique, we construct the charged version of Pomeranski-Senkov doubly rotating black ring in the $U(1)^3$ five-dimensional supergravity. For arbitrary values of charges the solution is unbalanced, but the Dirac-Misner string is removed when two of the charges are set to zero. In this particular case our solution can be uplifted to some solution of six-dimensional vacuum gravity. - Open Access
Hidden symmetries in 5D supergravities and black rings
We construct generating technique for 5D minimal and $U(1)^3$ supergravities based on hidden symmetries arising in dimensional reduction to three dimensions. In the three-vector case the symmetry is SO(4,4), and the minimal case corresponds to contraction of this group to $G_{2(2)}$. The matrix representation is presented applicable to both cases and the generating transformations preserving an asymptotic structure are listed. Our transformations contain enough free parameters to construct the general charged black ring in $U(1)^3$ theory starting with known solutions. To avoid a complicated inverse dualisation in the component form we introduce the matrix-valued dualisation which opens the way to derive new solutions purely algebraically from the coset representation of the seed.Open AccessHidden symmetries in 5D supergravities and black rings
We construct generating technique for 5D minimal and $U(1)^3$ supergravities based on hidden symmetries arising in dimensional reduction to three dimensions. In the three-vector case the symmetry is SO(4,4), and the minimal case corresponds to contraction of this group to $G_{2(2)}$. The matrix representation is presented applicable to both cases and the generating transformations preserving an asymptotic structure are listed. Our transformations contain enough free parameters to construct the general charged black ring in $U(1)^3$ theory starting with known solutions. To avoid a complicated inverse dualisation in the component form we introduce the matrix-valued dualisation which opens the way to derive new solutions purely algebraically from the coset representation of the seed.