HBHatice Biltekin

Hatice Biltekin

*This is an algorithmically generated author record based on publicly available information.

Hatice Biltekin has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Image Enhancement Filters on the Detection of Periapical Radiolucent Lesions on Panoramic Radiographs: A Multi-Reader Multi-Case Study

    by Ozlem Busra Dogan, Hatice Biltekin

    Background: Panoramic radiography is widely used in dental practice, but its two-dimensional projection geometry and anatomical superimposition can obscure periapical radiolucent lesions, particularly in the maxillary anterior region and for novice observers. Methods: This retrospective multi-reader, multi-case study aimed to evaluate the effects of unsharp mask and Gaussian blur filters on the diagnostic performance and interobserver agreement of novice observers in detecting periapical radiolucent lesions on panoramic radiographs. Twenty final-year dental students evaluated 56 panoramic radiographs (28 lesion-positive and 28 lesion-free cases; 224 maxillary anterior teeth) under three imaging conditions (original, unsharp mask, and Gaussian blur). Observers scored lesion presence using a five-point confidence scale. Diagnostic performance (AUC, sensitivity, and specificity) was compared using the Dorfman–Berbaum–Metz/Obuchowski–Rockette multi-reader, multi-case method. Interobserver agreement was assessed using quadratic-weighted Cohen’s kappa and the intraclass correlation coefficient (ICC). Results: Imaging condition significantly affected AUC, sensitivity, and specificity (all p ≤ 0.003). Compared with original images, unsharp mask significantly improved sensitivity (78.2% vs. 52.5%), specificity (90.2% vs. 83.2%), and AUC (0.876 vs. 0.737) (all p < 0.05), with the highest interobserver agreement (ICC = 0.951; κ = 0.476). Gaussian blur significantly reduced sensitivity (40.2%) and AUC (0.655) compared with original images (both p < 0.001). Conclusions: Unsharp mask filtering was associated with improved diagnostic performance and interobserver agreement among novice observers, whereas Gaussian blur was associated with reduced lesion detection performance. These findings suggest that unsharp mask filtering may have potential as an adjunct to radiographic interpretation training.

  • Mechanism-Based Classification and Quantitative Assessment of Panoramic Radiographic Artifacts

    by Özlem Büşra Doğan, Hatice Biltekin

    Background and Aim: Accurate identification of panoramicradiographic artifacts is essential for improving diagnosticreliability and reducing unnecessary repeat imaging. This studyaimed to classify panoramic radiographic artifacts by theirformation mechanisms and evaluate image quality using thecumulative artifact burden based on total artifact count.Materials and Methods: This retrospective study included 500panoramic radiographs. Images were classified into eight artifactcategories, and the cumulative artifact burden was calculated fromthe total artifact count. Inter-observer agreement was assessedusing Cohen’s kappa(κ), and reliability of the total artifact countusing the intraclass correlation coefficient (ICC).Results: A total of 500 panoramic radiographs were evaluated. Atleast one artifact was identified in 92.0% of radiographs, whereasonly 8.0% were artifact-free. According to the predefined imagequality classification, 8.0% of radiographs were classified asexcellent, 62.6% as acceptable, and 29.4% as unacceptable.Air space–related soft tissue artifacts were the most frequentfindings, with improper tongue positioning observed in 43.6% ofimages. Transverse and vertical positioning artifacts were alsocommon, whereas motion artifacts were relatively infrequent(3.0%). Inter-observer agreement demonstrated substantial toalmost perfect reliability, with Cohen’s kappa values ranging from0.80 to 0.92 and excellent agreement for total artifact countassessment (ICC = 0.958).Conclusion: A mechanism-based classification combinedwith an artifact count–based burden assessment may providea structured approach for evaluating panoramic imagequality, although further validation is needed to determine itsrelationship with diagnostic acceptability.

  • Open Access

    Dental undergraduate students' ability in diagnosing horizontal root fractures: a comparative analysis using CBCT and periapical radiography

    by Çiğdem Şeker, Hatice Biltekin, İsMail Çapar, Rabia Çayır Aras, Gediz Geduk, Murat İçEn

    Aims: Accurate radiographic diagnosis of horizontal root fractures is challenging and represents a key competency expected of undergraduate dental students. Although cone-beam computed tomography (CBCT) overcomes limitations of two-dimensional imaging, its impact on diagnostic consistency among dental students remains insufficiently explored. This study aimed to evaluate dental students’ ability to detect horizontal root fractures using different imaging techniques.Methods: This in vitro study included 35 extracted permanent maxillary and mandibular incisors and canines, 25 of which had artificially induced horizontal root fractures and 10 used as healthy controls. Periapical radiographs and CBCT images were obtained for all samples. Image interpretation was performed independently by 25 final-year dental students and a dentomaxillofacial radiology (DMFR) specialist. The fracture status recorded during sample preparation was used as the reference standard. Inter-observer agreement between each student and the expert was assessed using Cohen's kappa statistic, and diagnostic performance parameters were calculated.Results: In the evaluation of periapical radiographs, the agreement between students and the expert varied (0.364-1). In the evaluation of CBCT images, the vast majority of students (n=23) showed almost perfect agreement with the expert (0.851-1). In terms of diagnostic performance, the use of CBCT provided more consistent sensitivity, specificity, and accuracy values compared to periapical radiography; sensitivity and specificity were generally found to be above 90% in cases evaluated with CBCT. The DMFR specialist demonstrated high diagnostic performance in both imaging methods, and it was observed that the performance difference between students and specialist decreased with the use of CBCT. Diagnostic accuracy values ranged from 68.6% to 100% for periapical radiography and from 82.9% to 100% for CBCT.Conclusion: Altough the final-year dental students included in this study had significantly more hands-on experience in acquiring and interpreting periapical radiographs and had only received basic theoretical CBCT training with limited practical and clinical experience, CBCT use was associated with more consistent diagnostic performance among the students.

  • PANORAMİK RADYOGRAFLARDA APİKAL PATOLOJİ TEŞHİSİ İÇİN YAPAY ZEKA YETERLİ GÜVENİLİRLİK DÜZEYİNE ULAŞTI MI: FARKLI EŞİK DEĞERLERDE KARŞILAŞTIRMALI ÇALIŞMA

    by Gediz Geduk, Hatice Bi̇lTeki̇n, Çiğdem Şeker

    Amaç: Panoramik radyografiler üzerinden tespit edilen apikal patolojilerin yapay zekâ temelli ticari bir yazılım ile doğruluğunun tespit edilmesidir. Gereç ve yöntem: En az bir tane apikal patolojinin olduğu 100 panoramik radyograf seçilmiş ve Denti.AI ticari yazılımına yüklenmiştir. Sistemin %30, %60, %90 eşik değerlerinde apikal patolojiyi tespit etmesi sağlanmıştır. Panoramik radyografiler Ağız, Diş ve Çene Radyolojisi alanında uzmanlığını almış iki hekim ve Ağız, Diş ve Çene Radyolojisi uzmanlık eğitimini sürdüren iki araştırma görevlisi tarafından seçilmiştir. Verilerin analizi SPSS 22.0 Paket Veri Programı ile yapılmıştır. Bulgular: Çalışmanın sonunda %30, %60, %90 eşik değerleri için sensivite değerleri sırasıyla %62.6, %38.1 ve %6.8, spesifite değerleri %0, %100 ve %100, tanısal doğruluk değerleri 61.3, 39.3 ve 8.6 olarak bulunmuştur. PPV değerleri %96.8, 100 ve 100, NPV değerleri 0, 3.2 ve 2.1, AUC değerleri ise 0.313, 0.69 ve 0.534 olarak hesaplanmıştır. İstatistiki testlerde p<0.05 değeri anlamlı olarak kabul edilmiştir. Sonuç: Yapay zekâ programı, özellikle eşik değer düşürüldüğü zaman uzman hekimlere yakın sonuçlar vermektedir. Bu şekilde hazırlanan yapay zekâ tabanlı ticari yazılımlarda örnek sayılarının artışı ve bunların geriye dönük tespit edilmesinin doğruluğu artıracağını, bu tip yazılımların klinik tanılarda daha çok yer alacağını ve yoğun kliniklerde başvurulabilecek bir destek sistemi olabileceğini düşünmekteyiz.


  • Assessment of Knowledge and Concern of Dental Patients During Coronavirus Disease 2019 (COVID-19) Pandemic: Survey Study

    by Gediz Geduk, Gaye Sağlam, Hatice Bi̇lteki̇n

    Amaç: Korona Virus Hastalığı 2019 (COVID-19), Dünya Sağlık Örgütü (DSÖ) tarafından, tüm dünyadaki insanları etkileyen küresel bir halk sağlığı acil durumu olarak ilan edildi. Bu çalışmanın amacı, COVID-19 salgını sırasında diş hekimine başvuran hastaların COVID-19 hakkında bilgi ve endişelerini değerlendirmektir. Gereç ve Yöntemler: Temmuz-Ekim 2020 tarihleri arasında Zonguldak Bülent Ecevit Üniversitesi Diş Hekimliği fakültesine başvuran 400 hastaya, COVID-19 salgını ile ilgili anket yapıldı. Elde edilen verilerin istatistiksel anlamlılık farkını analiz etmek için ki-karetesti kullanıldı. P


  • Evaluation of the Distance Education Model in the Coronavirus (Covid-19) Pandemia

    by Gediz Geduk, Çiğdem Şeker, Hatice Bi̇lteki̇n, Emre Haylaz

    Purpose:The aim of this study is to question and evaluate the perceptions of 3rd, 4thand 5thyear undergraduate dentalstudents towards distance education practices and the roles of faculty members in the implementation of educationduring the Covid-19 pandemic.Materials & Methods:An online survey was applied to 149 volunteers, consisting of 3rd, 4thand 5thyear undergraduatedental students. The survey composed of 12 questions about distance education and shared from "Google Forms"application. Data analysis was done with SPSS 22.0 Packet Data Program.Results:One hundred forty-nine undergraduate dental students, including 54 third-year students, 60 fourth-yearstudents and 35 fifth-year students, answered the survey on a voluntary basis. Upon this, each answer was examinedseparately, and efforts were made to reach conclusions about the distance education model. When results were evaluated,the majority of the students (40.9%) who participated in the survey reported that the distance education modelcontributed to the theoretical lessons, when adequacy of the practical training was assessed, it was concluded thatdistance education was "Absolutely Inadequate" at with a 79.9 percentageConclusion:As a result of the study, most of the students found the distance education model sufficient for theoreticalcourses, but insufficient for practical education and found traditional practical education more advantageous.