Michael Sullivan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Michael Sullivan has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Darius Brynes
Elettra-Sincrotrone Trieste S.C.p.A.
1 shared publication - Annie Héroux
Former Elettra – Sincrotrone Trieste SCpA, SS 14 km 163,5 in AREA Science Park, Basovizza, 34149 Trieste, Italy
1 shared publication - Erik M. Muller
Instrumentation Department, Brookhaven National Laboratory, PO 5000, Upton, NY 11973, U.S.A.
1 shared publication - Gianluigi De Geronimo
Nuclear Engineering and Radiological Sciences (NERS) Department, University of Michigan, Ann Arbor, MI, USA
1 shared publication Jeffrey W. Keister
Photon Sciences, Brookhaven National Laboratory, Upton, NY 11973, USA
1 shared publication- Jen Bohon
Case Center for Synchrotron Biosciences, Center for Proteomics and Bioinformatics, Case Western Reserve University, Cleveland, OH, USA
1 shared publication
Latest Publications
- Open Access
- 10 August 2021
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 24 (8) , 082001
-band linac designIn order to explore physics in the EUV to soft x-ray region, we have designed a machine which is capable of accelerating a electron bunch to an energy of . The front end of the CLARA (Compact Linear Accelerator for Research and Applications) system at Daresbury Labs will be used as an S-band injector of , sub-ps FWHM, electron bunches into the XARA (X-Band Accelerator for Research and Application) system. A rf feasibility study has been carried out for a structure operating in the mode at a frequency of 11.9942 GHz which is fed by a SLED klyston setup. The average cell of this structure has an iris radius of and a shunt impedance of . A high target gradient of for a single-bunch operation of the linac is necessary due to spatial constraints at Daresbury Labs. We have also implemented Gaussian detuning of the linac in order to future-proof the project for potential multibunch operation of the machine. After combining the rf study with an analysis of the uncoupled long-range wakefield and the short-range transverse wakefields, the optimal structure parameters are outlined as a compromise between the shunt impedance, electrical breakdown rate and wakefields in the structure. As novel designs will be tested using this free-electron laser (FEL) an increased beam charge may be useful. Therefore a beam dynamics study via the particle tracking code elegant has been performed to assess how the beam quality evolves while traveling through the XARA rf structures for different bunch charges and beam offsets. These simulations reveal how the bunch is disturbed for varying bunch charges and offsets and give an initial indication of how sensitive the beam parameters (beam centroid position, emittance, RMS beam size, etc.) are to the wakefields generated in XARA. An analytical formulation of the beam motion as it travels through the XARA linac has been utilized to calculate the emittance growth. This allows for comparison between analytical and numerical simulation of the beam dynamics to give confidence in the results. The beam dynamics study shows that for a bunch charge of and a beam offset of , the normalized emittance growth at the end of the XARA linac is . This may be mitigated by the design of a magnetic lattice which would include kickers to recenter the beam on the electrical axis of the structure, reducing the effect of the wakefields on the bunch. Currently it is probable that a maximum bunch charge of will be utilized for this machine; however a future design of a magnetic focusing lattice may allow higher charges to be viable and will reduce the emittance growth.- 10 August 2021
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 24 (8) , 082001
Open Access-band linac designIn order to explore physics in the EUV to soft x-ray region, we have designed a machine which is capable of accelerating a electron bunch to an energy of . The front end of the CLARA (Compact Linear Accelerator for Research and Applications) system at Daresbury Labs will be used as an S-band injector of , sub-ps FWHM, electron bunches into the XARA (X-Band Accelerator for Research and Application) system. A rf feasibility study has been carried out for a structure operating in the mode at a frequency of 11.9942 GHz which is fed by a SLED klyston setup. The average cell of this structure has an iris radius of and a shunt impedance of . A high target gradient of for a single-bunch operation of the linac is necessary due to spatial constraints at Daresbury Labs. We have also implemented Gaussian detuning of the linac in order to future-proof the project for potential multibunch operation of the machine. After combining the rf study with an analysis of the uncoupled long-range wakefield and the short-range transverse wakefields, the optimal structure parameters are outlined as a compromise between the shunt impedance, electrical breakdown rate and wakefields in the structure. As novel designs will be tested using this free-electron laser (FEL) an increased beam charge may be useful. Therefore a beam dynamics study via the particle tracking code elegant has been performed to assess how the beam quality evolves while traveling through the XARA rf structures for different bunch charges and beam offsets. These simulations reveal how the bunch is disturbed for varying bunch charges and offsets and give an initial indication of how sensitive the beam parameters (beam centroid position, emittance, RMS beam size, etc.) are to the wakefields generated in XARA. An analytical formulation of the beam motion as it travels through the XARA linac has been utilized to calculate the emittance growth. This allows for comparison between analytical and numerical simulation of the beam dynamics to give confidence in the results. The beam dynamics study shows that for a bunch charge of and a beam offset of , the normalized emittance growth at the end of the XARA linac is . This may be mitigated by the design of a magnetic lattice which would include kickers to recenter the beam on the electrical axis of the structure, reducing the effect of the wakefields on the bunch. Currently it is probable that a maximum bunch charge of will be utilized for this machine; however a future design of a magnetic focusing lattice may allow higher charges to be viable and will reduce the emittance growth. - Open Access
- 17 March 2012
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 19 (3) , 381-387
Transmission-mode diamond white-beam position monitor at NSLS
Two transmission-mode diamond X-ray beam position monitors installed at National Synchrotron Light Source (NSLS) beamline X25 are described. Each diamond beam position monitor is constructed around two horizontally tiled electronic-grade (p.p.b. nitrogen impurity) single-crystal (001) CVD synthetic diamonds. The position, angle and flux of the white X-ray beam can be monitored in real time with a position resolution of 500 nm in the horizontal direction and 100 nm in the vertical direction for a 3 mm × 1 mm beam. The first diamond beam position monitor has been in operation in the white beam for more than one year without any observable degradation in performance. The installation of a second, more compact, diamond beam position monitor followed about six months later, adding the ability to measure the angular trajectory of the photon beam.
- 17 March 2012
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 19 (3) , 381-387
Open AccessTransmission-mode diamond white-beam position monitor at NSLS
Two transmission-mode diamond X-ray beam position monitors installed at National Synchrotron Light Source (NSLS) beamline X25 are described. Each diamond beam position monitor is constructed around two horizontally tiled electronic-grade (p.p.b. nitrogen impurity) single-crystal (001) CVD synthetic diamonds. The position, angle and flux of the white X-ray beam can be monitored in real time with a position resolution of 500 nm in the horizontal direction and 100 nm in the vertical direction for a 3 mm × 1 mm beam. The first diamond beam position monitor has been in operation in the white beam for more than one year without any observable degradation in performance. The installation of a second, more compact, diamond beam position monitor followed about six months later, adding the ability to measure the angular trajectory of the photon beam.