GBGretchen H. Baker

Gretchen H. Baker

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gretchen H. Baker has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of appropriate restraint use on pediatric injury outcomes in motor vehicle crashes from US Trauma Quality Program data

    by Gretchen H. Baker, Angela L. Harden, Mary E. Cole, Julie A. Mansfield

    Motor vehicle crashes (MVCs) remained the second leading cause of death for children 5–9 yr and the third-leading cause of death for children 1–4 yr and 10–14 yr in the United States (US) in 2023 (...

  • Open Access

    Drivers of booster seat use and non-use among caregivers in the United States

    by Julie A. Mansfield, Gretchen H. Baker, Cassandra L. Herring, J. Morag MacKay


  • Open Access

    Numeracy and format influences comprehension of car seat recommendations

    by Brittany Shoots-Reinhard, Julie A. Mansfield, Maya Nintcheff, Ujin Bayarbadrakh, Gretchen H. Baker

  • Open Access

    Seat belt tension in child restraint system (CRS) installations with and without belt tensioning and lock-off features

    by Julie A. Mansfield, Rosalie R. Connell, Gretchen H. Baker

    Child restraint systems (CRS) are installed too loosely in 44-58% of vehicles, which increases injury risk. Some CRS include seat belt tensioning and lock-off features-typically a built-in clasp that clamps over the seat belt to produce tension with a mechanical advantage and/or lock the belt into place within the CRS shell. The objectives of this study are to define (1) how much belt tension can be produced across a variety of CRS designs with belt tensioning and lock-off features, and (2) how these features affect consumer misuse and opinions. The outboard seat belt anchor of a second row minivan seat was replaced with a tension load cell. For Aim 1, a convenience sample of 29 CRS was installed in the instrumented vehicle seat by a researcher. Before engaging the lock-off, the tension in the belt was pulled by hand to "pre-locked" tensions of either 2, 10, 20, 30, 40, 50, or 60 N. After engaging the lock-off, the "locked tension" in the belt was recorded. Then weighted plates were placed in the CRS to represent typical occupant masses and the locked belt tensions were recorded again. For Aim 2, 30 adult participants installed a subset of four CRS into the instrumented vehicle seat. Three CRS included a lock-off (two rear-facing only (RFO) infant bases and one forward-facing convertible) and one CRS did not include a lock-off (RFO infant base). Belt tensions and installation errors were compared across CRS and participant feedback was collected via survey. Seven lock-off designs did not create additional belt tension while the others produced tensions that were three to 10 times greater than the Federal Motor Vehicle Safety Standard (FMVSS) 213 testing range of 53.5-67.0 N. Adding occupant mass to the installations reduced the locked belt tensions by approximately 21, 40, and 61 N for the masses of the CRABI 12 mo, HIII 3yo, and HIII 6yo, respectively. For the participant installations, CRS with belt tensioning lock-offs had significantly higher tension levels (66.5 ± 25.1 and 66.2 ± 35.9 N) compared to a lock-off design which simply locked the belt in place (32.8 ± 24.8 N) and the CRS without a lock-off (18.6 ± 15.1 N) (p < 0.05). Before engaging the lock-off, participants pulled on the belt with averages of 9.4 and 29.7 N of tension for each of the two RFO CRS but very little tension (∼ 0 N) for the forward-facing CRS. Errors of incorrect belt path and incorrect lock-off use were noted for several participants. CRS belt lock-offs, especially those that produce additional tension, help consumers achieve tight installations. However, manufacturers' instructions should be sure to address common misuse scenarios which may be introduced by lock-offs.


  • Are child and teenage occupants appropriately restrained while travelling in rideshare vehicles?

    by S. Koppel, F. Kaviani, B. Albanese, J. Mansfield, G.H. Baker, R. Connell, E.B. Sartin, K.B. Arbogast, B. Shannon, J.P. Ehsani, et al.


  • Open Access

    Influence of initial belt torso contact on the kinematics and kinetics of booster-seated ATDs in frontal-oblique impacts

    by Gretchen H. Baker, Julie A. Mansfield, John H. Bolte

    Varying initial belt torso contact (i.e., belt gap) on belt-positioning boosters may have implications for potential shoulder belt slip-off in low-speed evasive vehicle maneuvers and differences in dynamic outcomes in frontal sled tests. This study evaluated the influence of initial booster belt gap and belt fit conditions on the kinematic and kinetic outcomes during frontal oblique impacts. Frontal oblique (+15° from frontal) sled tests (n = 18; 23.6 ± 0.1 g at 12.4 ± 0.1 ms) were conducted using the Q-Series 6-year-old (Q6) and 10-year-old (Q10) and the Large Omni Directional Child (LODC) anthropomorphic test devices (ATDs). Various initial belt fit and belt gap conditions were investigated by evaluating each ATD on 2 high-back (HB), 3 low-back (LB), and 1 low-profile (Low) booster. Initial belt fit and belt gap were quantified, and boosters were categorized as "smaller gap" or "larger gap" for comparison. Larger-gap boosters produced greater peak lumbar FY and MZ (HB: -23.2 ± 8.8 Nm, LB: -23.6 ± 9.7 Nm) compared to smaller-gap boosters (HB: -12.6 ± 4.4 Nm, LB/Low: -12.4 ± 7.2 Nm) for the LODC and Q10. Peak axial torso rotations were also observed for larger-gap LB (38.6°) compared to smaller-gap LB boosters (23.8°), and the LODC experienced greater peak thoracic rotations on larger-gap boosters compared to smaller-gap boosters. These results suggest that ATDs on larger-gap boosters experienced greater torso rotation and lumbar MZ due to lack of initial contact between the shoulder belt and inferior torso. No ATDs experienced complete shoulder belt slip-off; however, larger-gap boosters displayed more visual evidence of outboard shoulder belt positioning at the time of peak forward head excursion. This study provides a novel investigation on the role of initial belt fit and belt gap metrics on the dynamic response of booster-seated ATDs in frontal oblique impacts. Larger-gap boosters allowed the torso to undergo greater axial rotation before restraint was provided by the shoulder belt to the lower torso. Increased shoulder rotations may indicate greater propensity for shoulder belt slip-off in more severe crashes, in oblique maneuvers, or with variations in initial occupant posture. These results suggest the importance of continued evaluation of the implications of initial belt gap provided by boosters and the importance of evaluating lumbar FY and MZ and useful metrics for discrimination of differences in ATD response across booster designs.


  • Open Access

    Thoracic responses and injuries to male postmortem human subjects (PMHS) in rear-facing seat configurations in high-speed frontal impacts

    by Yun-Seok Kang, Jason Stammen, Amanda M. Agnew, Gretchen H. Baker, Vikram Pradhan, Alexander Bendig, Alena Hagedorn, Kevin Moorhouse, John H. Bolte Iv

    Objective: One potential nonstandard seating configuration for vehicles with automated driving systems (ADS) is a reclined seat that is rear-facing when in a frontal collision. There are limited biomechanical response and injury data for this seating configuration during high-speed collisions. The main objective of this study was to investigate thoracic biomechanical responses and injuries to male postmortem human subjects (PMHS) in a rear-facing scenario with varying boundary conditions.Method: Fourteen rear-facing male PMHS tests (10 previously published and 4 newly tested) were conducted at two different recline angles (25-degree and 45-degree) in 56 km/h frontal impacts. PMHS were seated in two different seats; one used a Fixed D-Ring (FDR) seat belt assembly and one used an All Belts To Seat (ABTS) restraint. For thoracic instrumentation, strain gages were attached to ribs to quantify strain and fracture timing. A chestband was installed at the mid-sternum level to quantify anterior-posterior (AP) chest deflections. Data from the thorax instrumentation were analyzed to investigate injury mechanisms.Results: The PMHS sustained a greater number of rib fractures (NRF) in the 45-degree recline condition (12 ± 7 NRF for ABTS45 and 25 ± 18 NRF for FDR45) than the 25-degree condition (6 ± 4 NRF for ABTS25 and 12 ± 8 NRF for FDR25), despite AP chest compressions in the 45-degree condition (-23.7 ± 9.4 mm for ABTS45 and -39.6 ± 11.9 mm for FDR45) being smaller than the 25-degree condition (-38.9 ± 16.9 mm for ABTS25 and -55.0 ± 4.4 mm for FDR25). The rib fractures from the ABTS condition were not as symmetric as the FDR condition in the 25-degree recline angle due to a belt retractor structure located at one side of the seatback frame. Average peak AP chest compression occurred at 45.7 ± 3.4 ms for ABTS45, 45.6 ± 3.1 ms for FDR45, 46.7 ± 1.9 ms for ABTS25, and 46.9 ± 2.3 ms for FDR25. Average peak seatback resultant force occurred at 43.9 ± 0.9 ms for ABTS45, 44.6 ± 0.8 ms for FDR45, 42.5 ± 0.2 ms for ABTS25, and 41.5 ± 0.5 ms for FDR25. The majority of rib fractures occurred after peak AP chest compression and peak seatback resultant force likely due to the ramping motion of the PMHS, which might create a combined loading (e.g., AP deflection and upward deflection) to the thorax. Although NRF in the 45-degree reclined condition was greater than the 25-degree recline condition, similar magnitudes of rib strains were observed regardless of seat and restraint types, while strain modes varied.Conclusions: The majority of rib fractures occurred after peak AP chest compression and peak seatback force, especially in FDR25, ABTS45, and FDR45, while the PMHS ramped up along the seatback. AP chest compression, seatback load, and strain measured along the rib could not explain the greater NRF in the 45-degree recline conditions. A complex combination of AP chest deflection with upward deflection was discovered as a possible mechanism for rib fractures in PMHS subjected to rear-facing frontal impacts in this study.


  • Open Access

    Evaluation of static belt fit and belt torso contact for children on belt-positioning booster seats

    by Gretchen H. Baker, Julie A. Mansfield, Randee L. Hunter, John H. Bolte

    Objective: Previous studies have indicated that gap between the seatbelt and torso (reduced belt torso contact) for children on belt-positioning booster seats (BPBs) may lead to less torso engagement and increased likelihood of shoulder belt slip-off during evasive vehicle maneuvers, potentially increasing injury risk during crashes. However, current BPB belt fit measures do not quantify belt gap and may not be able to fully discriminate between designs which provide good vs. poor dynamic outcomes. The goal of this study was to evaluate both novel (belt gap characteristics) and conventional measures of seatbelt fit for BPB-seated children. Methods: Ten BPBs and three seatbelt anchor locations were investigated. Fifty volunteers (4-14 years) were recruited and each evaluated on six unique combinations of BPB and seatbelt anchor location on a vehicle rear seat in a laboratory setting. A 3 D coordinate measurement system quantified positions of anatomic, seatbelt, BPB, and vehicle reference points. Novel belt gap (gap size, length, location, and percent torso contact) and conventional belt fit (position of belt on shoulder and pelvis) metrics were calculated using anatomic and seatbelt landmarks. Variation in belt fit and belt gap outcomes due to BPB, seatbelt anchor location, and anthropometry were investigated. Results: BPBs produced significantly different outcomes, while seatbelt anchor location did not. BPBs with features that directly routed the lower portion of the shoulder belt more forward on the buckle side produced the largest (29.3 ± 12.6 mm) and longest (106.9 ± 68.2 mm) belt gap on average, while BPBs that pulled the belt less forward or did not directly route the belt produced the smallest (13.9 ± 6.7 mm) and shortest (16.9 ± 33.9 mm) gap on average. Belt gap outcomes were not strongly correlated with conventional belt fit metrics, indicating that evaluation of belt gap may provide additional insight when attempting to discriminate between BPBs which provide good vs. poor seatbelt engagement during vehicle maneuvers and crashes. Conclusions: This is the first study to evaluate belt gap characteristics for BPB-seated children. Results suggest that belt fit and belt gap are influenced by BPB design, particularly lower shoulder belt routings, and may have implications for belt engagement during dynamic events.