NZNicolas Zabler

Nicolas Zabler

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nicolas Zabler has a total of 87 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Epileptic arousals: A neglected clinical entity

    by Lea Fisel, Nóra Pető, Sotirios Kalousios, Nicolas Zabler, Armin Brandt, Peter C. Reinacher, Dieter Riemann, Mohammad F. Khazali, Andreas Schulze‐Bonhage

    Objective: Epileptic arousals (EAs) are seizures characterized solely by arousal from sleep. EAs are unrecognized in current seizure classifications. Their subtle semiology and inconsistently detectable ictal activity in scalp electroencephalography (EEG) complicate differentiation from physiological arousals (PAs). This study characterizes EAs using simultaneous intracranial electroencephalography (iEEG) and scalp EEG with electrocardiography (ECG), exploring their neural and autonomic dynamics. Methods: We retrospectively analyzed presurgical video‐EEG monitoring data of 20 focal epilepsy patients (2010–2023). EAs were identified visually. Their seizure‐onset zones (SOZs) and seizure‐propagation zones (SPZs) were defined in Montreal Neurological Institute (MNI) space and compared to other seizure types. The detectability of ictal activity of EAs in scalp EEG was evaluated. Associations with SOZs/SPZs were assessed using logistic regression. Heart rate dynamics were compared between EAs and PAs evaluating distribution modality, variability, and receiver operating characteristic (ROC) analysis. Results: Among 507 seizures, 133 (26.2%) were EAs. SOZs of EAs partially overlapped with other seizure types (Jaccard similarity index 0.47). Two‐thirds (66.9%) of EAs were undetectable by scalp EEG. Detectability increased with broader maximal SPZs (odds ratio [OR] = 3.16; ROC‐AUC [area under the curve] = 0.891). Heart rate increased during both EAs and PAs ( p < 0.001), yet modulation was greater during EAs ( p = 0.007, ROC‐AUC = 0.995) and showed a multimodal distribution ( p < 0.001). Significance: EAs are common, yet underrecognized. They arise from partially distinct networks and may exhibit a specific autonomic signature, supporting their recognition as a separate seizure type. Reliance on scalp EEG alone risks missing patients with a high EA burden. Undetected EAs can perpetuate epileptic activity and sleep fragmentation.

  • Open Access

    Exploring associations between ambient temperatures and seizure occurrence

    by David Gromes, Nicolas Zabler, Nur Qasrina Binte Mohamed Shafei, Christian Goelz, Marco Dallavalle, Nikolaos Nikolaou, Matthias Dümpelmann, Tobias Loddenkemper, Andreas Schulze-Bonhage, Alexandra Schneider, et al.

  • Open Access

    A multicenter, video‐ EEG ‐based validation of a multimodal wearable device for focal seizure detection in adults: The SeizeIT2 study

    by Lauren Swinnen, Miguel Bhagubai, Christos Chatzichristos, Yvonne Weber, Stefan Wolking, Ummehan Ermis, Elisabeth Schriewer, Andreas Schulze‐Bonhage, Matthias Dümpelmann, Nicolas Zabler, et al.

    Objective: Currently available wearable devices for detecting focal seizures primarily target major motor seizures or involve semi‐invasive subscalp implants. There is a pressing need for accurate, non‐invasive methods to detect diverse focal seizures for long‐term, out‐of‐hospital monitoring. Methods: In this multicenter study (SeizeIT2), people with refractory focal epilepsy undergoing long‐term video‐electroencephalography (EEG) monitoring were simultaneously recorded with the Sensor Dot, a multimodal wearable device using EEG and electrocardiography (ECG). Wearable recordings were first processed with an offline detection algorithm, after which the algorithm‐labeled segments underwent blinded review by a human expert, and results were compared with ground truth video‐EEG. Post‐hoc analyses were performed to evaluate how specific seizure characteristics, defined by the gold‐standard recordings, influenced detection sensitivity. Results: We recruited 192 adult participants, documenting a total of 616 focal seizures. The mean duration of Sensor Dot monitoring was 5 days. The seizure detection algorithm achieved an overall sensitivity of 0.73, precision of 0.004 and F1 score of 0.01. Following human review, a precision of 0.83 was achieved, albeit with a sensitivity of 0.31, resulting in an F1 score of 0.45. Seizure detection was influenced by the seizure type (focal impaired awareness seizure (FIAS) or focal‐to‐bilateral tonic–clonic seizures (FBTCS)) and the presence of a distinct ictal pattern on behind‐the‐ear EEG, constituting mostly temporal lobe seizures. In a post‐hoc subgroup analysis of seizures with a clear ictal EEG pattern and ictal tachycardia (as determined by the ground truth), a sensitivity of 0.74 was observed, whereas a sensitivity of 0.60 was achieved when there was visible electrographic seizure activity without tachycardia. Significance: The overall performance of the Sensor Dot in focal seizure detection was limited in an unselected group of focal seizure types. Our findings suggest that the proposed approach, combining algorithm‐based detection with human review, provides detection performance comparable with diary self‐reporting, in terms of sensitivity, but with higher precision (0.83 vs. 0.60). Our findings suggest that this multimodal approach may be particularly beneficial for the subset of patients whose seizures are characterized by distinct ictal EEG patterns and tachycardia—features frequently seen in temporal lobe epilepsy. However, the prospective utility of these markers for patient selection requires further validation. Plain Language Summary: Wearable devices may help improve seizure detection in people with epilepsy, but few non‐invasive options exist for detecting focal seizures. We studied a behind‐the‐ear wearable device (Sensor Dot) using automated analysis combined with expert review. Overall, this approach resulted in detection of seizures with low sensitivity but high precision. Post‐hoc subgroup analysis suggested that for seizures characterized by a distinct ictal EEG pattern and tachycardia—features often seen in temporal lobe epilepsy—this multimodal approach achieved a sensitivity of 0.74. Further prospective validation is required to confirm if this performance can be replicated through pre‐monitoring patient selection.


  • Open Access

    Clinical utility of an ambulatory absence seizure detection system

    by Nicolas Zabler, Andrea Biondi, Sotirios Kalousios, Yulia Novitskaya, Hans Faber, Matthias Dümpelmann, Andreas Schulze‐Bonhage, Martin Hirsch

    Novel absence seizure detection systems have emerged in recent years, showing consistent results in ambulatory monitoring. This study aimed to provide real‐world evidence of how these systems support clinical decision‐making. At the Freiburg Epilepsy Center, 16 patients diagnosed with genetic generalized epilepsy were provided with a human‐driven, AI‐assisted electrographic absence seizure detection service utilizing a wearable EEG device during a three‐day ambulatory monitoring period. We retrospectively analyzed and categorized therapeutic decisions made by neurologists based on their interpretation of the service's results in the context of routine clinical care. Electrographic seizure frequency and mean seizure duration were compared based on whether an intervention in treatment or care management was performed. Additionally, we assessed patients' self‐reporting performance and compared agreement between seizure activity reported by patients and that recorded by the service. Electrographic absence seizure patterns were observed in 12 patients, with a total of 459 events recorded. Agreement with seizure diary data was low (Cohen's κ = 0.14). The data obtained influenced neurologists' decisions on confirming therapeutic success, adjusting treatment plans, recommending inpatient video‐EEG monitoring, and performing differential diagnostic evaluations. Patients with an intervention exhibited higher electrographic seizure frequencies and longer mean seizure durations. The results underscore the technology's potential in supporting clinical decisions by enhancing the clinical picture. Plain Language Summary: We used a wearable EEG device to quantify absence seizures in people with epilepsy during everyday activities. The system helped neurologists to identify and assess seizure activity objectively. Our findings show that this can support treatment decisions, highlighting the potential to improve clinical care.


  • Open Access

    The impact of EEG preprocessing parameters on ultra‐low‐power seizure detection

    by Patrick Reisinger, Jonathan Larochelle, Ciamak Abkai, Sotirios Kalousios, Nico Zabler, Matthias Dümpelmann, Andreas Schulze‐Bonhage, Peter Woias, Laura Comella

    Objective: Closed‐loop neurostimulation is a promising treatment for drug‐resistant focal epilepsy. A major challenge is fast and reliable seizure detection via electroencephalography (EEG). Although many approaches have been published, they often lack statistical power and practical utility. The use of various EEG preprocessing parameters and performance metrics hampers comparability. Additionally, the critical issue of energy consumption for an application in medical devices is rarely considered. Addressing these points, we present a systematic analysis of the impact of EEG preprocessing parameters on seizure detection performance and energy consumption, using one to four EEG channels. Methods: We analyzed in 145 patients with focal epilepsy the impact of different sampling rates, window sizes, digital resolutions, and number of EEG channels on seizure detection performance and energy consumption. Focusing on clinically relevant, event‐based metrics, we evaluated seizure detection performance of a state‐of‐the‐art convolutional neural network (CNN) via the Seizure Community Open‐Source Research Evaluation (SzCORE) framework. Statistical relevance of parameter changes was assessed using linear mixed‐effects models. Energy consumption was analyzed using an ultra‐low‐power microcontroller. Results: Reducing the sampling rate from 256 to 64 Hz decreased sensitivity ( p = .015) and false detections per hour (FD/h; p = .002). Larger windows reduced FD/h between 1 s and all other sizes (all p < .001). Lower digital resolution decreased sensitivity between 16 and 8 bits ( p = .007). Using one EEG channel instead of four decreased sensitivity ( p < .001) and increased detection delay ( p = .020), but also reduced FD/h ( p = .005). Reducing the sampling rate to 64 Hz lowered CNN energy consumption from 49.15 to 17.26 μJ/s, and using one channel reduced it from 79.04 to 31.63 μJ/s. Significance: This study provides guidance on choosing EEG preprocessing parameters for innovative developments of closed‐loop neurostimulation devices to further advance the treatment of drug‐resistant focal epilepsy.


  • Open Access

    Memory optimized random forest classifier for EEG seizure detection in implantable monitoring and closed-loop neurostimulation devices

    by Sotirios Kalousios, Jonathan Larochelle, Nicolas Zabler, Nico Locker, Peter Woias, Laura Maria Comella, Andreas Schulze-Bonhage, Matthias Dümpelmann

    Objective. Up to one third of epilepsy patients do not achieve satisfactory seizure control and may benefit from implantable devices for responsive neurostimulation or online seizure monitoring. Beyond energy efficiency, the limited memory capacity in these devices, imposes significant constraints to algorithmic design of seizure detection models. This study aims to evaluate the performance of cross-patient random forest (RF) models optimized for low-power microcontroller applications by assessing various channel integration strategies and measuring their memory requirements. Approach. Fifty patients undergoing electroencephalographic monitoring with 362 seizures were included in the analysis, with approximately one hour of signal for each seizure. One central and four peripheral electrodes over the epileptogenic focus were selected to resemble the layout of a novel neurostimulation device. Fifteen features were extracted from 2 s non-overlapping segments. RF models comprised either 500 or 125 trees, with varying depths. Three early channel integration (EI) strategies were compared with late integration (LI), using three channel fusion methods. A leave-one-patient-out cross-validation approach was used for evaluation, and memory requirements, alongside with inference energy and latency for 8-bit integer and 32-bit floating point models were computed on a microcontroller. Main results. The performance of EI feature sorting and LI were comparable. LI was favored by the 32-bit floating point format and more complex models, with the median channel fusion achieving a median area under the receiver operating characteristic curve score of 0.925. Feature sorting performed best with medium-sized models and was largely unaffected by the 8-bit integer format. Following causal output post-processing, false stimulations per hour were reduced to 5.5 at 100% sensitivity and fell below 3 at ∼ 80% sensitivity. Significance. Our findings suggest that RF models with minimal energy and memory requirements can achieve state-of-the-art performance, making them well-suited for embedded applications in implantable devices. The complex interplay of the investigated factors is critical to performance, and along hardware specifications, should guide algorithmic design.


  • Long-Term Adherence to a Subcutaneous Two-Channel EEG System in Patients With Focal Epilepsy

    by Nicolas Msc Zabler, Yulia Novitskaya, René Bsc Sprünken, Martin Hirsch, Matthias Dümpelmann, Andreas Schulze-Bonhage

    Purpose: Outpatient seizure monitoring is crucial for optimizing treatment strategies in epilepsy; however, traditional approaches such as seizure diaries and wearables have limitations in accuracy and practicality. This study evaluated the adherence and utility of an implanted subcutaneous EEG monitoring system in patients with focal temporal lobe epilepsy. Methods: At a tertiary epilepsy center, patients with focal epilepsy received a subcutaneous two-channel EEG system for ultra-long-term monitoring. The system includes a subcutaneously implanted electrode for data recording and a behind-the-ear companion device for the power supply and data transmission. Patient adherence to the device was evaluated using generalized estimating equations, considering sex, daytime/nighttime periods, age, and temporal course of measurements. The correlations between adherence and electrographic or diary-recorded seizures were also assessed. Results: Fifteen adult patients (mean age: 45.6 years, 6 females) were monitored for an average of 200.6 days, with 416 electrographic seizures confirmed in 13 patients. The median adherence was 89.3% (interquartile range, [75.6%, 93.4%]), with females showing significantly higher adherence than males ( β , −1.1600; P = 0.049). Seizure diary reporting sensitivity and precision were 20.8% and 56.4%, respectively, compared with confirmed electrographic seizures. Adherence correlated positively with confirmed electrographic seizures ( r , 0.40; P, 0.004), but not with diary reports ( r , −0.22; P, 0.13). Conclusions: Patients using the subcutaneous EEG system demonstrated high adherence and reliable seizure monitoring, suggesting that it could serve as a valuable tool for managing focal epilepsy in clinical practice.


  • Open Access

    The impact of EEG preprocessing parameters on ultra-low-power seizure detection

    by Patrick Reisinger, Jonathan Larochelle, Ciamak Abkai, Sotirios Kalousios, Nico Zabler, Matthias Duempelmann, Andreas Schulze-Bonhage, Peter Woias, Laura Comella

    Objective: Closed-loop neurostimulation is a promising treatment for drug-resistant focal epilepsy. A major challenge is fast and reliable seizure detection via electroencephalography (EEG). While many approaches have been published, they often lack statistical power and practical utility. The use of various EEG preprocessing parameters and performance metrics hampers comparability. Additionally, the critical issue of energy consumption for an application in medical devices is rarely considered. Addressing these points, we present a systematic analysis on the impact of EEG preprocessing parameters on seizure detection performance and energy consumption, using one to four EEG channels. Methods: We analyzed in 145 patients with focal epilepsy the impact of different sampling rates, window sizes, digital resolutions and number of EEG channels on seizure detection performance and energy consumption. Focusing on clinically relevant, event-based metrics, we evaluated seizure detection performance of a state-of-the-art convolutional neural network (CNN) via the Seizure Community Open-Source Research Evaluation (SzCORE) framework. Statistical relevance of parameter changes was assessed using linear mixed-effects models. Energy consumption was analyzed using an ultra-low-power microcontroller. Results: Reducing the sampling rate from 256 to 64 Hz led to a decrease in sensitivity ( p = .015) and false detections per hour (FD/h; p = .002). Larger window sizes reduced sensitivity between 1 and 8 second windows ( p = .033) and FD/h between one second and all other sizes (all p values < .001). Average detection delays increased between one second and 4 and 8 second windows (both p < .01). Lower digital resolutions decreased sensitivity between 16 and 8 bits ( p = .007). Compared to four channels, using only one EEG channel resulted in a decrease in sensitivity ( p < .001) and an increase in the average detection delay ( p = .020), but showed less FD/h ( p = .005). CNN energy consumption decreased from 49.15 to 17.26 µJ/s when the sampling rate was reduced from 256 to 64 Hz. Lowering the number of channels from four to one reduced the CNN energy consumption from 79.04 to 31.63 µJ/s. Significance: This study provides guidance on choosing EEG preprocessing parameters for innovative developments of closed-loop neurostimulation devices to further advance the treatment of drug-resistant focal epilepsy. Key points: A major challenge in closed-loop neurostimulation is fast and reliable seizure detection, ideally with minimal energy consumption. Many published seizure detection approaches are not ready for application and lack statistical power and comparability. The impact of EEG preprocessing parameters was systematically evaluated in 145 patients with focal epilepsy. The chosen window size and number of channels had the strongest impact on seizure detection performance and energy consumption. Our results offer guidance for EEG preprocessing choices to advance the treatment of drug-resistant focal epilepsy.


  • Open Access

    The value of self-reported variables in epilepsy monitoring and management. A systematic scoping review

    by Andrea Biondi, Nicolas Zabler, Sotirios Kalousios, Sara Simblett, Petroula Laiou, Pedro F. Viana, Matthias Dümpelmann, Andreas Schulze-Bonhage, Mark P. Richardson


  • Open Access

    Effects of epileptic seizures on the quality of biosignals recorded from wearables

    by Sebastian Böttcher, Nicolas Zabler, Michele Jackson, Elisa Bruno, Andrea Biondi, Nino Epitashvili, Solveig Vieluf, Matthias Dümpelmann, Mark P. Richardson, Benjamin H. Brinkmann, et al.

    Objective: Wearable nonelectroencephalographic biosignal recordings captured from the wrist offer enormous potential for seizure monitoring. However, signal quality remains a challenging factor affecting data reliability. Models trained for seizure detection depend on the quality of recordings in peri‐ictal periods in performing a feature‐based separation of ictal periods from interictal periods. Thus, this study aims to investigate the effect of epileptic seizures on signal quality, ensuring accurate and reliable monitoring.Methods: This study assesses the signal quality of wearable data during peri‐ictal phases of generalized tonic–clonic and focal to bilateral tonic–clonic seizures (TCS), focal motor seizures (FMS), and focal nonmotor seizures (FNMS). We evaluated accelerometer (ACC) activity and the signal quality of electrodermal activity (EDA) and blood volume pulse (BVP) data. Additionally, we analyzed the influence of peri‐ictal movements as assessed by ACC (ACC activity) on signal quality and examined intraictal subphases of focal to bilateral TCS.Results: We analyzed 386 seizures from 111 individuals in three international epilepsy monitoring units. BVP signal quality and ACC activity levels differed between all seizure types. We found the largest decrease in BVP signal quality and increase in ACC activity when comparing the ictal phase to the pre‐ and postictal phases for TCS. Additionally, ACC activity was strongly negatively correlated with BVP signal quality for TCS and FMS, and weakly for FNMS. Intraictal analysis revealed that tonic and clonic subphases have the lowest BVP signal quality and the highest ACC activity.Significance: Motor elements of seizures significantly impair BVP signal quality, but do not have significant effect on EDA signal quality, as assessed by wrist‐worn wearables. The results underscore the importance of signal quality assessment methods and careful selection of robust modalities to ensure reliable seizure detection. Future research is needed to explain whether seizure detection models' decisions are based on signal responses induced by physiological processes as opposed to artifacts.