The impact of EEG preprocessing parameters on ultra‐low‐power seizure detection
Authors:
- Patrick ReisingerPRPatrick Reisinger
- Jonathan LarochelleJLJonathan Larochelle
- Ciamak AbkaiCACiamak Abkai
- Sotirios KalousiosSKSotirios Kalousios
- Nico ZablerNZNico Zabler
- Matthias DümpelmannMDMatthias Dümpelmann
- Andreas Schulze‐BonhageASAndreas Schulze‐Bonhage
- Peter WoiasPWPeter Woias
- Laura ComellaLCLaura Comella
Open Access
Abstract
Objective: Closed‐loop neurostimulation is a promising treatment for drug‐resistant focal epilepsy. A major challenge is fast and reliable seizure detection via electroencephalography (EEG). Although many approaches have been published, they often lack statistical power and practical utility. The use of various EEG preprocessing parameters and performance metrics hampers comparability. Additionally, the critical issue of energy consumption for an application in medical devices is rarely considered. Addressing these points, we present a systematic analysis of the impact of EEG preprocessing parameters on seizure detection performance and energy consumption, using one to four EEG channels. Methods: We analyzed in 145 patients with focal epilepsy the impact of different sampling rates, window sizes, digital resolutions, and number of EEG channels on seizure detection performance and energy consumption. Focusing on clinically relevant, event‐based metrics, we evaluated seizure detection performance of a state‐of‐the‐art convolutional neural network (CNN) via the Seizure Community Open‐Source Research Evaluation (SzCORE) framework. Statistical relevance of parameter changes was assessed using linear mixed‐effects models. Energy consumption was analyzed using an ultra‐low‐power microcontroller. Results: Reducing the sampling rate from 256 to 64 Hz decreased sensitivity ( p = .015) and false detections per hour (FD/h; p = .002). Larger windows reduced FD/h between 1 s and all other sizes (all p < .001). Lower digital resolution decreased sensitivity between 16 and 8 bits ( p = .007). Using one EEG channel instead of four decreased sensitivity ( p < .001) and increased detection delay ( p = .020), but also reduced FD/h ( p = .005). Reducing the sampling rate to 64 Hz lowered CNN energy consumption from 49.15 to 17.26 μJ/s, and using one channel reduced it from 79.04 to 31.63 μJ/s. Significance: This study provides guidance on choosing EEG preprocessing parameters for innovative developments of closed‐loop neurostimulation devices to further advance the treatment of drug‐resistant focal epilepsy.Keywords
All Related Versions
This publication has 53 references indexed in Scilit:
- Automated Interpretation of Clinical Electroencephalograms Using Artificial IntelligenceJAMA Neurology, 2023
- Focal Cortex Stimulation With a Novel Implantable Device and Antiseizure Outcomes in 2 Prospective Multicenter Single-Arm TrialsJAMA Neurology, 2023
- Focal epilepsies: Update on diagnosis and classificationEpileptic Disorders, 2023
- The burden of epilepsy and unmet need in people with focal seizuresBrain and Behavior, 2022
- Objective Evaluation Metrics for Automatic Classification of EEG Events2021
- Epileptic Seizure Detection Using Deep Recurrent Neural Networks in EEG Signals2020
- Pulse generator battery life in deep brain stimulation: out with the old… in with the less durable?Acta Neurochirurgica, 2019
- Which Reference Should We Use for EEG and ERP practice?Brain Topography, 2019
- Reconstruction of EEG from limited channel acquisition using estimated signal correlationBiomedical Signal Processing and Control, 2016
- Closed-loop Neurostimulation: The Clinical ExperienceNeurotherapeutics, 2014