Takuma Tomizawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Takuma Tomizawa has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Fanwei Yu
Department of Quantum Science and Energy Engineering, Graduate School of Engineering, Tohoku University, Sendai, Japan
3 shared publications Noritaka Yusa
Department of Quantum Science and Energy Engineering, Graduate School of Engineering, Tohoku University, Sendai, Miyagi, 980-8579, Japan
3 shared publications- Noritaka Yusa
Tohoku University
3 shared publications - Haicheng Song
Department of Quantum Science and Energy Engineering, Graduate School of Engineering, Tohoku University, Sendai, Japan
2 shared publications Hidetoshi Hashizume
2 shared publicationsAnish Poudel
1 shared publication
Latest Publications
- 27 August 2026
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
Evaluating the effect of error in thickness evaluation on the reliability of pipe remaining life prediction
Background: Accurately estimating the remaining life of pipes affected by wall thinning relies on ultrasonic testing (UT). However, unpredictable measurement errors can complicate these estimations, and assuming normally-distributed errors may not always be justified. Purpose: This study examines the impact of unpredicted UT measurement errors on pipe life estimation and explores suitable predictive models under realistic error assumptions. Methods: Thirty artificially corroded plate samples were tested using conventional UT with a 5 MHz transducer, conducted by an unqualified operator. The distribution of measurement errors was assessed. Simulations modeled annual UT measurements for a virtual pipe over ten years, predicting thickness in the 10 th year using either linear regression or Bayesian inference. Results: The analysis showed that the UT measurement errors did not follow a normal distribution, indicating limitations in using traditional statistical models. Simulations demonstrated that Bayesian inference consistently produced more reliable predictions of pipe thickness across different error models, outperforming conventional linear regression. Conclusion: Assuming normality in UT error distribution is not appropriate in all cases. Bayesian inference offers a more robust and reliable approach for predicting the remaining life of pipes under uncertain error conditions compared to conventional methods.
- 27 August 2026
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
Evaluating the effect of error in thickness evaluation on the reliability of pipe remaining life prediction
Background: Accurately estimating the remaining life of pipes affected by wall thinning relies on ultrasonic testing (UT). However, unpredictable measurement errors can complicate these estimations, and assuming normally-distributed errors may not always be justified. Purpose: This study examines the impact of unpredicted UT measurement errors on pipe life estimation and explores suitable predictive models under realistic error assumptions. Methods: Thirty artificially corroded plate samples were tested using conventional UT with a 5 MHz transducer, conducted by an unqualified operator. The distribution of measurement errors was assessed. Simulations modeled annual UT measurements for a virtual pipe over ten years, predicting thickness in the 10 th year using either linear regression or Bayesian inference. Results: The analysis showed that the UT measurement errors did not follow a normal distribution, indicating limitations in using traditional statistical models. Simulations demonstrated that Bayesian inference consistently produced more reliable predictions of pipe thickness across different error models, outperforming conventional linear regression. Conclusion: Assuming normality in UT error distribution is not appropriate in all cases. Bayesian inference offers a more robust and reliable approach for predicting the remaining life of pipes under uncertain error conditions compared to conventional methods.
- 14 August 2024
- Published by Elsevier in NDT & E International
- Vol. 147
Hybrid multi-modal NDE sensing system for in-motion detection and localization of rolling contact fatigue damage in rails
- 14 August 2024
- Published by Elsevier in NDT & E International
- Vol. 147
Hybrid multi-modal NDE sensing system for in-motion detection and localization of rolling contact fatigue damage in rails
- 12 April 2024
- Published by Elsevier in Fusion Engineering and Design
- Vol. 203
Signal-distribution-based crack detection for divertor monoblock inspection using eddy current testing
- 12 April 2024
- Published by Elsevier in Fusion Engineering and Design
- Vol. 203
Signal-distribution-based crack detection for divertor monoblock inspection using eddy current testing
- 20 November 2023
- Published by Elsevier in NDT & E International
- Vol. 141
Bayesian data fusion of eddy current testing for flaw characterization with uncertainty evaluation
- 20 November 2023
- Published by Elsevier in NDT & E International
- Vol. 141
Bayesian data fusion of eddy current testing for flaw characterization with uncertainty evaluation
- 30 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-10
Inspection of Pitting Corrosions on Weld Overlay Cladding Using Uniform and Rotating Eddy Current Testing
This study investigated the applicability of detecting pitting corrosions on stainless steel weld overlay cladding using uniform eddy current testing, which is insensitive to surface undulation, and rotating eddy current testing (RECT), which can be considered a superposition of uniform eddy current testing in orthogonal directions. The performance of the two techniques in detecting artificial pitting corrosions on and next to weld beads was compared. The signal distributions revealed that only RECT was capable of describing the surface profiles of pitting corrosions. The results of uniform eddy current testing could not distinguish between pitting corrosions and cracks. The probability of detection curves drawn to quantitatively indicate the detection capabilities of the two techniques revealed that uniform eddy current testing with induced eddy currents parallel and perpendicular to weld beads was better than RECT in detecting pitting corrosions on and next to weld beads, respectively. Scanning twice by uniform eddy current testing at orthogonal orientations may be a better process for detecting pitting corrosion on weld overlay cladding compared with using RECT. The measured signals of the two techniques in normal direction were located around the edges of the pitting corrosions, which only indicated the depth around edges. The results suggested that uniform eddy current testing and RECT with normal direction magnetic field signals may be inadequate for evaluating the maximum depth of pitting corrosions or large corrosions.
- 30 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-10
Inspection of Pitting Corrosions on Weld Overlay Cladding Using Uniform and Rotating Eddy Current Testing
This study investigated the applicability of detecting pitting corrosions on stainless steel weld overlay cladding using uniform eddy current testing, which is insensitive to surface undulation, and rotating eddy current testing (RECT), which can be considered a superposition of uniform eddy current testing in orthogonal directions. The performance of the two techniques in detecting artificial pitting corrosions on and next to weld beads was compared. The signal distributions revealed that only RECT was capable of describing the surface profiles of pitting corrosions. The results of uniform eddy current testing could not distinguish between pitting corrosions and cracks. The probability of detection curves drawn to quantitatively indicate the detection capabilities of the two techniques revealed that uniform eddy current testing with induced eddy currents parallel and perpendicular to weld beads was better than RECT in detecting pitting corrosions on and next to weld beads, respectively. Scanning twice by uniform eddy current testing at orthogonal orientations may be a better process for detecting pitting corrosion on weld overlay cladding compared with using RECT. The measured signals of the two techniques in normal direction were located around the edges of the pitting corrosions, which only indicated the depth around edges. The results suggested that uniform eddy current testing and RECT with normal direction magnetic field signals may be inadequate for evaluating the maximum depth of pitting corrosions or large corrosions.