D. C. Mayes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
D. C. Mayes has a total of 107 co-authors. Here are the top co-authors by number of shared publications:
- Guillaume Pascal Loisel
Sandia National Laboratories
6 shared publications - Christopher John Fontes
Los Alamos National Laboratory
5 shared publications - Robert F. Heeter
Lawrence Livermore National Laboratory 1 , Livermore, California 94550
5 shared publications - Taisuke Nagayama
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
5 shared publications - Theodore Sonne Perry
Los Alamos National Laboratory 5 , Los Alamos, New Mexico 87545
5 shared publications - Yekaterina P. Opachich
Lawrence Livermore National Laboratory 1 , Livermore, California 94550
5 shared publications
Latest Publications
- 1 November 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (11)
AlMg transmission measurements on the National Ignition Facility with novel uncertainty quantification method for point-projection geometry
The opacity platform on the National Ignition Facility (NIF) was developed to study the opacities of important elements in the solar mixture such as Fe and O as well as mid- to high-Z elements. The platform is intended to help address the discrepancy between measured vs calculated opacities first demonstrated in experiments at the Sandia National Laboratories Z-machine. This discrepancy lies at the heart of the solar problem: the fact that helioseismic measurements disagree with stellar structure models, which depend sensitively on calculated opacities. If correct, the opacity measured on Z would substantially reduce the disagreement. An independent platform has been developed at the National Ignition Facility to verify this result and extend opacity measurements to other elements and plasma conditions. The NIF platform employs different methods from Z. Point-projection absorption spectroscopy provides information about the unattenuated, attenuated, and self-emission signals needed to infer transmission, but the measurement is complicated by non-ideal effects. The work described here is based on the Monte Carlo-based uncertainty analysis pioneered by the Z experimental team. Here, we provide similar methods that introduce the capability of accounting for these effects in point-projection geometry for the first time in a statistically rigorous way. The uncertainty analysis method presented here requires dedicated calibration datasets. Enough dedicated calibration datasets have been obtained to enable development of the framework. Additional data will need to be obtained to refine the uncertainty analysis. We apply the method to transmission spectra from Al:Mg plasmas in the ∼1100–1800 eV photon energy range collected using an elliptical crystal spectrometer in a spatially resolving, point-projection geometry.
- 1 November 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (11)
AlMg transmission measurements on the National Ignition Facility with novel uncertainty quantification method for point-projection geometry
The opacity platform on the National Ignition Facility (NIF) was developed to study the opacities of important elements in the solar mixture such as Fe and O as well as mid- to high-Z elements. The platform is intended to help address the discrepancy between measured vs calculated opacities first demonstrated in experiments at the Sandia National Laboratories Z-machine. This discrepancy lies at the heart of the solar problem: the fact that helioseismic measurements disagree with stellar structure models, which depend sensitively on calculated opacities. If correct, the opacity measured on Z would substantially reduce the disagreement. An independent platform has been developed at the National Ignition Facility to verify this result and extend opacity measurements to other elements and plasma conditions. The NIF platform employs different methods from Z. Point-projection absorption spectroscopy provides information about the unattenuated, attenuated, and self-emission signals needed to infer transmission, but the measurement is complicated by non-ideal effects. The work described here is based on the Monte Carlo-based uncertainty analysis pioneered by the Z experimental team. Here, we provide similar methods that introduce the capability of accounting for these effects in point-projection geometry for the first time in a statistically rigorous way. The uncertainty analysis method presented here requires dedicated calibration datasets. Enough dedicated calibration datasets have been obtained to enable development of the framework. Additional data will need to be obtained to refine the uncertainty analysis. We apply the method to transmission spectra from Al:Mg plasmas in the ∼1100–1800 eV photon energy range collected using an elliptical crystal spectrometer in a spatially resolving, point-projection geometry.
- 1 August 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (8)
Expanded higher energy channel for the National Ignition Facility’s soft x-ray opacity spectrometer (OpSpec)
The National Ignition Facility’s soft x-ray opacity spectrometer (OpSpec) currently records time-integrated spectra from ∼550 to 2000 eV. To accomplish this, two elliptical acid-phthalate crystals with different shapes are used together. They are called the low energy and standard energy OpSpec channels and they span roughly 550–1000 and 1000–2000 eV, respectively. Replacing the crystal in the low-energy mount with a PET crystal gives a new higher-energy channel. Slight modifications to the shape of the ellipse give the new channel an energy range of 1750–3000 eV. The new geometry, testing results, and data from the NIF opacity campaign are discussed in this article.
- 1 August 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (8)
Expanded higher energy channel for the National Ignition Facility’s soft x-ray opacity spectrometer (OpSpec)
The National Ignition Facility’s soft x-ray opacity spectrometer (OpSpec) currently records time-integrated spectra from ∼550 to 2000 eV. To accomplish this, two elliptical acid-phthalate crystals with different shapes are used together. They are called the low energy and standard energy OpSpec channels and they span roughly 550–1000 and 1000–2000 eV, respectively. Replacing the crystal in the low-energy mount with a PET crystal gives a new higher-energy channel. Slight modifications to the shape of the ellipse give the new channel an energy range of 1750–3000 eV. The new geometry, testing results, and data from the NIF opacity campaign are discussed in this article.
- Open Access
- 3 December 2025
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 995 (1) , 23
Measurement and Modeling of Electron Temperature in Laboratory Photoionized Plasmas Relevant to Astrophysics
The electron temperature of photoionized plasmas characterizes the thermalization of photoelectrons, impacts the charge-state distribution, emissivity, and opacity through atomic recombination processes, and is needed to perform detailed comparisons with theory predictions. We discuss temperature measurements in laboratory photoionized plasmas and a comparison with model calculations done with several theory approximations and codes. These include a radiation-hydrodynamics simulation and two nonequilibrium heating and ionization models that tracked the evolution of the internal energy of the electrons. Furthermore, for the same physics model and X-ray flux time history, calculations were performed assuming steady-state or time-dependent conditions. The time history of steady-state results correlates with that of the X-ray flux, while that of the time-dependent cases does not, and it is qualitatively and quantitatively different from the steady-state case. Steady-state results significantly overestimated temperature measurements, while time-dependent results produced better approximations, which suggests the importance of transient effects in the experiment and also the need for time-resolved measurements.
- 3 December 2025
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 995 (1) , 23
Open AccessMeasurement and Modeling of Electron Temperature in Laboratory Photoionized Plasmas Relevant to Astrophysics
The electron temperature of photoionized plasmas characterizes the thermalization of photoelectrons, impacts the charge-state distribution, emissivity, and opacity through atomic recombination processes, and is needed to perform detailed comparisons with theory predictions. We discuss temperature measurements in laboratory photoionized plasmas and a comparison with model calculations done with several theory approximations and codes. These include a radiation-hydrodynamics simulation and two nonequilibrium heating and ionization models that tracked the evolution of the internal energy of the electrons. Furthermore, for the same physics model and X-ray flux time history, calculations were performed assuming steady-state or time-dependent conditions. The time history of steady-state results correlates with that of the X-ray flux, while that of the time-dependent cases does not, and it is qualitatively and quantitatively different from the steady-state case. Steady-state results significantly overestimated temperature measurements, while time-dependent results produced better approximations, which suggests the importance of transient effects in the experiment and also the need for time-resolved measurements.
- Open Access
- 12 November 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (20) , 205101
Oxygen Opacity Measurements at High-Energy-Density Conditions
We present the first benchmark measurements of oxygen opacity at high-energy-density, crucial for understanding stellar interiors. A 3 – 5 − μm thick SiO 2 sample was heated using a Z facility x-ray source, and opacity was measured in the 5 – 19.5 Å range with multiple spectrometers. The electron temperature and density inferred from Si K -shell spectra were 148 ± 4 eV and 8.6 ± 1.4 × 10 21 cm − 3 , respectively. Six experiments showed opacity reproducibility within ± 15 % and 5%–25% opacity uncertainty. Measured oxygen opacity and seven different opacity models exhibit extraordinary overall agreement. Discrepancies near the H-like photon ionization threshold and in certain spectral lines suggest the need for model refinements.
- 12 November 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (20) , 205101
Open AccessOxygen Opacity Measurements at High-Energy-Density Conditions
We present the first benchmark measurements of oxygen opacity at high-energy-density, crucial for understanding stellar interiors. A 3 – 5 − μm thick SiO 2 sample was heated using a Z facility x-ray source, and opacity was measured in the 5 – 19.5 Å range with multiple spectrometers. The electron temperature and density inferred from Si K -shell spectra were 148 ± 4 eV and 8.6 ± 1.4 × 10 21 cm − 3 , respectively. Six experiments showed opacity reproducibility within ± 15 % and 5%–25% opacity uncertainty. Measured oxygen opacity and seven different opacity models exhibit extraordinary overall agreement. Discrepancies near the H-like photon ionization threshold and in certain spectral lines suggest the need for model refinements.
- 1 March 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (3)
Sequential spectral line analysis for accurate density and temperature diagnosis of laboratory opacity measurements
The accuracy of iron opacity calculated in stellar interiors has been questioned since the discovery of the “solar problem” and the discrepancies between the measured and modeled iron opacity reported in 2015. Experimental opacity benchmarks require accurate temperature and density measurements, which were inferred by analyzing tracer magnesium spectra in those experiments. Could the observed discrepancy be explained by insufficient accuracy in the inferred temperature, density, and their uncertainties? Previous analyses may have yielded biased results due to three limitations: (1) simultaneous multi-line fitting, (2) approximations in line-shape models, and (3) exclusion of certain spectral lines due to insufficient background characterization. Notably, the first issue is a common concern for many inversion methods, including Bayesian inferences. We present a refined analysis method that overcomes these limitations, applied to three categories of iron opacity experiments (Anchor 1, 2, and 3). In particular, the sequential fitting method yields unbiased results with more realistic uncertainties by accounting for line inconsistencies in the parameter uncertainties. The average electron temperature and density values are 162 ± 6 eV and (7.0 ± 1.9) × 1021 cm−3 for six Anchor 1 experiments, 189 ± 7 eV and (3.4 ± 0.3) × 1022 cm−3 for 21 Anchor 2 experiments, and 201 ± 6 eV and (4.8 ± 1.1) × 1022 cm−3 for nine Anchor 3 experiments. These results show ∼4% temperature and ∼20% density reproducibility over a decade, which also aligns with the inferred parameter uncertainties. The resulting temperature and density uncertainties lead to a quasi-continuum iron opacity variation of ±4%–7% for wavelengths below 9.5 Å, which is insufficient to explain the significant model-data discrepancies reported in 2015.
- 1 March 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (3)
Sequential spectral line analysis for accurate density and temperature diagnosis of laboratory opacity measurements
The accuracy of iron opacity calculated in stellar interiors has been questioned since the discovery of the “solar problem” and the discrepancies between the measured and modeled iron opacity reported in 2015. Experimental opacity benchmarks require accurate temperature and density measurements, which were inferred by analyzing tracer magnesium spectra in those experiments. Could the observed discrepancy be explained by insufficient accuracy in the inferred temperature, density, and their uncertainties? Previous analyses may have yielded biased results due to three limitations: (1) simultaneous multi-line fitting, (2) approximations in line-shape models, and (3) exclusion of certain spectral lines due to insufficient background characterization. Notably, the first issue is a common concern for many inversion methods, including Bayesian inferences. We present a refined analysis method that overcomes these limitations, applied to three categories of iron opacity experiments (Anchor 1, 2, and 3). In particular, the sequential fitting method yields unbiased results with more realistic uncertainties by accounting for line inconsistencies in the parameter uncertainties. The average electron temperature and density values are 162 ± 6 eV and (7.0 ± 1.9) × 1021 cm−3 for six Anchor 1 experiments, 189 ± 7 eV and (3.4 ± 0.3) × 1022 cm−3 for 21 Anchor 2 experiments, and 201 ± 6 eV and (4.8 ± 1.1) × 1022 cm−3 for nine Anchor 3 experiments. These results show ∼4% temperature and ∼20% density reproducibility over a decade, which also aligns with the inferred parameter uncertainties. The resulting temperature and density uncertainties lead to a quasi-continuum iron opacity variation of ±4%–7% for wavelengths below 9.5 Å, which is insufficient to explain the significant model-data discrepancies reported in 2015.
- Open Access
- 27 February 2025
- Published by Elsevier in High Energy Density Physics
- Vol. 55
Overview of oxygen opacity experiments at the National Ignition Facility and investigation of potential systematic errors
- 27 February 2025
- Published by Elsevier in High Energy Density Physics
- Vol. 55
Open AccessOverview of oxygen opacity experiments at the National Ignition Facility and investigation of potential systematic errors
- Open Access
- 1 December 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (12)
Experimental methods to test photoionized plasma models in emission
The expanding foil photoionized plasma platform was developed on the Z-machine at Sandia National Laboratories to produce terrestrial photoionized plasmas at some of the same conditions as those observed in astrophysical black hole accretion disks. The specific scientific goals of the platform are motivated by long-standing astrophysical puzzles related to accreting black hole systems. Ultimately, the experimental goal is to inform the supersolar Fe abundance problem by testing photoionized plasma models in emission with at-parameter laboratory data. High quality high resolution emission data with absolute intensity calibration from a laboratory photoionized plasma have never been collected prior to the experiments described here, providing broader motivation. A robust test of the model predictions requires the successful production of a laboratory photoionized plasma along with measurements of the supporting model inputs including the radiation drive spectrum used to create the photoionized plasma, the electron density, and the temperature. The measured absolute spectral radiance in emission collected from the independently diagnosed plasma can be compared against model calculations performed using the measured inputs. In this paper, we focus on the experimental platform and the model inputs, specifically detailing the methodology used to measure the plasma conditions. The moderate electron temperature of ∼41 eV ± 15 eV and electron density of ∼1e19 ± 1.6e18 e−/cm3 and the ∼3e12 W/cm2 x-ray irradiance at the sample confirm that photoionization dominates the plasma ionization and spectra.
- 1 December 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (12)
Open AccessExperimental methods to test photoionized plasma models in emission
The expanding foil photoionized plasma platform was developed on the Z-machine at Sandia National Laboratories to produce terrestrial photoionized plasmas at some of the same conditions as those observed in astrophysical black hole accretion disks. The specific scientific goals of the platform are motivated by long-standing astrophysical puzzles related to accreting black hole systems. Ultimately, the experimental goal is to inform the supersolar Fe abundance problem by testing photoionized plasma models in emission with at-parameter laboratory data. High quality high resolution emission data with absolute intensity calibration from a laboratory photoionized plasma have never been collected prior to the experiments described here, providing broader motivation. A robust test of the model predictions requires the successful production of a laboratory photoionized plasma along with measurements of the supporting model inputs including the radiation drive spectrum used to create the photoionized plasma, the electron density, and the temperature. The measured absolute spectral radiance in emission collected from the independently diagnosed plasma can be compared against model calculations performed using the measured inputs. In this paper, we focus on the experimental platform and the model inputs, specifically detailing the methodology used to measure the plasma conditions. The moderate electron temperature of ∼41 eV ± 15 eV and electron density of ∼1e19 ± 1.6e18 e−/cm3 and the ∼3e12 W/cm2 x-ray irradiance at the sample confirm that photoionization dominates the plasma ionization and spectra.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Development of improved higher-order correction for the NIF opacity spectrometer
X-ray opacity measurements on the National Ignition Facility (NIF) are in the process of reproducing earlier measurements from the Sandia Z Facility, in particular for oxygen and iron plasmas. These measurements have the potential to revise our understanding of the “solar problem” and of the hot degenerate Q class white dwarf structure by probing plasma conditions near the base of their convection zones. Accurate opacity measurements using soft x-ray Bragg crystal spectrometers require correction for higher-order diffraction effects. Extending prior work in this area [Dutra et al., Review of Scientific Instruments 93, 113527 (2022)], we have developed a new method to remove higher-order spectral components from NIF opacity spectrometer data. By modeling absorption and backlighting continuum spectra and subtracting the second- and third-order components from the measured data, we are able to perform this correction while avoiding imprinting first-order model line features onto the data.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Development of improved higher-order correction for the NIF opacity spectrometer
X-ray opacity measurements on the National Ignition Facility (NIF) are in the process of reproducing earlier measurements from the Sandia Z Facility, in particular for oxygen and iron plasmas. These measurements have the potential to revise our understanding of the “solar problem” and of the hot degenerate Q class white dwarf structure by probing plasma conditions near the base of their convection zones. Accurate opacity measurements using soft x-ray Bragg crystal spectrometers require correction for higher-order diffraction effects. Extending prior work in this area [Dutra et al., Review of Scientific Instruments 93, 113527 (2022)], we have developed a new method to remove higher-order spectral components from NIF opacity spectrometer data. By modeling absorption and backlighting continuum spectra and subtracting the second- and third-order components from the measured data, we are able to perform this correction while avoiding imprinting first-order model line features onto the data.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Design and characterization of the time-resolved opacity spectrometer (OpSpecTR) for the NIF iron opacity campaign
A new time-resolved opacity spectrometer (OpSpecTR) is currently under development for the National Ignition Facility (NIF) opacity campaign. The spectrometer utilizes Icarus version 2 (IV2) hybridized complementary metal–oxide–semiconductor sensors to collect gated data at the time of the opacity transmission signal, unlocking the ability to collect higher-temperature measurements on NIF. Experimental conditions to achieve higher temperatures are feasible; however, backgrounds will dominate the data collected by the current time-integrating opacity spectrometer. The shortest available OpSpecTR integration time of ∼2 ns is predicted to reduce self-emission and other late-time backgrounds by up to 80%. Initially, three Icarus sensors will be used to collect data in the self-emission, backlighter, and absorption regions of the transmission spectrum, with plans to upgrade to five Daedalus sensors in future implementations with integration times of ∼1.3 ns. We present the details of the diagnostic design along with recent characterization results of the IV2 sensors.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Design and characterization of the time-resolved opacity spectrometer (OpSpecTR) for the NIF iron opacity campaign
A new time-resolved opacity spectrometer (OpSpecTR) is currently under development for the National Ignition Facility (NIF) opacity campaign. The spectrometer utilizes Icarus version 2 (IV2) hybridized complementary metal–oxide–semiconductor sensors to collect gated data at the time of the opacity transmission signal, unlocking the ability to collect higher-temperature measurements on NIF. Experimental conditions to achieve higher temperatures are feasible; however, backgrounds will dominate the data collected by the current time-integrating opacity spectrometer. The shortest available OpSpecTR integration time of ∼2 ns is predicted to reduce self-emission and other late-time backgrounds by up to 80%. Initially, three Icarus sensors will be used to collect data in the self-emission, backlighter, and absorption regions of the transmission spectrum, with plans to upgrade to five Daedalus sensors in future implementations with integration times of ∼1.3 ns. We present the details of the diagnostic design along with recent characterization results of the IV2 sensors.
- Open Access
- 1 May 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (5)
A generalized approach to x-ray data modeling for high-energy-density plasma experiments
Accurate understanding of x-ray diagnostics is crucial for both interpreting high-energy-density experiments and testing simulations through quantitative comparisons. X-ray diagnostic models are complex. Past treatments of individual x-ray diagnostics on a case-by-case basis have hindered universal diagnostic understanding. Here, we derive a general formula for modeling the absolute response of non-focusing x-ray diagnostics, such as x-ray imagers, one-dimensional space-resolved spectrometers, and x-ray power diagnostics. The present model is useful for both data modeling and data processing. It naturally accounts for the x-ray crystal broadening. The new model verifies that standard approaches for a crystal response can be good approximations, but they can underestimate the total reflectivity and overestimate spectral resolving power by more than a factor of 2 in some cases near reflectivity edge features. We also find that a frequently used, simplified-crystal-response approximation for processing spectral data can introduce an absolute error of more than an order of magnitude and the relative spectral radiance error of a factor of 3. The present model is derived with straightforward geometric arguments. It is more general and is recommended for developing a unified picture and providing consistent treatment over multiple x-ray diagnostics. Such consistency is crucial for reliable multi-objective data analyses.
- 1 May 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (5)
Open AccessA generalized approach to x-ray data modeling for high-energy-density plasma experiments
Accurate understanding of x-ray diagnostics is crucial for both interpreting high-energy-density experiments and testing simulations through quantitative comparisons. X-ray diagnostic models are complex. Past treatments of individual x-ray diagnostics on a case-by-case basis have hindered universal diagnostic understanding. Here, we derive a general formula for modeling the absolute response of non-focusing x-ray diagnostics, such as x-ray imagers, one-dimensional space-resolved spectrometers, and x-ray power diagnostics. The present model is useful for both data modeling and data processing. It naturally accounts for the x-ray crystal broadening. The new model verifies that standard approaches for a crystal response can be good approximations, but they can underestimate the total reflectivity and overestimate spectral resolving power by more than a factor of 2 in some cases near reflectivity edge features. We also find that a frequently used, simplified-crystal-response approximation for processing spectral data can introduce an absolute error of more than an order of magnitude and the relative spectral radiance error of a factor of 3. The present model is derived with straightforward geometric arguments. It is more general and is recommended for developing a unified picture and providing consistent treatment over multiple x-ray diagnostics. Such consistency is crucial for reliable multi-objective data analyses.