Liping Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Liping Chen has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Xinjian Feng
State Key Laboratory of Bioinspired Interfacial Materials Science, College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215123, China
10 shared publications Yifan Zhou
State Key Laboratory of Bioinspired Interfacial Materials Science, College of Chemistry Chemical Engineering and Materials Science Soochow University Suzhou China
6 shared publicationsDandan Wang
College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215123, China
5 shared publications- Zhenyao Ding
College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215123, China
5 shared publications - Weihai Ni
Jiangsu Key Laboratory of Frontier Material Physics and Devices, School of Physical Science and Technology, Soochow University, Suzhou, Jiangsu 215006, China
3 shared publications - Dandan Wang
College of Chemistry Chemical Engineering and Materials Science Soochow University Suzhou 215123 China
2 shared publications
Latest Publications
- 1 September 2026
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 62 (68) , 17022-17026
An interference-resistant electrocatalyst for selective H 2 O 2 oxidation enabled by an atomic layer deposited oxide coating
The oxide coatings modified on the platinum-based catalyst can selectively permeate H 2 O 2 and exhibit anti-interference performance.
- 1 September 2026
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 62 (68) , 17022-17026
An interference-resistant electrocatalyst for selective H 2 O 2 oxidation enabled by an atomic layer deposited oxide coating
The oxide coatings modified on the platinum-based catalyst can selectively permeate H 2 O 2 and exhibit anti-interference performance.
Enhancing Oxidase‐Catalyzed Biosensing via Hydrophobic ZIF‐7 Nanomaterials: A Micro‐Triphase Interface Approach
Electrochemical bioassays based on oxidase reactions are widely used in biological sciences and medical industries. However, the enzymatic reaction kinetics are significantly restricted by the poor solubility and slow diffusion rate of oxygen in conventional solid‐liquid diphase reaction system. This limitation compromises the detection accuracy, linearity and reliability of oxidase‐based bioassays. In this study, an effective solid‒liquid‒air triphase bioassay system is provided that uses ZIF‐7 nanoparticles (ZIF‐7 NPs) as oxygen nanocarriers. We constructed a solid−liquid−air triphase enzyme electrode by encapsulating ZIF‐7 NPs within an oxidase network. The hydrophobic nature of ZIF‐7 NPs provides localized oxygen supply by releasing pre‐stored oxygen from its hydrophobic pores, thereby enhancing the kinetics of oxidase‐catalyzed reactions. Consequently, compared to the conventional diphase system, the triphase system significantly improves the enzymatic reaction kinetics with a 21‐fold higher maximum reaction rate ( V max ) and expands the linear detection range for glucose from 2 mM to 20 mM, a 10‐fold improvement. Furthermore, this triphase technique can be applied to the detection of other biomolecules, and the design strategy offers a new route to addressing the gas deficiency problem in catalytic reactions that involve gas consumption.
Enhancing Oxidase‐Catalyzed Biosensing via Hydrophobic ZIF‐7 Nanomaterials: A Micro‐Triphase Interface Approach
Electrochemical bioassays based on oxidase reactions are widely used in biological sciences and medical industries. However, the enzymatic reaction kinetics are significantly restricted by the poor solubility and slow diffusion rate of oxygen in conventional solid‐liquid diphase reaction system. This limitation compromises the detection accuracy, linearity and reliability of oxidase‐based bioassays. In this study, an effective solid‒liquid‒air triphase bioassay system is provided that uses ZIF‐7 nanoparticles (ZIF‐7 NPs) as oxygen nanocarriers. We constructed a solid−liquid−air triphase enzyme electrode by encapsulating ZIF‐7 NPs within an oxidase network. The hydrophobic nature of ZIF‐7 NPs provides localized oxygen supply by releasing pre‐stored oxygen from its hydrophobic pores, thereby enhancing the kinetics of oxidase‐catalyzed reactions. Consequently, compared to the conventional diphase system, the triphase system significantly improves the enzymatic reaction kinetics with a 21‐fold higher maximum reaction rate ( V max ) and expands the linear detection range for glucose from 2 mM to 20 mM, a 10‐fold improvement. Furthermore, this triphase technique can be applied to the detection of other biomolecules, and the design strategy offers a new route to addressing the gas deficiency problem in catalytic reactions that involve gas consumption.
- 9 June 2025
- Published by Royal Society of Chemistry (RSC) in Materials Horizons
- Vol. 12 (17) , 6938-6944
High O 2 tolerant metal-based catalysts for selective H 2 O 2 reduction by constructing an ultra-thin oxide passivation layer
An ultra-thin SnO 2 layer is modified on noble metal-based catalysts as a passivation layer to enhance H 2 O 2 selectivity.
- 9 June 2025
- Published by Royal Society of Chemistry (RSC) in Materials Horizons
- Vol. 12 (17) , 6938-6944
High O 2 tolerant metal-based catalysts for selective H 2 O 2 reduction by constructing an ultra-thin oxide passivation layer
An ultra-thin SnO 2 layer is modified on noble metal-based catalysts as a passivation layer to enhance H 2 O 2 selectivity.
- 28 May 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (23) , 34733-34740
Engineering Hollow Nanospheres with Hydrophobic@Hydrophilic Amphiphilic Properties for Enhanced Enzymatic Reactions and High-Performance Bioassays
Gaseous reactant-involved heterogeneous catalysis, particularly oxygen-dependent biocatalysis, generally faces inherent challenges related to the low solubility and low diffusion coefficients of oxygen in aqueous solutions. In this study, we report an efficient air-liquid-solid triphase oxidase enzymatic reaction and bioassay system that utilizes hollow hydrophobic@hydrophilic amphiphilic nanospheres as oxygen nanocarriers. The unique hollow porous structure and hydrophobic internal surface facilitate the storage of oxygen for oxidase enzymatic reactions as revealed by single nanoparticle dark-field microscopy. The outer hydrophilic layer facilitates uniform coating of the oxidase and ensures effective contact with the aqueous solution. This configuration creates an interfacial microenvironment that promotes rapid gas and liquid mass transfer, subsequently increasing the reaction rate of glucose oxidase (a model enzyme) catalysis by a factor of 6.6. Consequently, the triphase bioassay demonstrates superior performance in glucose detection, exhibiting a linear range of up to 30 mM, which is 15 times greater than that of the diphase system. Moreover, the triphase system has great potential for the determination of various biomarkers. This study provides a novel solution to the gaseous reactant deficiency issue encountered in heterogeneous catalysis.
- 28 May 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (23) , 34733-34740
Engineering Hollow Nanospheres with Hydrophobic@Hydrophilic Amphiphilic Properties for Enhanced Enzymatic Reactions and High-Performance Bioassays
Gaseous reactant-involved heterogeneous catalysis, particularly oxygen-dependent biocatalysis, generally faces inherent challenges related to the low solubility and low diffusion coefficients of oxygen in aqueous solutions. In this study, we report an efficient air-liquid-solid triphase oxidase enzymatic reaction and bioassay system that utilizes hollow hydrophobic@hydrophilic amphiphilic nanospheres as oxygen nanocarriers. The unique hollow porous structure and hydrophobic internal surface facilitate the storage of oxygen for oxidase enzymatic reactions as revealed by single nanoparticle dark-field microscopy. The outer hydrophilic layer facilitates uniform coating of the oxidase and ensures effective contact with the aqueous solution. This configuration creates an interfacial microenvironment that promotes rapid gas and liquid mass transfer, subsequently increasing the reaction rate of glucose oxidase (a model enzyme) catalysis by a factor of 6.6. Consequently, the triphase bioassay demonstrates superior performance in glucose detection, exhibiting a linear range of up to 30 mM, which is 15 times greater than that of the diphase system. Moreover, the triphase system has great potential for the determination of various biomarkers. This study provides a novel solution to the gaseous reactant deficiency issue encountered in heterogeneous catalysis.
- 17 August 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (34) , 44341-44349
Triphase Enzyme Electrode Based on ZIF-8 with Enhanced Oxidase Catalytic Kinetics and Bioassay Performance
Oxidase enzyme-based electrochemical bioassays have garnered considerable interest due to their specificity and high efficiency. However, in traditional solid-liquid diphase enzyme electrode systems, the low solubility of oxygen and its slow mass transfer rate limit the oxidase catalytic reaction kinetics, thereby affecting the bioassay performance, including the detection accuracy, sensitivity, and linear dynamic range. ZIF-8 nanoparticles (NPs) possess hydrophobic and high-porosity characteristics, enabling them to serve as oxygen nanocarriers. In this work, we constructed a solid-liquid-air triphase enzyme electrode by encapsulating ZIF-8 NPs within an oxidase network. Hydrophobic ZIF-8 NPs can provide a rapid and sufficient supply of oxygen for the oxidase-catalyzed reactions, which enhances and stabilizes the kinetics of oxidase-catalyzed reactions. This approach eliminates the issue of "oxygen deficiency" at the traditional solid-liquid diphase interface. Consequently, the triphase enzyme electrode exhibits a 12-fold higher linear detection range than the diphase system and possesses good detection accuracy in electrolytes even with fluctuating oxygen levels. This work proposes a novel approach to construct triphase reaction systems for addressing the gas deficiency problem in heterogeneous catalysis.
- 17 August 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (34) , 44341-44349
Triphase Enzyme Electrode Based on ZIF-8 with Enhanced Oxidase Catalytic Kinetics and Bioassay Performance
Oxidase enzyme-based electrochemical bioassays have garnered considerable interest due to their specificity and high efficiency. However, in traditional solid-liquid diphase enzyme electrode systems, the low solubility of oxygen and its slow mass transfer rate limit the oxidase catalytic reaction kinetics, thereby affecting the bioassay performance, including the detection accuracy, sensitivity, and linear dynamic range. ZIF-8 nanoparticles (NPs) possess hydrophobic and high-porosity characteristics, enabling them to serve as oxygen nanocarriers. In this work, we constructed a solid-liquid-air triphase enzyme electrode by encapsulating ZIF-8 NPs within an oxidase network. Hydrophobic ZIF-8 NPs can provide a rapid and sufficient supply of oxygen for the oxidase-catalyzed reactions, which enhances and stabilizes the kinetics of oxidase-catalyzed reactions. This approach eliminates the issue of "oxygen deficiency" at the traditional solid-liquid diphase interface. Consequently, the triphase enzyme electrode exhibits a 12-fold higher linear detection range than the diphase system and possesses good detection accuracy in electrolytes even with fluctuating oxygen levels. This work proposes a novel approach to construct triphase reaction systems for addressing the gas deficiency problem in heterogeneous catalysis.
- 6 June 2024
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 146 (24) , 16581-16589
Surface Defect and Wettability Engineering of Porous SnOx for Reliable Bioassays with High Selectivity and Wide Linear Dynamic Range
Bioassay systems that can selectively detect biomarkers at both high and low levels are of great importance for clinical diagnosis. In this work, we report an enzyme electrode with an oxygen reduction reaction (ORR)-tolerant H2O2 reduction property and an air-liquid-solid triphase interface microenvironment by regulating the surface defects and wettability of nanoporous tin oxide (SnOx). The enzyme electrode allows the oxygen that is required for the oxidase catalytic reaction to be transported from the air phase to the reaction zone, which greatly enhances the enzymatic kinetics and increases the linear detection upper limit. Meanwhile, the ORR-tolerant H2O2 reduction property of SnOx catalysts achieved via oxygen vacancy engineering greatly reduces the interferent signals caused by oxygen and various easily oxidizable endogenous/exogenous species, which enables the selective detection of biomarkers at trace levels. The synergistic effect between these two novel qualities features a bioassay system with a wide dynamic linear range and high selectivity for the accurate detection of a wide range of biomarkers, such as glucose, lactic acid, uric acid, and galactose, offering the potential for reliable clinical diagnosis applications.
- 6 June 2024
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 146 (24) , 16581-16589
Surface Defect and Wettability Engineering of Porous SnOx for Reliable Bioassays with High Selectivity and Wide Linear Dynamic Range
Bioassay systems that can selectively detect biomarkers at both high and low levels are of great importance for clinical diagnosis. In this work, we report an enzyme electrode with an oxygen reduction reaction (ORR)-tolerant H2O2 reduction property and an air-liquid-solid triphase interface microenvironment by regulating the surface defects and wettability of nanoporous tin oxide (SnOx). The enzyme electrode allows the oxygen that is required for the oxidase catalytic reaction to be transported from the air phase to the reaction zone, which greatly enhances the enzymatic kinetics and increases the linear detection upper limit. Meanwhile, the ORR-tolerant H2O2 reduction property of SnOx catalysts achieved via oxygen vacancy engineering greatly reduces the interferent signals caused by oxygen and various easily oxidizable endogenous/exogenous species, which enables the selective detection of biomarkers at trace levels. The synergistic effect between these two novel qualities features a bioassay system with a wide dynamic linear range and high selectivity for the accurate detection of a wide range of biomarkers, such as glucose, lactic acid, uric acid, and galactose, offering the potential for reliable clinical diagnosis applications.
- 30 January 2024
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 40 (6) , 3241-3247
Oxygen Vacancy Engineering of FeOx toward Oxygen-Tolerant Hydrogen Peroxide Reduction for Reliable Bioassays
The accurate determination of hydrogen peroxide (H2O2), an important clinical disease relevant biomarker, is of great importance for the diagnosis and management of illnesses. By using the cathodic monitoring approach, H2O2 can be accurately detected because interfering signals from easily oxidizable endogenous and exogenous species in biofluids can be avoided. However, the simultaneous occurrence of the oxygen reduction reaction (ORR) restricts the practical use of this cathodic method. In this study, via oxygen vacancy modulation, we synthesized FeOx catalysts that can selectively reduce H2O2 over O-2. The H2O2 detection system based on this catalyst exhibits an outstanding ORR inhibition ability. Furthermore, by integrating this catalyst with glucose oxidase, a model enzyme, a reliable bioassay system was developed that can selectively detect glucose over a wide variety of interferents in artificially simulated tissue fluids. The bioassay system employing this catalyst in conjunction with oxidases is generally applicable to accurate detect a wide range of biomarkers.
- 30 January 2024
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 40 (6) , 3241-3247
Oxygen Vacancy Engineering of FeOx toward Oxygen-Tolerant Hydrogen Peroxide Reduction for Reliable Bioassays
The accurate determination of hydrogen peroxide (H2O2), an important clinical disease relevant biomarker, is of great importance for the diagnosis and management of illnesses. By using the cathodic monitoring approach, H2O2 can be accurately detected because interfering signals from easily oxidizable endogenous and exogenous species in biofluids can be avoided. However, the simultaneous occurrence of the oxygen reduction reaction (ORR) restricts the practical use of this cathodic method. In this study, via oxygen vacancy modulation, we synthesized FeOx catalysts that can selectively reduce H2O2 over O-2. The H2O2 detection system based on this catalyst exhibits an outstanding ORR inhibition ability. Furthermore, by integrating this catalyst with glucose oxidase, a model enzyme, a reliable bioassay system was developed that can selectively detect glucose over a wide variety of interferents in artificially simulated tissue fluids. The bioassay system employing this catalyst in conjunction with oxidases is generally applicable to accurate detect a wide range of biomarkers.
Engineering a Hollow Carbon Sphere‐Based Triphase Microenvironment for Enhanced Enzymatic Reaction Kinetics and Bioassay Performance
Electrochemical bioassays based on oxidase reactions are frequently used in biological sciences and medical industries. However, the enzymatic reaction kinetics are severely restricted by the poor solubility and slow diffusion rate of oxygen in conventional solid‒liquid diphase reaction systems, which inevitably compromises the detection accuracy, linearity, and reliability of the oxidase‐based bioassay. Herein, an effective solid‒liquid‒air triphase bioassay system is provided that uses hydrophobic hollow carbon spheres (HCSs) as oxygen nanocarriers. The oxygen stored in the cavity of HCS can rapidly diffuse to the oxidase active sites through the mesoporous carbon shell, providing sufficient oxygen for oxidase‐based enzymatic reactions. As a result, the triphase system can significantly improve the enzymatic reaction kinetics and obtain a 20‐fold higher linear detection range than the normal diphase system. Other biomolecules can also be determined using this triphase technique, and the triphase design strategy offers a new route to address the gas deficiency problem in catalytic reactions that involve gas consumption.
Engineering a Hollow Carbon Sphere‐Based Triphase Microenvironment for Enhanced Enzymatic Reaction Kinetics and Bioassay Performance
Electrochemical bioassays based on oxidase reactions are frequently used in biological sciences and medical industries. However, the enzymatic reaction kinetics are severely restricted by the poor solubility and slow diffusion rate of oxygen in conventional solid‒liquid diphase reaction systems, which inevitably compromises the detection accuracy, linearity, and reliability of the oxidase‐based bioassay. Herein, an effective solid‒liquid‒air triphase bioassay system is provided that uses hydrophobic hollow carbon spheres (HCSs) as oxygen nanocarriers. The oxygen stored in the cavity of HCS can rapidly diffuse to the oxidase active sites through the mesoporous carbon shell, providing sufficient oxygen for oxidase‐based enzymatic reactions. As a result, the triphase system can significantly improve the enzymatic reaction kinetics and obtain a 20‐fold higher linear detection range than the normal diphase system. Other biomolecules can also be determined using this triphase technique, and the triphase design strategy offers a new route to address the gas deficiency problem in catalytic reactions that involve gas consumption.
- Open Access
Superhydrophobicity‐mediated enhanced enzymatic kinetics and high‐performance bioassays
As a typical superwettability behavior, superhydrophobicity can provide an appropriate strategy to enhance the mass transport in multiphase chemical reactions. In the oxidase‐based enzymatic reactions, the elaborately regulating of reactant oxygen are critical to the development of an oxidase‐based high‐performance biosensor. In solid–liquid diphase condition, however, the kinetics of oxidase‐catalyzed reactions is inhibited by delayed mass transport and poor solubility of oxygen. To address this limitation, the design of the solid–liquid–air triphase interface is proposed according to the binary cooperation of superhydrophobicity and hydrophilicity. On the triphase joint interface, oxygen required for the oxidase‐catalyzed reactions can diffuse directly to the reaction center from the air phase through the micro/nanostructured superhydrophobic substrate, thus improving the kinetics of the oxidase‐catalyzed reactions. In this minireview, we summarize recent advances in the fabrication of triphase reaction system based on different superhydrophobic substrate for oxidase‐based biosensors. Common substrates including fibrous network, nanowire arrays, 3D porous framework, and hollow sphere structures are outlined in categories.
Open AccessSuperhydrophobicity‐mediated enhanced enzymatic kinetics and high‐performance bioassays
As a typical superwettability behavior, superhydrophobicity can provide an appropriate strategy to enhance the mass transport in multiphase chemical reactions. In the oxidase‐based enzymatic reactions, the elaborately regulating of reactant oxygen are critical to the development of an oxidase‐based high‐performance biosensor. In solid–liquid diphase condition, however, the kinetics of oxidase‐catalyzed reactions is inhibited by delayed mass transport and poor solubility of oxygen. To address this limitation, the design of the solid–liquid–air triphase interface is proposed according to the binary cooperation of superhydrophobicity and hydrophilicity. On the triphase joint interface, oxygen required for the oxidase‐catalyzed reactions can diffuse directly to the reaction center from the air phase through the micro/nanostructured superhydrophobic substrate, thus improving the kinetics of the oxidase‐catalyzed reactions. In this minireview, we summarize recent advances in the fabrication of triphase reaction system based on different superhydrophobic substrate for oxidase‐based biosensors. Common substrates including fibrous network, nanowire arrays, 3D porous framework, and hollow sphere structures are outlined in categories.
- 5 December 2022
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 38 (50) , 15796-15803
High-Performance Photoelectrochemical Enzymatic Bioanalysis Based on a 3D Porous CuxO@TiO2 Film with a Solid–Liquid–Air Triphase Interface
The accurate detection of H2O2 is crucial in oxidase-based cathodic photoelectrochemical enzymatic bioanalysis but will be easily compromised in the conventional photoelectrode-electrolyte diphase system due to the fluctuation of oxygen levels and the similar reduction potential between oxygen and H2O2. Herein, a solid-liquid-air triphase bio-photocathode based on a superhydrophobic three-dimensional (3D) porous micro-nano-hierarchical structured CuxO@TiO2 film that was constructed by controlling the wettability of the electrode surface is reported. The triphase photoelectrochemical system ensures an oxygen-rich interface microenvironment with constant and sufficiently high oxygen concentration. Moreover, the 3D porous micro-nano-hierarchical structures possess abundant active catalytic sites and a multidimensional electron transport pathway. The synergistic effect of the improved oxygen supply and the photoelectrode architecture greatly stabilizes and enhances the kinetics of the enzymatic reaction and H2O2 cathodic reaction, resulting in a 60-fold broader linear detection range and a higher accuracy compared with the conventional solid-liquid diphase system.
- 5 December 2022
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 38 (50) , 15796-15803
High-Performance Photoelectrochemical Enzymatic Bioanalysis Based on a 3D Porous CuxO@TiO2 Film with a Solid–Liquid–Air Triphase Interface
The accurate detection of H2O2 is crucial in oxidase-based cathodic photoelectrochemical enzymatic bioanalysis but will be easily compromised in the conventional photoelectrode-electrolyte diphase system due to the fluctuation of oxygen levels and the similar reduction potential between oxygen and H2O2. Herein, a solid-liquid-air triphase bio-photocathode based on a superhydrophobic three-dimensional (3D) porous micro-nano-hierarchical structured CuxO@TiO2 film that was constructed by controlling the wettability of the electrode surface is reported. The triphase photoelectrochemical system ensures an oxygen-rich interface microenvironment with constant and sufficiently high oxygen concentration. Moreover, the 3D porous micro-nano-hierarchical structures possess abundant active catalytic sites and a multidimensional electron transport pathway. The synergistic effect of the improved oxygen supply and the photoelectrode architecture greatly stabilizes and enhances the kinetics of the enzymatic reaction and H2O2 cathodic reaction, resulting in a 60-fold broader linear detection range and a higher accuracy compared with the conventional solid-liquid diphase system.