Zhenyao Ding
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhenyao Ding has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Xinjian Feng
State Key Laboratory of Bioinspired Interfacial Materials Science, College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215123, China
6 shared publications - Liping Chen
State Key Laboratory of Bioinspired Interfacial Materials Science, College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215123, China
5 shared publications Dandan Wang
College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215123, China
4 shared publicationsYifan Zhou
State Key Laboratory of Bioinspired Interfacial Materials Science, College of Chemistry, Chemical Engineering and Materials Science
4 shared publicationsHang Zhou
College of Chemistry, Chemical Engineering and Materials Science Soochow University Suzhou 215123 P. R. China
2 shared publications- Weihai Ni
Jiangsu Key Laboratory of Frontier Material Physics and Devices, School of Physical Science and Technology, Soochow University, Suzhou, Jiangsu 215006, China
2 shared publications
Latest Publications
- 28 May 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (23) , 34733-34740
Engineering Hollow Nanospheres with Hydrophobic@Hydrophilic Amphiphilic Properties for Enhanced Enzymatic Reactions and High-Performance Bioassays
Gaseous reactant-involved heterogeneous catalysis, particularly oxygen-dependent biocatalysis, generally faces inherent challenges related to the low solubility and low diffusion coefficients of oxygen in aqueous solutions. In this study, we report an efficient air-liquid-solid triphase oxidase enzymatic reaction and bioassay system that utilizes hollow hydrophobic@hydrophilic amphiphilic nanospheres as oxygen nanocarriers. The unique hollow porous structure and hydrophobic internal surface facilitate the storage of oxygen for oxidase enzymatic reactions as revealed by single nanoparticle dark-field microscopy. The outer hydrophilic layer facilitates uniform coating of the oxidase and ensures effective contact with the aqueous solution. This configuration creates an interfacial microenvironment that promotes rapid gas and liquid mass transfer, subsequently increasing the reaction rate of glucose oxidase (a model enzyme) catalysis by a factor of 6.6. Consequently, the triphase bioassay demonstrates superior performance in glucose detection, exhibiting a linear range of up to 30 mM, which is 15 times greater than that of the diphase system. Moreover, the triphase system has great potential for the determination of various biomarkers. This study provides a novel solution to the gaseous reactant deficiency issue encountered in heterogeneous catalysis.
- 28 May 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (23) , 34733-34740
Engineering Hollow Nanospheres with Hydrophobic@Hydrophilic Amphiphilic Properties for Enhanced Enzymatic Reactions and High-Performance Bioassays
Gaseous reactant-involved heterogeneous catalysis, particularly oxygen-dependent biocatalysis, generally faces inherent challenges related to the low solubility and low diffusion coefficients of oxygen in aqueous solutions. In this study, we report an efficient air-liquid-solid triphase oxidase enzymatic reaction and bioassay system that utilizes hollow hydrophobic@hydrophilic amphiphilic nanospheres as oxygen nanocarriers. The unique hollow porous structure and hydrophobic internal surface facilitate the storage of oxygen for oxidase enzymatic reactions as revealed by single nanoparticle dark-field microscopy. The outer hydrophilic layer facilitates uniform coating of the oxidase and ensures effective contact with the aqueous solution. This configuration creates an interfacial microenvironment that promotes rapid gas and liquid mass transfer, subsequently increasing the reaction rate of glucose oxidase (a model enzyme) catalysis by a factor of 6.6. Consequently, the triphase bioassay demonstrates superior performance in glucose detection, exhibiting a linear range of up to 30 mM, which is 15 times greater than that of the diphase system. Moreover, the triphase system has great potential for the determination of various biomarkers. This study provides a novel solution to the gaseous reactant deficiency issue encountered in heterogeneous catalysis.
- 6 June 2024
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 146 (24) , 16581-16589
Surface Defect and Wettability Engineering of Porous SnOx for Reliable Bioassays with High Selectivity and Wide Linear Dynamic Range
Bioassay systems that can selectively detect biomarkers at both high and low levels are of great importance for clinical diagnosis. In this work, we report an enzyme electrode with an oxygen reduction reaction (ORR)-tolerant H2O2 reduction property and an air-liquid-solid triphase interface microenvironment by regulating the surface defects and wettability of nanoporous tin oxide (SnOx). The enzyme electrode allows the oxygen that is required for the oxidase catalytic reaction to be transported from the air phase to the reaction zone, which greatly enhances the enzymatic kinetics and increases the linear detection upper limit. Meanwhile, the ORR-tolerant H2O2 reduction property of SnOx catalysts achieved via oxygen vacancy engineering greatly reduces the interferent signals caused by oxygen and various easily oxidizable endogenous/exogenous species, which enables the selective detection of biomarkers at trace levels. The synergistic effect between these two novel qualities features a bioassay system with a wide dynamic linear range and high selectivity for the accurate detection of a wide range of biomarkers, such as glucose, lactic acid, uric acid, and galactose, offering the potential for reliable clinical diagnosis applications.
- 6 June 2024
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 146 (24) , 16581-16589
Surface Defect and Wettability Engineering of Porous SnOx for Reliable Bioassays with High Selectivity and Wide Linear Dynamic Range
Bioassay systems that can selectively detect biomarkers at both high and low levels are of great importance for clinical diagnosis. In this work, we report an enzyme electrode with an oxygen reduction reaction (ORR)-tolerant H2O2 reduction property and an air-liquid-solid triphase interface microenvironment by regulating the surface defects and wettability of nanoporous tin oxide (SnOx). The enzyme electrode allows the oxygen that is required for the oxidase catalytic reaction to be transported from the air phase to the reaction zone, which greatly enhances the enzymatic kinetics and increases the linear detection upper limit. Meanwhile, the ORR-tolerant H2O2 reduction property of SnOx catalysts achieved via oxygen vacancy engineering greatly reduces the interferent signals caused by oxygen and various easily oxidizable endogenous/exogenous species, which enables the selective detection of biomarkers at trace levels. The synergistic effect between these two novel qualities features a bioassay system with a wide dynamic linear range and high selectivity for the accurate detection of a wide range of biomarkers, such as glucose, lactic acid, uric acid, and galactose, offering the potential for reliable clinical diagnosis applications.
- 30 January 2024
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 40 (6) , 3241-3247
Oxygen Vacancy Engineering of FeOx toward Oxygen-Tolerant Hydrogen Peroxide Reduction for Reliable Bioassays
The accurate determination of hydrogen peroxide (H2O2), an important clinical disease relevant biomarker, is of great importance for the diagnosis and management of illnesses. By using the cathodic monitoring approach, H2O2 can be accurately detected because interfering signals from easily oxidizable endogenous and exogenous species in biofluids can be avoided. However, the simultaneous occurrence of the oxygen reduction reaction (ORR) restricts the practical use of this cathodic method. In this study, via oxygen vacancy modulation, we synthesized FeOx catalysts that can selectively reduce H2O2 over O-2. The H2O2 detection system based on this catalyst exhibits an outstanding ORR inhibition ability. Furthermore, by integrating this catalyst with glucose oxidase, a model enzyme, a reliable bioassay system was developed that can selectively detect glucose over a wide variety of interferents in artificially simulated tissue fluids. The bioassay system employing this catalyst in conjunction with oxidases is generally applicable to accurate detect a wide range of biomarkers.
- 30 January 2024
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 40 (6) , 3241-3247
Oxygen Vacancy Engineering of FeOx toward Oxygen-Tolerant Hydrogen Peroxide Reduction for Reliable Bioassays
The accurate determination of hydrogen peroxide (H2O2), an important clinical disease relevant biomarker, is of great importance for the diagnosis and management of illnesses. By using the cathodic monitoring approach, H2O2 can be accurately detected because interfering signals from easily oxidizable endogenous and exogenous species in biofluids can be avoided. However, the simultaneous occurrence of the oxygen reduction reaction (ORR) restricts the practical use of this cathodic method. In this study, via oxygen vacancy modulation, we synthesized FeOx catalysts that can selectively reduce H2O2 over O-2. The H2O2 detection system based on this catalyst exhibits an outstanding ORR inhibition ability. Furthermore, by integrating this catalyst with glucose oxidase, a model enzyme, a reliable bioassay system was developed that can selectively detect glucose over a wide variety of interferents in artificially simulated tissue fluids. The bioassay system employing this catalyst in conjunction with oxidases is generally applicable to accurate detect a wide range of biomarkers.
Engineering a Hollow Carbon Sphere‐Based Triphase Microenvironment for Enhanced Enzymatic Reaction Kinetics and Bioassay Performance
Electrochemical bioassays based on oxidase reactions are frequently used in biological sciences and medical industries. However, the enzymatic reaction kinetics are severely restricted by the poor solubility and slow diffusion rate of oxygen in conventional solid‒liquid diphase reaction systems, which inevitably compromises the detection accuracy, linearity, and reliability of the oxidase‐based bioassay. Herein, an effective solid‒liquid‒air triphase bioassay system is provided that uses hydrophobic hollow carbon spheres (HCSs) as oxygen nanocarriers. The oxygen stored in the cavity of HCS can rapidly diffuse to the oxidase active sites through the mesoporous carbon shell, providing sufficient oxygen for oxidase‐based enzymatic reactions. As a result, the triphase system can significantly improve the enzymatic reaction kinetics and obtain a 20‐fold higher linear detection range than the normal diphase system. Other biomolecules can also be determined using this triphase technique, and the triphase design strategy offers a new route to address the gas deficiency problem in catalytic reactions that involve gas consumption.
Engineering a Hollow Carbon Sphere‐Based Triphase Microenvironment for Enhanced Enzymatic Reaction Kinetics and Bioassay Performance
Electrochemical bioassays based on oxidase reactions are frequently used in biological sciences and medical industries. However, the enzymatic reaction kinetics are severely restricted by the poor solubility and slow diffusion rate of oxygen in conventional solid‒liquid diphase reaction systems, which inevitably compromises the detection accuracy, linearity, and reliability of the oxidase‐based bioassay. Herein, an effective solid‒liquid‒air triphase bioassay system is provided that uses hydrophobic hollow carbon spheres (HCSs) as oxygen nanocarriers. The oxygen stored in the cavity of HCS can rapidly diffuse to the oxidase active sites through the mesoporous carbon shell, providing sufficient oxygen for oxidase‐based enzymatic reactions. As a result, the triphase system can significantly improve the enzymatic reaction kinetics and obtain a 20‐fold higher linear detection range than the normal diphase system. Other biomolecules can also be determined using this triphase technique, and the triphase design strategy offers a new route to address the gas deficiency problem in catalytic reactions that involve gas consumption.
- 5 December 2022
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 38 (50) , 15796-15803
High-Performance Photoelectrochemical Enzymatic Bioanalysis Based on a 3D Porous CuxO@TiO2 Film with a Solid–Liquid–Air Triphase Interface
The accurate detection of H2O2 is crucial in oxidase-based cathodic photoelectrochemical enzymatic bioanalysis but will be easily compromised in the conventional photoelectrode-electrolyte diphase system due to the fluctuation of oxygen levels and the similar reduction potential between oxygen and H2O2. Herein, a solid-liquid-air triphase bio-photocathode based on a superhydrophobic three-dimensional (3D) porous micro-nano-hierarchical structured CuxO@TiO2 film that was constructed by controlling the wettability of the electrode surface is reported. The triphase photoelectrochemical system ensures an oxygen-rich interface microenvironment with constant and sufficiently high oxygen concentration. Moreover, the 3D porous micro-nano-hierarchical structures possess abundant active catalytic sites and a multidimensional electron transport pathway. The synergistic effect of the improved oxygen supply and the photoelectrode architecture greatly stabilizes and enhances the kinetics of the enzymatic reaction and H2O2 cathodic reaction, resulting in a 60-fold broader linear detection range and a higher accuracy compared with the conventional solid-liquid diphase system.
- 5 December 2022
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 38 (50) , 15796-15803
High-Performance Photoelectrochemical Enzymatic Bioanalysis Based on a 3D Porous CuxO@TiO2 Film with a Solid–Liquid–Air Triphase Interface
The accurate detection of H2O2 is crucial in oxidase-based cathodic photoelectrochemical enzymatic bioanalysis but will be easily compromised in the conventional photoelectrode-electrolyte diphase system due to the fluctuation of oxygen levels and the similar reduction potential between oxygen and H2O2. Herein, a solid-liquid-air triphase bio-photocathode based on a superhydrophobic three-dimensional (3D) porous micro-nano-hierarchical structured CuxO@TiO2 film that was constructed by controlling the wettability of the electrode surface is reported. The triphase photoelectrochemical system ensures an oxygen-rich interface microenvironment with constant and sufficiently high oxygen concentration. Moreover, the 3D porous micro-nano-hierarchical structures possess abundant active catalytic sites and a multidimensional electron transport pathway. The synergistic effect of the improved oxygen supply and the photoelectrode architecture greatly stabilizes and enhances the kinetics of the enzymatic reaction and H2O2 cathodic reaction, resulting in a 60-fold broader linear detection range and a higher accuracy compared with the conventional solid-liquid diphase system.
- 11 November 2022
- Published by Wiley in Advanced Functional Materials
- Vol. 33 (4)
Oxygen Vacancy‐Mediated Catalysts toward Selective H2O2 Reduction in Cellular Environment
Abnormal hydrogen peroxide (H2O2) levels in the cellular environment are closely related to cell dysfunction and serious diseases. Thus, selective and sensitive H2O2 detections are urgently needed for clinical diagnosis and therapy. Herein, via surface defect engineering, an oxygen‐tolerant electrocatalyst based on tin oxide for selective H2O2 reduction and detection with exceptional stability and activity is designed and developed. When introduced at an appropriate level (≈5.3%), surface oxygen vacancies help lower the charge transfer resistance for enhancing the H2O2 reduction reaction, while maintain the weak oxygen (O2) adsorption, which enables a constant H2O2 reduction (sensing) response in the electrolyte at variable oxygen levels. Moreover, the tin oxide‐based assay system exhibits outstanding stability over a wide pH range of 4–9, as well as selectivity in the presence of interferent endogenous and exogenous electroactive species, which is suitable for trace H2O2 monitoring secreted from NB4 cells, a model cancer cell. The oxygen vacancy‐mediated tin oxide achieves the highest stability as well as high selectivity compared to reported electrochemical probes for specific H2O2 detection in biological environments, with the potential for biological and biomedical applications.
- 11 November 2022
- Published by Wiley in Advanced Functional Materials
- Vol. 33 (4)
Oxygen Vacancy‐Mediated Catalysts toward Selective H2O2 Reduction in Cellular Environment
Abnormal hydrogen peroxide (H2O2) levels in the cellular environment are closely related to cell dysfunction and serious diseases. Thus, selective and sensitive H2O2 detections are urgently needed for clinical diagnosis and therapy. Herein, via surface defect engineering, an oxygen‐tolerant electrocatalyst based on tin oxide for selective H2O2 reduction and detection with exceptional stability and activity is designed and developed. When introduced at an appropriate level (≈5.3%), surface oxygen vacancies help lower the charge transfer resistance for enhancing the H2O2 reduction reaction, while maintain the weak oxygen (O2) adsorption, which enables a constant H2O2 reduction (sensing) response in the electrolyte at variable oxygen levels. Moreover, the tin oxide‐based assay system exhibits outstanding stability over a wide pH range of 4–9, as well as selectivity in the presence of interferent endogenous and exogenous electroactive species, which is suitable for trace H2O2 monitoring secreted from NB4 cells, a model cancer cell. The oxygen vacancy‐mediated tin oxide achieves the highest stability as well as high selectivity compared to reported electrochemical probes for specific H2O2 detection in biological environments, with the potential for biological and biomedical applications.
- 25 October 2022
- Published by American Chemical Society (ACS) in ACS Catalysis
- Vol. 12 (21) , 13690-13696
Liquid–Liquid–Solid Triphase Interface Microenvironment Mediates Efficient Photocatalysis
- 25 October 2022
- Published by American Chemical Society (ACS) in ACS Catalysis
- Vol. 12 (21) , 13690-13696
Liquid–Liquid–Solid Triphase Interface Microenvironment Mediates Efficient Photocatalysis