Raman Pasledni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Raman Pasledni has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Krzysztof Zieliński
Department of Modeling and Supporting of Internal Organs Functions, Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
3 shared publications - Marek Darowski
Department of Modeling and Supporting of Internal Organs Functions, Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, ul. Ks. Trojdena 4, 02-109 Warsaw, Poland
3 shared publications - Tomasz Urbankowski
Department of Modeling and Supporting of Internal Organs Functions, Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
3 shared publications - Barbara Stankiewicz
Department of Modeling and Supporting of Internal Organs Functions, Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
2 shared publications - Krzysztof Jakub Pałko
Department of Modeling and Supporting of Internal Organs Functions, Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
2 shared publications - Maciej Kozarski
Department of Modeling and Supporting of Internal Organs Functions, Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
2 shared publications
Latest Publications
- Open Access
- 27 October 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-13
Model-Based Elastic–Resistive Partitioning of Inspiratory Mechanical Power During Conventional and Energy-Targeted Ventilation in a Hybrid Respiratory Simulator
Purpose: Mechanical power provides a global description of the energetic load imposed by mechanical ventilation, but similar total values may reflect different elastic and resistive components. This study applied a model-based framework to characterize elastic and resistive inspiratory mechanical power during conventional and investigational energy-targeted ventilation in a hybrid respiratory simulator. Methods: An experimental bench study was performed using a hybrid respiratory simulator coupled with a prototype ventilator. Four respiratory system conditions were simulated: normal mechanics and mild, moderate, and severe ARDS-like elastic impairment. Compliance was reduced from 60 to 30 mL/cmH 2 O, while resistance was kept constant at 10 cmH 2 O/L/s. Volume-controlled, pressure-controlled, and mechanical power-controlled ventilation were evaluated at respiratory rates of 10, 15, and 20 breaths/min. Maximal and mean elastic and resistive inspiratory mechanical power were assessed. Results: Ventilation mode significantly affected all analyzed power components. Mechanical power-controlled ventilation produced the lowest pooled maximal elastic power, with reductions of 16.2% versus volume-controlled ventilation and 24.3% versus pressure-controlled ventilation (both p < 0.001). This effect was most evident at lower respiratory rates and under more severe elastic impairment. For resistive power, pressure-controlled ventilation produced the highest values, volume-controlled ventilation the lowest, and mechanical power-controlled ventilation remained intermediate. Conclusion: Component-level analysis revealed ventilation mode-dependent differences in inspiratory energy transfer that were not captured by total mechanical power alone.
- 27 October 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-13
Open AccessModel-Based Elastic–Resistive Partitioning of Inspiratory Mechanical Power During Conventional and Energy-Targeted Ventilation in a Hybrid Respiratory Simulator
Purpose: Mechanical power provides a global description of the energetic load imposed by mechanical ventilation, but similar total values may reflect different elastic and resistive components. This study applied a model-based framework to characterize elastic and resistive inspiratory mechanical power during conventional and investigational energy-targeted ventilation in a hybrid respiratory simulator. Methods: An experimental bench study was performed using a hybrid respiratory simulator coupled with a prototype ventilator. Four respiratory system conditions were simulated: normal mechanics and mild, moderate, and severe ARDS-like elastic impairment. Compliance was reduced from 60 to 30 mL/cmH 2 O, while resistance was kept constant at 10 cmH 2 O/L/s. Volume-controlled, pressure-controlled, and mechanical power-controlled ventilation were evaluated at respiratory rates of 10, 15, and 20 breaths/min. Maximal and mean elastic and resistive inspiratory mechanical power were assessed. Results: Ventilation mode significantly affected all analyzed power components. Mechanical power-controlled ventilation produced the lowest pooled maximal elastic power, with reductions of 16.2% versus volume-controlled ventilation and 24.3% versus pressure-controlled ventilation (both p < 0.001). This effect was most evident at lower respiratory rates and under more severe elastic impairment. For resistive power, pressure-controlled ventilation produced the highest values, volume-controlled ventilation the lowest, and mechanical power-controlled ventilation remained intermediate. Conclusion: Component-level analysis revealed ventilation mode-dependent differences in inspiratory energy transfer that were not captured by total mechanical power alone.
- Open Access
- 29 April 2026
- Published by European Respiratory Society (ERS) in European Respiratory Review
- Vol. 35 (180) , 250283
The role of mechanical power in lung ventilation for the prevention of ventilator-induced lung injury: a narrative review
Ventilator-induced lung injury continues to limit outcomes in patients with acute respiratory failure despite established lung-protective strategies. Mechanical power, the rate of energy transfer from the ventilator to the respiratory system, has emerged as an integrative index of ventilator-induced stress. Experimental studies indicate that cumulative and dissipated energy, rather than isolated pressures or volumes, drive lung injury. Observational and registry data consistently link higher mechanical power with increased mortality in acute respiratory distress syndrome and mixed intensive care unit populations, with thresholds of ∼16–18 J·min −1 associated with increased risk. Normalised indices ( e.g. mechanical power per predicted body weight or per compliance) often outperform absolute mechanical power as predictors of outcome. Strategies to minimise mechanical power include individualised positive end-expiratory pressure titration, driving pressure limitation, and an optimised respiratory rate. Complementing traditional physiological analysis, this review highlights the emerging role of technological integration, specifically closed-loop ventilation and artificial intelligence-driven prediction models, as essential tools to bridge the gap between theoretical mechanical power concepts and bedside application. Mechanical power provides a unifying physiological framework that integrates volume, pressure, flow and frequency into a single descriptive measure of ventilatory load. While higher mechanical power is consistently associated with worse outcomes, current evidence does not support titrating ventilation to pre-defined numerical power thresholds, and prospective randomised trials are required to determine whether mechanical power-informed strategies improve patient-centred outcomes. Mechanical power should therefore be regarded as a contextual physiological descriptor rather than a standalone therapeutic target.
- 29 April 2026
- Published by European Respiratory Society (ERS) in European Respiratory Review
- Vol. 35 (180) , 250283
Open AccessThe role of mechanical power in lung ventilation for the prevention of ventilator-induced lung injury: a narrative review
Ventilator-induced lung injury continues to limit outcomes in patients with acute respiratory failure despite established lung-protective strategies. Mechanical power, the rate of energy transfer from the ventilator to the respiratory system, has emerged as an integrative index of ventilator-induced stress. Experimental studies indicate that cumulative and dissipated energy, rather than isolated pressures or volumes, drive lung injury. Observational and registry data consistently link higher mechanical power with increased mortality in acute respiratory distress syndrome and mixed intensive care unit populations, with thresholds of ∼16–18 J·min −1 associated with increased risk. Normalised indices ( e.g. mechanical power per predicted body weight or per compliance) often outperform absolute mechanical power as predictors of outcome. Strategies to minimise mechanical power include individualised positive end-expiratory pressure titration, driving pressure limitation, and an optimised respiratory rate. Complementing traditional physiological analysis, this review highlights the emerging role of technological integration, specifically closed-loop ventilation and artificial intelligence-driven prediction models, as essential tools to bridge the gap between theoretical mechanical power concepts and bedside application. Mechanical power provides a unifying physiological framework that integrates volume, pressure, flow and frequency into a single descriptive measure of ventilatory load. While higher mechanical power is consistently associated with worse outcomes, current evidence does not support titrating ventilation to pre-defined numerical power thresholds, and prospective randomised trials are required to determine whether mechanical power-informed strategies improve patient-centred outcomes. Mechanical power should therefore be regarded as a contextual physiological descriptor rather than a standalone therapeutic target.
- 20 November 2025
- Published by Elsevier in Respiratory Medicine
- Vol. 250, 108525
Mechanical power in mechanical ventilation and its association with ventilator-induced lung injury: A systematic review
- 20 November 2025
- Published by Elsevier in Respiratory Medicine
- Vol. 250, 108525
Mechanical power in mechanical ventilation and its association with ventilator-induced lung injury: A systematic review
- Open Access
- 23 May 2024
- Published by Elsevier in Journal of Biomechanics
- Vol. 170, 112173
The hybrid (physical-computational) cardiovascular simulator to study valvular diseases
- 23 May 2024
- Published by Elsevier in Journal of Biomechanics
- Vol. 170, 112173
Open AccessThe hybrid (physical-computational) cardiovascular simulator to study valvular diseases
- 9 September 2021
- Published by Springer Nature
- p. 98-107
Hybrid Cardiovascular Simulator - An Application for the Mechanical Assistance by an Intra-aortic Balloon Pump
- 9 September 2021
- Published by Springer Nature
- p. 98-107
Hybrid Cardiovascular Simulator - An Application for the Mechanical Assistance by an Intra-aortic Balloon Pump