Jing Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jing Liu has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Alexey Samsonov
University of Wisconsin Madison Wisconsin USA
1 shared publication Oliver Wieben
Department of Medical Physics, University of Wisconsin-Madison, Wisconsin, USA
1 shared publication- Scott Brian Reeder
Department of Radiology University of Wisconsin–Madison Madison Wisconsin USA
1 shared publication Walter F. Block
Department of Medical Physics, University of Wisconsin-Madison, Wisconsin, USA
1 shared publicationYoungkyoo Jung
Department of Radiology, University of California San Diego, California, USA
1 shared publication
Latest Publications
- Open Access
- 22 July 2010
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 32 (2) , 434-440
Single breathhold cardiac CINE imaging with multi‐echo three‐dimensional hybrid radial SSFP acquisition
Purpose: To achieve single breathhold whole heart cardiac CINE imaging with improved spatial resolution and temporal resolution by using a multi-echo three-dimensional (3D) hybrid radial SSFP acquisition. Materials and Methods: Multi-echo 3D hybrid radial SSFP acquisitions were used to acquire cardiac CINE imaging within a single breathhold. An optimized interleaving scheme was developed for view ordering throughout the cardiac cycle. Results: Whole heart short axis views were acquired with a spatial resolution of 1.3 × 1.3 × 8.0 mm3 and temporal resolution of 45 ms, within a single 17 s breathhold. The technique was validated on eight healthy volunteers by measuring the left ventricular volume throughout the cardiac cycle and comparing with the conventional 2D multiple breathhold technique. The left ventricle functional measurement bias of our proposed 3D technique from the conventional 2D technique: end diastolic volume −3.3 mL ± 13.7 mL, end systolic volume 1.4 mL ± 6.1 mL, and ejection fraction −1.7% ± 4.3%, with high correlations 0.94, 0.97, and 0.91, accordingly. Conclusion: A multi-echo 3D hybrid radial SSFP acquisition was developed to allow for a whole heart cardiac CINE exam in a single breathhold. Cardiac function measurements in volunteers compared favorably with the standard multiple breathhold exams. J. Magn. Reson. Imaging 2010;32:434–440.
- 22 July 2010
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 32 (2) , 434-440
Open AccessSingle breathhold cardiac CINE imaging with multi‐echo three‐dimensional hybrid radial SSFP acquisition
Purpose: To achieve single breathhold whole heart cardiac CINE imaging with improved spatial resolution and temporal resolution by using a multi-echo three-dimensional (3D) hybrid radial SSFP acquisition. Materials and Methods: Multi-echo 3D hybrid radial SSFP acquisitions were used to acquire cardiac CINE imaging within a single breathhold. An optimized interleaving scheme was developed for view ordering throughout the cardiac cycle. Results: Whole heart short axis views were acquired with a spatial resolution of 1.3 × 1.3 × 8.0 mm3 and temporal resolution of 45 ms, within a single 17 s breathhold. The technique was validated on eight healthy volunteers by measuring the left ventricular volume throughout the cardiac cycle and comparing with the conventional 2D multiple breathhold technique. The left ventricle functional measurement bias of our proposed 3D technique from the conventional 2D technique: end diastolic volume −3.3 mL ± 13.7 mL, end systolic volume 1.4 mL ± 6.1 mL, and ejection fraction −1.7% ± 4.3%, with high correlations 0.94, 0.97, and 0.91, accordingly. Conclusion: A multi-echo 3D hybrid radial SSFP acquisition was developed to allow for a whole heart cardiac CINE exam in a single breathhold. Cardiac function measurements in volunteers compared favorably with the standard multiple breathhold exams. J. Magn. Reson. Imaging 2010;32:434–440.