Single breathhold cardiac CINE imaging with multi‐echo three‐dimensional hybrid radial SSFP acquisition
Open Access
- 22 July 2010
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 32 (2) , 434-440
Abstract
Purpose: To achieve single breathhold whole heart cardiac CINE imaging with improved spatial resolution and temporal resolution by using a multi-echo three-dimensional (3D) hybrid radial SSFP acquisition. Materials and Methods: Multi-echo 3D hybrid radial SSFP acquisitions were used to acquire cardiac CINE imaging within a single breathhold. An optimized interleaving scheme was developed for view ordering throughout the cardiac cycle. Results: Whole heart short axis views were acquired with a spatial resolution of 1.3 × 1.3 × 8.0 mm3 and temporal resolution of 45 ms, within a single 17 s breathhold. The technique was validated on eight healthy volunteers by measuring the left ventricular volume throughout the cardiac cycle and comparing with the conventional 2D multiple breathhold technique. The left ventricle functional measurement bias of our proposed 3D technique from the conventional 2D technique: end diastolic volume −3.3 mL ± 13.7 mL, end systolic volume 1.4 mL ± 6.1 mL, and ejection fraction −1.7% ± 4.3%, with high correlations 0.94, 0.97, and 0.91, accordingly. Conclusion: A multi-echo 3D hybrid radial SSFP acquisition was developed to allow for a whole heart cardiac CINE exam in a single breathhold. Cardiac function measurements in volunteers compared favorably with the standard multiple breathhold exams. J. Magn. Reson. Imaging 2010;32:434–440.Keywords
This publication has 26 references indexed in Scilit:
- 3D diffusion tensor MRI with isotropic resolution using a steady‐state radial acquisitionJournal of Magnetic Resonance Imaging, 2009
- Inflow quantification in three‐dimensional cardiovascular MR imagingJournal of Magnetic Resonance Imaging, 2008
- Four‐dimensional single breathhold magnetic resonance imaging using kt‐BLAST enables reliable assessment of left‐ and right‐ventricular volumes and massJournal of Magnetic Resonance Imaging, 2007
- Consistent non‐cartesian off‐axis MRI quality: Calibrating and removing multiple sources of demodulation phase errorsMagnetic Resonance in Medicine, 2006
- Flow compensation in balanced SSFP sequencesMagnetic Resonance in Medicine, 2005
- Analysis and compensation of eddy currents in balanced SSFPMagnetic Resonance in Medicine, 2005
- Rapid fat‐suppressed isotropic steady‐state free precession imaging using true 3D multiple‐half‐echo projection reconstructionMagnetic Resonance in Medicine, 2005
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001
- Homodyne detection in magnetic resonance imagingIEEE Transactions on Medical Imaging, 1991
- An analysis of fast imaging sequences with steady‐state transverse magnetization refocusingMagnetic Resonance in Medicine, 1988