Klaus Lehner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Klaus Lehner has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Johann Kollegger
Technische Universität Wien Institut für Tragkonstruktionen, Forschungsbereich Stahlbeton‐ und Massivbau Karlsplatz 13/212‐2 1040 Wien
1 shared publication - Josef Simader
Grund- Pfahl- und Sonderbau GmbH, Industriestraße 27a, Himberg 2325, Austria
1 shared publication - Susanne Gmainer
TU Vienna – Institute for Structural Engineering, Karlsplatz 13/212-2, Vienna 1040, Austria
1 shared publication
Latest Publications
- 1 March 2012
- Published by Wiley in Structural Concrete
- Vol. 13 (1) , 42-50
Ultimate strength of curved strand tendons
In a bridge construction process, where large concrete elements are rotated with the aid of strand lifting units (lowering of arch halves, balanced lift method), the tendons have to be deviated over saddles with small radii of curvature. Since information on the ultimate strength of curved strand tendons was not available at the time, a test programme was carried out in order to determine the ultimate strength as a function of radius of curvature (R = 0.5 m, R = 1.0 m, R = 3.0 m, straight tendons), number of strands (1 to 55) and type of strand (0.5″ and 0.6″). The results of the full scale experiments showed almost no decrease in efficiency with regard to single strand tendons and only moderate losses regarding multistrand tendons. Based on the experimental results and a biaxial failure criterion, an analytical model was developed which is able to predict the ultimate strength of curved tendons.
- 1 March 2012
- Published by Wiley in Structural Concrete
- Vol. 13 (1) , 42-50
Ultimate strength of curved strand tendons
In a bridge construction process, where large concrete elements are rotated with the aid of strand lifting units (lowering of arch halves, balanced lift method), the tendons have to be deviated over saddles with small radii of curvature. Since information on the ultimate strength of curved strand tendons was not available at the time, a test programme was carried out in order to determine the ultimate strength as a function of radius of curvature (R = 0.5 m, R = 1.0 m, R = 3.0 m, straight tendons), number of strands (1 to 55) and type of strand (0.5″ and 0.6″). The results of the full scale experiments showed almost no decrease in efficiency with regard to single strand tendons and only moderate losses regarding multistrand tendons. Based on the experimental results and a biaxial failure criterion, an analytical model was developed which is able to predict the ultimate strength of curved tendons.