S. A. Karrab
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
S. A. Karrab has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- M. A. Doheim
Mining and Metallurgical Engineering Department, Assiut University, Assiut71516, Egypt
3 shared publications - Mohammed S. Aboraia
Mining and Metallurgical Engineering Department, Faculty of Engineering, Assiut University, Assiut
3 shared publications - Shemy M. Ahmed
Mechanical Engineering Department, Faculty of Engineering, Majmaah University, North Riyadh, Kingdom of Saudi Arabia
3 shared publications - Ahmed Abouel Kasem Mohamad
King Abdulaziz University Department of Mechanical Engineering, Faculty of Eng.-Rabigh P. O. Box 344, Rabigh 21911 , Saudi Arabia
1 shared publication M. A. Doheim
Mining and Metallurgical Engineering Department, Assiut University, Assiut 71516, Egypt
1 shared publicationMohammed S. Aboraia
Mining and Metallurgical Engineering Department, Assiut University, Assiut 71516, Egypt
1 shared publication
Latest Publications
- 16 July 2021
- Published by ASME International in Journal of Tribology
- Vol. 144 (4) , 1-14
The Limited Role of Pit Formed by Microjet in Evolution of Cavitation Erosion in the Incubation Period
Stepwise cavitation erosion is used to study pits formed by microjets. The aim is to determine the role of the pit in the development of cavitation erosion damage, including geometrical features of the pitted area and pit counting. The study also identified the dominant feature in the development of cavitation damage. We used a vibratory cavitation apparatus to perform cavitation erosion damage on a stainless steel, SUS 304, in tap water with scanning electron microscopy (SEM) at 5-min intervals from t = 0 min to t = 45 min. We then analyzed and characterized the pits formed by impacting the surface with a microjet. These results showed that individual pits and clusters of pits are characterized by a black spot surrounded by plastic deformation, and both are irregular in shape. This suggests that the microjet is hitting the wear surface in an oblique direction. Over the course of the test time, neither the shape nor the size of the microjet pits and their clusters change; pit diameters approximately 2 μm or less. The area of pits and their clusters does not exceed 1% of the worn surface. All these features demonstrate that the pit and its clusters do not impact the evolution of cavitation damage. Our results also indicated that slip bands were caused by a shock wave. Slip bands are large (>10 μm) and account for about 30% of the wear surface. This confirms that slip bands are predominantly responsible for the development of cavitation; the predominant cavitation mechanism is fatigue due to multiple shock waves.
- 16 July 2021
- Published by ASME International in Journal of Tribology
- Vol. 144 (4) , 1-14
The Limited Role of Pit Formed by Microjet in Evolution of Cavitation Erosion in the Incubation Period
Stepwise cavitation erosion is used to study pits formed by microjets. The aim is to determine the role of the pit in the development of cavitation erosion damage, including geometrical features of the pitted area and pit counting. The study also identified the dominant feature in the development of cavitation damage. We used a vibratory cavitation apparatus to perform cavitation erosion damage on a stainless steel, SUS 304, in tap water with scanning electron microscopy (SEM) at 5-min intervals from t = 0 min to t = 45 min. We then analyzed and characterized the pits formed by impacting the surface with a microjet. These results showed that individual pits and clusters of pits are characterized by a black spot surrounded by plastic deformation, and both are irregular in shape. This suggests that the microjet is hitting the wear surface in an oblique direction. Over the course of the test time, neither the shape nor the size of the microjet pits and their clusters change; pit diameters approximately 2 μm or less. The area of pits and their clusters does not exceed 1% of the worn surface. All these features demonstrate that the pit and its clusters do not impact the evolution of cavitation damage. Our results also indicated that slip bands were caused by a shock wave. Slip bands are large (>10 μm) and account for about 30% of the wear surface. This confirms that slip bands are predominantly responsible for the development of cavitation; the predominant cavitation mechanism is fatigue due to multiple shock waves.
- 31 July 2015
- Published by Wiley
- p. 87-97
Effect of Electroless Ni‐Co‐P and Co‐P Coatings on Cavitation Erosion Resistance
- 31 July 2015
- Published by Wiley
- p. 87-97
Effect of Electroless Ni‐Co‐P and Co‐P Coatings on Cavitation Erosion Resistance
- Open Access
- 1 September 2013
- Published by Egyptian Knowledge Bank in JES. Journal of Engineering Sciences
- Vol. 41 (5) , 1989-2011
EFFECT OF HEAT TREATMENT AND BATH COMPOSITION OF ELECTROLESS NICKEL-PLATING ON CAVITATION EROSION RESISTANCE
Electroless Nickel-Phosphorus coatings have had a lot of interest in various industries due to outstanding characteristics. Some of the highlighted characteristics of electroless Ni-P coatings are superior corrosion and wear resistance. But the effectiveness of electroless Ni-P coating in resisting cavitation damage is not studied so well and is not so clear. In the present investigation, electroless Ni-P coatings were prepared at various conditions including the type of bath, heat treatment temperature and plating solutions composition. The properties of electroless Ni-P coatings were characterized using X-ray diffraction technique (XRD), energy dispersive X- ray (EDX) optical microscope, and microhardness tester. The cavitation erosion tests were carried out to study the effect bath type, heat treatment temperature and plating solutions composition on the deposit coatings. The XRD results indicate that the as-deposit had crystalline structure for alkaline bath and amorphous structure for acid bath. Heat treatment of the coatings produced mixture of polycrystalline phases. The thickness of deposit films depend on the bath type and concentration and were the least for alkaline baths. Maximum hardness of heat treated samples was found to depend on the solution composition and occurs at temperature 300 °C and 400°C. The highest erosion resistance of the coatings was observed for the heat treated deposits at temperature of 650 °C, and comes to the fore the coatings formed in alkaline baths followed by that formed in acid baths. The best erosion resistance for deposits formed in alkaline baths is attributed to the small thickness and crystalline structure. The results showed also that the cavitation erosion resistance is independent on surface hardness.
- 1 September 2013
- Published by Egyptian Knowledge Bank in JES. Journal of Engineering Sciences
- Vol. 41 (5) , 1989-2011
Open AccessEFFECT OF HEAT TREATMENT AND BATH COMPOSITION OF ELECTROLESS NICKEL-PLATING ON CAVITATION EROSION RESISTANCE
Electroless Nickel-Phosphorus coatings have had a lot of interest in various industries due to outstanding characteristics. Some of the highlighted characteristics of electroless Ni-P coatings are superior corrosion and wear resistance. But the effectiveness of electroless Ni-P coating in resisting cavitation damage is not studied so well and is not so clear. In the present investigation, electroless Ni-P coatings were prepared at various conditions including the type of bath, heat treatment temperature and plating solutions composition. The properties of electroless Ni-P coatings were characterized using X-ray diffraction technique (XRD), energy dispersive X- ray (EDX) optical microscope, and microhardness tester. The cavitation erosion tests were carried out to study the effect bath type, heat treatment temperature and plating solutions composition on the deposit coatings. The XRD results indicate that the as-deposit had crystalline structure for alkaline bath and amorphous structure for acid bath. Heat treatment of the coatings produced mixture of polycrystalline phases. The thickness of deposit films depend on the bath type and concentration and were the least for alkaline baths. Maximum hardness of heat treated samples was found to depend on the solution composition and occurs at temperature 300 °C and 400°C. The highest erosion resistance of the coatings was observed for the heat treated deposits at temperature of 650 °C, and comes to the fore the coatings formed in alkaline baths followed by that formed in acid baths. The best erosion resistance for deposits formed in alkaline baths is attributed to the small thickness and crystalline structure. The results showed also that the cavitation erosion resistance is independent on surface hardness.
- 1 January 2012
- Published by ASME International in Journal of Tribology
- Vol. 134 (1) , 011602
Study of Cavitation Erosion Pits on 1045 Carbon Steel Surface in Corrosive Waters
Cavitation erosion resistance of steels is important in many applications. The investigation of such resistance, under different conditions, should be very useful. Cavitation erosion tests were carried out on carbon steel AISI-1045 using an ultrasonic induced cavitation facility. Cavitation erosion pits and their effect on the localized corrosion were investigated in detail in three different corrosive media: distilled water, tap water, and 3% NaCl water.The results of the investigation using SEM indicated the formation of three types of pits on cavitating specimen surfaces: corrosion pits, erosion pits, and erosion-corrosion pits. The corrosion pits have different shapes, however, the lamellar structure is the dominant structure, and has a large size of about 100 μm. The erosion pits that were formed by the cavitation microjet impacts have sizes of a few micrometers. The erosion-corrosion pits were similar to the corrosion pits, except the erosion pits formed on the corrosion pit surface due to dissolution. The eroded surface removal was the largest in the case of saline water.
- 1 January 2012
- Published by ASME International in Journal of Tribology
- Vol. 134 (1) , 011602
Study of Cavitation Erosion Pits on 1045 Carbon Steel Surface in Corrosive Waters
Cavitation erosion resistance of steels is important in many applications. The investigation of such resistance, under different conditions, should be very useful. Cavitation erosion tests were carried out on carbon steel AISI-1045 using an ultrasonic induced cavitation facility. Cavitation erosion pits and their effect on the localized corrosion were investigated in detail in three different corrosive media: distilled water, tap water, and 3% NaCl water.The results of the investigation using SEM indicated the formation of three types of pits on cavitating specimen surfaces: corrosion pits, erosion pits, and erosion-corrosion pits. The corrosion pits have different shapes, however, the lamellar structure is the dominant structure, and has a large size of about 100 μm. The erosion pits that were formed by the cavitation microjet impacts have sizes of a few micrometers. The erosion-corrosion pits were similar to the corrosion pits, except the erosion pits formed on the corrosion pit surface due to dissolution. The eroded surface removal was the largest in the case of saline water.
- 24 December 2011
- Published by Springer Nature in Tribology Letters
- Vol. 45 (3) , 437-444
Investigation of the Ring Area Formed Around Cavitation Erosion Pits on the Surface of Carbon Steel
- 24 December 2011
- Published by Springer Nature in Tribology Letters
- Vol. 45 (3) , 437-444
Investigation of the Ring Area Formed Around Cavitation Erosion Pits on the Surface of Carbon Steel