Humberto Campanella
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Humberto Campanella has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Jaume Esteve
Department of Micro and Nanoengineering, Instituto de Microelectrónica de Barcelona IMB-CNM (CSIC), Campus UAB Bellaterra, 08193 Barcelona, Spain
3 shared publications - Arantxa Uranga
Department of Electronics Engineering, Universitat Autnoma de Barcelona, Barcelona, Spain
2 shared publications - Nuria Barniol
Department of Electronics Engineering, Universitat Autnoma de Barcelona, Barcelona, Spain
2 shared publications - Albert Romano-Rodriguez
Department of Electronic and Biomedical Engineering, University of Barcelona, 08028 Barcelona, Spain
1 shared publication - Gabriel Abadal
Departament d'Enginyeria Electrònica, Universitat Autònoma de Barcelona 1 , Bellaterra 08193, Spain
1 shared publication - Héctor Guerrero
Instituto Nacional de Técnica Aeroespacial (INTA)
1 shared publication
Latest Publications
- 16 February 2009
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 1 (3) , 527-531
Focused-Ion-Beam-Assisted Magnet Fabrication and Manipulation for Magnetic Field Detection Applications
A focused-ion-beam-assisted technique intended for ultrasmall, hard-magnet fabrication has been developed. By means of ion-beam-induced milling and deposition, reduced-size NdFeB magnets were extracted from a macroscopic quarry and bonded to the surface of a thin-film bulk acoustic resonator (FBAR). Electrical characterization of the FBAR before and after bonding of the magnet was carried out, thus observing both a downshifting of the resonance frequency and a reduction of the quality factor of the resonator. The magnetic behavior of the nanomagnet has been confirmed by means of magnetometry measurements based on atomic force microscopy.
- 16 February 2009
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 1 (3) , 527-531
Focused-Ion-Beam-Assisted Magnet Fabrication and Manipulation for Magnetic Field Detection Applications
A focused-ion-beam-assisted technique intended for ultrasmall, hard-magnet fabrication has been developed. By means of ion-beam-induced milling and deposition, reduced-size NdFeB magnets were extracted from a macroscopic quarry and bonded to the surface of a thin-film bulk acoustic resonator (FBAR). Electrical characterization of the FBAR before and after bonding of the magnet was carried out, thus observing both a downshifting of the resonance frequency and a reduction of the quality factor of the resonator. The magnetic behavior of the nanomagnet has been confirmed by means of magnetometry measurements based on atomic force microscopy.
- 19 November 2007
- Published by Wiley in Microwave and Optical Technology Letters
- Vol. 50 (1) , 4-7
Automated on‐wafer extraction of equivalent‐circuit parameters in thin‐film bulk acoustic wave resonators and substrate
On‐wafer parameter extraction in thin‐film bulk acoustic wave resonator (FBAR) embedded on its substrate is performed. The extraction algorithm implements a multistep least‐squares optimization strategy, obtaining the equivalent‐circuit parameters of both FBAR and its substrate from experimental data. Compared with previous works, the algorithm enables for model‐based de‐embedding of the FBAR parameters. © 2007 Wiley Periodicals, Inc. Microwave Opt Technol Lett 50: 4–7, 2008; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.22986
- 19 November 2007
- Published by Wiley in Microwave and Optical Technology Letters
- Vol. 50 (1) , 4-7
Automated on‐wafer extraction of equivalent‐circuit parameters in thin‐film bulk acoustic wave resonators and substrate
On‐wafer parameter extraction in thin‐film bulk acoustic wave resonator (FBAR) embedded on its substrate is performed. The extraction algorithm implements a multistep least‐squares optimization strategy, obtaining the equivalent‐circuit parameters of both FBAR and its substrate from experimental data. Compared with previous works, the algorithm enables for model‐based de‐embedding of the FBAR parameters. © 2007 Wiley Periodicals, Inc. Microwave Opt Technol Lett 50: 4–7, 2008; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.22986
- Open Access
- 17 July 2006
- Published by AIP Publishing in Applied Physics Letters
- Vol. 89 (3) , 033507
Localized and distributed mass detectors with high sensitivity based on thin-film bulk acoustic resonators
A mass sensor based on thin-film bulk acoustic resonator, intended for biomolecular applications, is presented. The thin film is a (002) AlN membrane, sputtered over on a (001) Si wafer, and released by surface micromachining of silicon. Two experiments are proposed to test the mass sensing performance of the resonators: (a) distributed loading with a film by means of physical vapor deposition and (b) localized mass growing of a composite using focused-ion-beam-assisted deposition, both on the top electrode. For the distributed and localized cases, the minimum detectable mass changes are and , respectively.- 17 July 2006
- Published by AIP Publishing in Applied Physics Letters
- Vol. 89 (3) , 033507
Open AccessLocalized and distributed mass detectors with high sensitivity based on thin-film bulk acoustic resonators
A mass sensor based on thin-film bulk acoustic resonator, intended for biomolecular applications, is presented. The thin film is a (002) AlN membrane, sputtered over on a (001) Si wafer, and released by surface micromachining of silicon. Two experiments are proposed to test the mass sensing performance of the resonators: (a) distributed loading with a film by means of physical vapor deposition and (b) localized mass growing of a composite using focused-ion-beam-assisted deposition, both on the top electrode. For the distributed and localized cases, the minimum detectable mass changes are and , respectively.