Wei Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wei Liu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Kohju Ikago
Earthquake Engineering Laboratory, , , Sendai, Japan
8 shared publications Jiang Liu
5 shared publications- Yukun DU
Department of Architecture, The University of Tokyo, Tokyo 112-0033, Japan
3 shared publications Jing Xie
2 shared publicationsQiang Xie
2 shared publications- Wai Kei Ao
Department of Civil Engineering, the Hong Kong Polytechnic University, Hung Hom, Hong Kong
2 shared publications
Latest Publications
- Open Access
Seismic Response Amplification Mechanisms and Base-Isolation Retrofit Evaluation of a 500 kV Three-Phase Transformer with Steel Supports
The effects of steel supports on the dynamic characteristics and seismic demands of large three-phase power transformers remain insufficiently quantified. A three-dimensional finite-element model of a 500 kV three-phase transformer was developed to compare configurations without steel support (NS) and with steel support (WS). Modal characteristics and seismic bushing responses were evaluated under seven three-component ground motions. Frequency-response characteristics and global tank rotations were then analyzed, and a double friction pendulum (DFP) base-isolation retrofit was assessed. The lowest natural frequency of the WS model was 1.47 Hz, lower than the 1.84 Hz obtained for the NS model. For the representative X-direction response of high-voltage bushing A, the dominant low-frequency peak of the frequency-response function shifted from approximately 1.89 to 1.64 Hz, while its magnitude increased from approximately 8 to 19. The mean peak maximum principal tensile stress at the root of bushing A increased by 83.1%. The WS model also exhibited greater tank rocking and torsional responses, whose peaks were positively associated with the peak root stresses of bushings A and B. For representative high-voltage bushing B, the DFP retrofit achieved a mean isolation efficiency of approximately 60%. These results elucidate the mechanisms by which steel supports amplify the seismic response of the large 500 kV three-phase power transformer and provide a numerical evaluation of the effectiveness of a DFP base-isolation retrofit for this transformer.
Open AccessSeismic Response Amplification Mechanisms and Base-Isolation Retrofit Evaluation of a 500 kV Three-Phase Transformer with Steel Supports
The effects of steel supports on the dynamic characteristics and seismic demands of large three-phase power transformers remain insufficiently quantified. A three-dimensional finite-element model of a 500 kV three-phase transformer was developed to compare configurations without steel support (NS) and with steel support (WS). Modal characteristics and seismic bushing responses were evaluated under seven three-component ground motions. Frequency-response characteristics and global tank rotations were then analyzed, and a double friction pendulum (DFP) base-isolation retrofit was assessed. The lowest natural frequency of the WS model was 1.47 Hz, lower than the 1.84 Hz obtained for the NS model. For the representative X-direction response of high-voltage bushing A, the dominant low-frequency peak of the frequency-response function shifted from approximately 1.89 to 1.64 Hz, while its magnitude increased from approximately 8 to 19. The mean peak maximum principal tensile stress at the root of bushing A increased by 83.1%. The WS model also exhibited greater tank rocking and torsional responses, whose peaks were positively associated with the peak root stresses of bushings A and B. For representative high-voltage bushing B, the DFP retrofit achieved a mean isolation efficiency of approximately 60%. These results elucidate the mechanisms by which steel supports amplify the seismic response of the large 500 kV three-phase power transformer and provide a numerical evaluation of the effectiveness of a DFP base-isolation retrofit for this transformer.
- Open Access
- 18 June 2026
- Published by Elsevier in SSRN Electronic Journal
Three-Dimensional Seismic Response Mitigation of an Ultra-High-Voltage Converter Transformer Using a Hybrid Disc-Spring–Friction-Pendulum Bearing System
Converter transformers in ultra-high-voltage direct-current (UHVDC) transmission systems are highly vulnerable to combined horizontal and vertical seismic excitations, particularly at the inclined valve-side bushings, while conventional horizontal isolation systems exhibit limited capability in mitigating vertical seismic responses. To address this issue, this study proposes a disc-spring–friction-pendulum (DSFP) three-dimensional isolation system for a ±800 kV converter transformer. Experimental investigations were conducted to characterize the nonlinear stiffness and hysteretic energy-dissipation behavior of the disc-spring unit. Based on the experimental results, a finite element model of the DSFP bearing was developed and validated against the test data. Nonlinear time-history analyses were subsequently performed for non-isolated, horizontally isolated, and three-dimensionally isolated transformer systems subjected to seven three-component ground motions scaled to peak ground accelerations (PGAs) of 0.2 g, 0.4 g, and 0.6 g. At PGA = 0.6 g, the proposed DSFP system reduced the peak root stresses of the two valve-side bushings by approximately 65% compared with the non-isolated case and by 50% compared with the horizontally isolated case. Furthermore, frequency-domain analyses demonstrated that the DSFP bearing effectively suppresses vertical spectral peaks and high-frequency response components while preserving the horizontal isolation performance, thereby providing a promising approach for the seismic protection of ultra-high-voltage converter transformers.
- 18 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThree-Dimensional Seismic Response Mitigation of an Ultra-High-Voltage Converter Transformer Using a Hybrid Disc-Spring–Friction-Pendulum Bearing System
Converter transformers in ultra-high-voltage direct-current (UHVDC) transmission systems are highly vulnerable to combined horizontal and vertical seismic excitations, particularly at the inclined valve-side bushings, while conventional horizontal isolation systems exhibit limited capability in mitigating vertical seismic responses. To address this issue, this study proposes a disc-spring–friction-pendulum (DSFP) three-dimensional isolation system for a ±800 kV converter transformer. Experimental investigations were conducted to characterize the nonlinear stiffness and hysteretic energy-dissipation behavior of the disc-spring unit. Based on the experimental results, a finite element model of the DSFP bearing was developed and validated against the test data. Nonlinear time-history analyses were subsequently performed for non-isolated, horizontally isolated, and three-dimensionally isolated transformer systems subjected to seven three-component ground motions scaled to peak ground accelerations (PGAs) of 0.2 g, 0.4 g, and 0.6 g. At PGA = 0.6 g, the proposed DSFP system reduced the peak root stresses of the two valve-side bushings by approximately 65% compared with the non-isolated case and by 50% compared with the horizontally isolated case. Furthermore, frequency-domain analyses demonstrated that the DSFP bearing effectively suppresses vertical spectral peaks and high-frequency response components while preserving the horizontal isolation performance, thereby providing a promising approach for the seismic protection of ultra-high-voltage converter transformers.
- Open Access
- 18 June 2026
- Published by Elsevier in SSRN Electronic Journal
Three-Dimensional Seismic Response Mitigation of an Ultra-High-Voltage Converter Transformer Using a Hybrid Disc-Spring–Friction-Pendulum Bearing System
Converter transformers in ultra-high-voltage direct-current (UHVDC) transmission systems are highly vulnerable to combined horizontal and vertical seismic excitations, particularly at the inclined valve-side bushings, while conventional horizontal isolation systems exhibit limited capability in mitigating vertical seismic responses. To address this issue, this study proposes a disc-spring–friction-pendulum (DSFP) three-dimensional isolation system for a ±800 kV converter transformer. Experimental investigations were conducted to characterize the nonlinear stiffness and hysteretic energy-dissipation behavior of the disc-spring unit. Based on the experimental results, a finite element model of the DSFP bearing was developed and validated against the test data. Nonlinear time-history analyses were subsequently performed for non-isolated, horizontally isolated, and three-dimensionally isolated transformer systems subjected to seven three-component ground motions scaled to peak ground accelerations (PGAs) of 0.2 g, 0.4 g, and 0.6 g. At PGA = 0.6 g, the proposed DSFP system reduced the peak root stresses of the two valve-side bushings by approximately 65% compared with the non-isolated case and by 50% compared with the horizontally isolated case. Furthermore, frequency-domain analyses demonstrated that the DSFP bearing effectively suppresses vertical spectral peaks and high-frequency response components while preserving the horizontal isolation performance, thereby providing a promising approach for the seismic protection of ultra-high-voltage converter transformers.
- 18 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThree-Dimensional Seismic Response Mitigation of an Ultra-High-Voltage Converter Transformer Using a Hybrid Disc-Spring–Friction-Pendulum Bearing System
Converter transformers in ultra-high-voltage direct-current (UHVDC) transmission systems are highly vulnerable to combined horizontal and vertical seismic excitations, particularly at the inclined valve-side bushings, while conventional horizontal isolation systems exhibit limited capability in mitigating vertical seismic responses. To address this issue, this study proposes a disc-spring–friction-pendulum (DSFP) three-dimensional isolation system for a ±800 kV converter transformer. Experimental investigations were conducted to characterize the nonlinear stiffness and hysteretic energy-dissipation behavior of the disc-spring unit. Based on the experimental results, a finite element model of the DSFP bearing was developed and validated against the test data. Nonlinear time-history analyses were subsequently performed for non-isolated, horizontally isolated, and three-dimensionally isolated transformer systems subjected to seven three-component ground motions scaled to peak ground accelerations (PGAs) of 0.2 g, 0.4 g, and 0.6 g. At PGA = 0.6 g, the proposed DSFP system reduced the peak root stresses of the two valve-side bushings by approximately 65% compared with the non-isolated case and by 50% compared with the horizontally isolated case. Furthermore, frequency-domain analyses demonstrated that the DSFP bearing effectively suppresses vertical spectral peaks and high-frequency response components while preserving the horizontal isolation performance, thereby providing a promising approach for the seismic protection of ultra-high-voltage converter transformers.
- Open Access
- 27 December 2025
- Published by Elsevier in Journal of Infrastructure Intelligence and Resilience
- Vol. 5 (1)
Pareto-optimal seismic co-design of a novel integrated VibroHarvest system for long-period structures
- 27 December 2025
- Published by Elsevier in Journal of Infrastructure Intelligence and Resilience
- Vol. 5 (1)
Open AccessPareto-optimal seismic co-design of a novel integrated VibroHarvest system for long-period structures
- Open Access
- 11 October 2025
- Published by Academic Publishing Pte. Ltd. in Mechanical Engineering Advances
- Vol. 3 (4)
Optimal design of a novel TVMD-energy harvesting device for seismic control of long-period structures
Over the past ten years, energy harvesting (EH) from ambient energy has become essential for wireless applications, allowing low-powered electronics to operate. Due to the economic and ecological advantages of the EH technology, it is a promising idea to apply it to the seismic control of long-period structures while converting the earthquake input energy into electricity for structural health monitoring, earthquake observation, or other purposes. However, rare literature can be found on applying EH technology for the vibration control of long-period structures, especially in earthquake-prone areas. During extreme earthquakes, the tuned viscous mass damper (TVMD) exhibits an excellent control effect on long-period structures. To combine the advantages of EH and TVMD, a novel device, namely, the TVMD-EH damper, was proposed for the seismic control of long-period structures while harvesting the earthquake input energy simultaneously for electricity-needed purposes. A capacitor, a resistor, and piezoelectric material constructed an EH loop. Then, the EH loop was connected with the TVMD device to construct the TVMD-EH damper. In this study, the optimal design method for the TVMD-EH damper was proposed, and a feasibility study was conducted to investigate the performance of the device. The results demonstrate that the proposed TVMD-EH damper provides effective seismic response mitigation for the targeted structure while enabling simultaneous energy harvesting. In particular, the peak harvested electric power reaches 6.8 W under the El Centro record and 1.9 W under the Sakishima record suggesting practical potential for powering low-power independent sensors and related electronics and reducing battery dependence.
- 11 October 2025
- Published by Academic Publishing Pte. Ltd. in Mechanical Engineering Advances
- Vol. 3 (4)
Open AccessOptimal design of a novel TVMD-energy harvesting device for seismic control of long-period structures
Over the past ten years, energy harvesting (EH) from ambient energy has become essential for wireless applications, allowing low-powered electronics to operate. Due to the economic and ecological advantages of the EH technology, it is a promising idea to apply it to the seismic control of long-period structures while converting the earthquake input energy into electricity for structural health monitoring, earthquake observation, or other purposes. However, rare literature can be found on applying EH technology for the vibration control of long-period structures, especially in earthquake-prone areas. During extreme earthquakes, the tuned viscous mass damper (TVMD) exhibits an excellent control effect on long-period structures. To combine the advantages of EH and TVMD, a novel device, namely, the TVMD-EH damper, was proposed for the seismic control of long-period structures while harvesting the earthquake input energy simultaneously for electricity-needed purposes. A capacitor, a resistor, and piezoelectric material constructed an EH loop. Then, the EH loop was connected with the TVMD device to construct the TVMD-EH damper. In this study, the optimal design method for the TVMD-EH damper was proposed, and a feasibility study was conducted to investigate the performance of the device. The results demonstrate that the proposed TVMD-EH damper provides effective seismic response mitigation for the targeted structure while enabling simultaneous energy harvesting. In particular, the peak harvested electric power reaches 6.8 W under the El Centro record and 1.9 W under the Sakishima record suggesting practical potential for powering low-power independent sensors and related electronics and reducing battery dependence.
- Open Access
- 1 January 2025
- Published by Wiley in Structural Control and Health Monitoring
- Vol. 2025 (1)
Seismic Protection of Long‐Period Structures Using Modified Maxwell–Wiechert Damping Devices
In long‐period structures, rate‐independent linear damping (RILD) offers superior control of acceleration responses compared with conventional viscous damping. However, the noncausality of RILD limits its application in buildings. Further, practical implementation of methods to approximate RILD in specific situations remains challenging owing to the difficulty of mechanical realization. In this study, the inerter, Maxwell–Wiechert model, and negative stiffness were employed to construct novel RILD‐approximating devices: the negative‐stiffness inerter Maxwell–Wiechert (NSIMW) model and the NSI‐spring Maxwell–Wiechert (NSISMW) model. These devices were designed to replicate the storage and loss stiffness of RILD at the target frequencies. This study proposes causal devices for approximating RILD using inerters, negative stiffness, and Maxwell–Wiechert models. The initial design—the negative‐stiffness viscous‐inerter Maxwell–Wiechert (NSVIMW) model—was unrealizable owing to negative design parameters. To resolve this, the viscous damper was removed, resulting in a simplified NSI Maxwell–Wiechert (NSIMW) model. An enhanced version of the NSISMW model was further developed by adding a spring element. Both models were designed to match the storage and loss stiffness of RILD at target frequencies, and direct design methods were developed to determine their parameters. Real‐time hybrid simulations and analytical analyses were conducted to evaluate seismic control performance. The findings demonstrate that while NSIMW provides a causal approximation of RILD with moderate effectiveness, the NSISMW model achieves a more satisfactory seismic performance than the RILD, negative‐stiffness Maxwell–Wiechert model, and traditional tuned viscous mass dampers. These results clarify the relative merits of the two designs and suggest that the NSISMW model offers a promising direction for the practical implementation of RILD‐inspired damping systems.
- 1 January 2025
- Published by Wiley in Structural Control and Health Monitoring
- Vol. 2025 (1)
Open AccessSeismic Protection of Long‐Period Structures Using Modified Maxwell–Wiechert Damping Devices
In long‐period structures, rate‐independent linear damping (RILD) offers superior control of acceleration responses compared with conventional viscous damping. However, the noncausality of RILD limits its application in buildings. Further, practical implementation of methods to approximate RILD in specific situations remains challenging owing to the difficulty of mechanical realization. In this study, the inerter, Maxwell–Wiechert model, and negative stiffness were employed to construct novel RILD‐approximating devices: the negative‐stiffness inerter Maxwell–Wiechert (NSIMW) model and the NSI‐spring Maxwell–Wiechert (NSISMW) model. These devices were designed to replicate the storage and loss stiffness of RILD at the target frequencies. This study proposes causal devices for approximating RILD using inerters, negative stiffness, and Maxwell–Wiechert models. The initial design—the negative‐stiffness viscous‐inerter Maxwell–Wiechert (NSVIMW) model—was unrealizable owing to negative design parameters. To resolve this, the viscous damper was removed, resulting in a simplified NSI Maxwell–Wiechert (NSIMW) model. An enhanced version of the NSISMW model was further developed by adding a spring element. Both models were designed to match the storage and loss stiffness of RILD at target frequencies, and direct design methods were developed to determine their parameters. Real‐time hybrid simulations and analytical analyses were conducted to evaluate seismic control performance. The findings demonstrate that while NSIMW provides a causal approximation of RILD with moderate effectiveness, the NSISMW model achieves a more satisfactory seismic performance than the RILD, negative‐stiffness Maxwell–Wiechert model, and traditional tuned viscous mass dampers. These results clarify the relative merits of the two designs and suggest that the NSISMW model offers a promising direction for the practical implementation of RILD‐inspired damping systems.
- Open Access
- 26 February 2024
- Published by Elsevier in Computers & Structures
- Vol. 297
Modal decomposition of multi-degree-of-freedom structure with non-proportionally distributed rate-independent linear damping
- 26 February 2024
- Published by Elsevier in Computers & Structures
- Vol. 297
Open AccessModal decomposition of multi-degree-of-freedom structure with non-proportionally distributed rate-independent linear damping
- Open Access
- 9 January 2024
- Published by Wiley in Structural Control and Health Monitoring
- Vol. 2024 (1)
Feasibility Study of a Novel Modal Decomposition Method for Low‐Frequency Structure with Nonproportionally Distributed Rate‐Independent Linear Damping
Compared with conventional linear viscous damping (LVD), rate‐independent linear damping (RILD) mitigates floor response acceleration in low‐frequency structures more effectively without compromising the control performance of displacement responses during long‐period or low‐frequency earthquakes. Although theoretical and experimental attempts have been made to overcome the noncausality of RILD devices and realize RILD using passive or semiactive devices, only a few studies have highlighted the impulse‐response precursor and modal analysis method of multistory structures incorporated into RILD devices. This study investigated the impulse‐response precursor of a noncausal RILD system and proposed a novel modal decomposition method for the structures equipped with nonproportionally distributed RILD devices. Additionally, real‐time hybrid simulation was conducted to validate the effectiveness of the proposed modal analysis method and the feasibility of realizing ideal RILD using mechanical devices. This study is the first to demonstrate the differences between RILD and LVD devices in terms of controlling the modal responses of low‐frequency structures and how RILD can lower the floor response acceleration more effectively compared to LVD.
- 9 January 2024
- Published by Wiley in Structural Control and Health Monitoring
- Vol. 2024 (1)
Open AccessFeasibility Study of a Novel Modal Decomposition Method for Low‐Frequency Structure with Nonproportionally Distributed Rate‐Independent Linear Damping
Compared with conventional linear viscous damping (LVD), rate‐independent linear damping (RILD) mitigates floor response acceleration in low‐frequency structures more effectively without compromising the control performance of displacement responses during long‐period or low‐frequency earthquakes. Although theoretical and experimental attempts have been made to overcome the noncausality of RILD devices and realize RILD using passive or semiactive devices, only a few studies have highlighted the impulse‐response precursor and modal analysis method of multistory structures incorporated into RILD devices. This study investigated the impulse‐response precursor of a noncausal RILD system and proposed a novel modal decomposition method for the structures equipped with nonproportionally distributed RILD devices. Additionally, real‐time hybrid simulation was conducted to validate the effectiveness of the proposed modal analysis method and the feasibility of realizing ideal RILD using mechanical devices. This study is the first to demonstrate the differences between RILD and LVD devices in terms of controlling the modal responses of low‐frequency structures and how RILD can lower the floor response acceleration more effectively compared to LVD.
- 9 September 2023
- Published by Elsevier in Journal of Building Engineering
- Vol. 78
Seismic control of base-isolated structures using rate-independent damping devices
- 9 September 2023
- Published by Elsevier in Journal of Building Engineering
- Vol. 78
Seismic control of base-isolated structures using rate-independent damping devices