YDYukun DU

Yukun DU

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yukun DU has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Machine Learning-Based Predictions for the Peak Impact Forces of Reinforced Concrete Beams from a Drop Weight

    by Tianli Chen, Yukun Du, Xiaoyan Zhang, Xiaozhen Li, Li Zhang

    Accurate prediction of the peak impact force of reinforced concrete (RC) structures subjected to impact loads is critical for its impact-resistant design and structural performance assessment. Traditional approaches, such as experimental testing and refined finite element (FE) analysis, are generally time-consuming and resource-intensive. To address these limitations, this study develops an application-oriented machine learning (ML) framework for predicting the peak impact force of RC beams during the impact process. A comprehensive dataset comprising 144 samples is constructed from publicly available drop-hammer impact tests on rectangular simply supported RC beams based on the predefined selection criteria. Five ML models, i.e., Support Vector Regression (SVR), Random Forest Regression (RFR), Gaussian Process Regression (GPR), Extreme Gradient Boosting (XGBoost), and Artificial Neural Networks (ANN), are employed to predict peak impact force, and the corresponding model performances are evaluated by comparing with the experimental results. The SHapley Additive exPlanations (SHAP) algorithm and Local Interpretable Model-Agnostic Explanations (LIME) are utilized to assess the relative importance of input features. Based on feature importance, Monte Carlo simulations are further conducted to examine the influence of varying numbers of input features on prediction performance, and a feature reduction strategy is proposed and evaluated. The reliability and effectiveness of the proposed feature reduction strategy are evaluated using five independent experimental cases that are completely excluded from model development, and eleven numerical simulation cases are employed for further supplementary assessment. It is found that: (i) XGBoost achieves the best predictive performance for peak impact force, with a coefficient of determination (R2) of 0.976 on the testing set; (ii) impact velocity and yield strength of longitudinal reinforcement are the most influential features for predicting peak impact force; (iii) the feature reduction strategy with seven input features provides an optimal balance between the model complexity and predictive accuracy for rapid structural design and performance assessment.

  • Open Access

    Seismic Response Amplification Mechanisms and Base-Isolation Retrofit Evaluation of a 500 kV Three-Phase Transformer with Steel Supports

    by Yukun Du, Li Zhang, Jing Xie, Xiaoxuan Li, Wei Liu

    The effects of steel supports on the dynamic characteristics and seismic demands of large three-phase power transformers remain insufficiently quantified. A three-dimensional finite-element model of a 500 kV three-phase transformer was developed to compare configurations without steel support (NS) and with steel support (WS). Modal characteristics and seismic bushing responses were evaluated under seven three-component ground motions. Frequency-response characteristics and global tank rotations were then analyzed, and a double friction pendulum (DFP) base-isolation retrofit was assessed. The lowest natural frequency of the WS model was 1.47 Hz, lower than the 1.84 Hz obtained for the NS model. For the representative X-direction response of high-voltage bushing A, the dominant low-frequency peak of the frequency-response function shifted from approximately 1.89 to 1.64 Hz, while its magnitude increased from approximately 8 to 19. The mean peak maximum principal tensile stress at the root of bushing A increased by 83.1%. The WS model also exhibited greater tank rocking and torsional responses, whose peaks were positively associated with the peak root stresses of bushings A and B. For representative high-voltage bushing B, the DFP retrofit achieved a mean isolation efficiency of approximately 60%. These results elucidate the mechanisms by which steel supports amplify the seismic response of the large 500 kV three-phase power transformer and provide a numerical evaluation of the effectiveness of a DFP base-isolation retrofit for this transformer.

  • Open Access

    Three-Dimensional Seismic Response Mitigation of an Ultra-High-Voltage Converter Transformer Using a Hybrid Disc-Spring–Friction-Pendulum Bearing System

    by Yukun DU, Xiaoxuan Li, Jing Xie, Qiang Xie, Wei Liu

    Converter transformers in ultra-high-voltage direct-current (UHVDC) transmission systems are highly vulnerable to combined horizontal and vertical seismic excitations, particularly at the inclined valve-side bushings, while conventional horizontal isolation systems exhibit limited capability in mitigating vertical seismic responses. To address this issue, this study proposes a disc-spring–friction-pendulum (DSFP) three-dimensional isolation system for a ±800 kV converter transformer. Experimental investigations were conducted to characterize the nonlinear stiffness and hysteretic energy-dissipation behavior of the disc-spring unit. Based on the experimental results, a finite element model of the DSFP bearing was developed and validated against the test data. Nonlinear time-history analyses were subsequently performed for non-isolated, horizontally isolated, and three-dimensionally isolated transformer systems subjected to seven three-component ground motions scaled to peak ground accelerations (PGAs) of 0.2 g, 0.4 g, and 0.6 g. At PGA = 0.6 g, the proposed DSFP system reduced the peak root stresses of the two valve-side bushings by approximately 65% compared with the non-isolated case and by 50% compared with the horizontally isolated case. Furthermore, frequency-domain analyses demonstrated that the DSFP bearing effectively suppresses vertical spectral peaks and high-frequency response components while preserving the horizontal isolation performance, thereby providing a promising approach for the seismic protection of ultra-high-voltage converter transformers.

  • Open Access

    Three-Dimensional Seismic Response Mitigation of an Ultra-High-Voltage Converter Transformer Using a Hybrid Disc-Spring–Friction-Pendulum Bearing System

    by Yukun DU, Xiaoxuan Li, Jing Xie, Qiang Xie, Wei Liu

    Converter transformers in ultra-high-voltage direct-current (UHVDC) transmission systems are highly vulnerable to combined horizontal and vertical seismic excitations, particularly at the inclined valve-side bushings, while conventional horizontal isolation systems exhibit limited capability in mitigating vertical seismic responses. To address this issue, this study proposes a disc-spring–friction-pendulum (DSFP) three-dimensional isolation system for a ±800 kV converter transformer. Experimental investigations were conducted to characterize the nonlinear stiffness and hysteretic energy-dissipation behavior of the disc-spring unit. Based on the experimental results, a finite element model of the DSFP bearing was developed and validated against the test data. Nonlinear time-history analyses were subsequently performed for non-isolated, horizontally isolated, and three-dimensionally isolated transformer systems subjected to seven three-component ground motions scaled to peak ground accelerations (PGAs) of 0.2 g, 0.4 g, and 0.6 g. At PGA = 0.6 g, the proposed DSFP system reduced the peak root stresses of the two valve-side bushings by approximately 65% compared with the non-isolated case and by 50% compared with the horizontally isolated case. Furthermore, frequency-domain analyses demonstrated that the DSFP bearing effectively suppresses vertical spectral peaks and high-frequency response components while preserving the horizontal isolation performance, thereby providing a promising approach for the seismic protection of ultra-high-voltage converter transformers.