Abdallah A. Aboelnaga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abdallah A. Aboelnaga has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Maher Abdelkhalek Azzouz
University of Windsor
3 shared publications - Ahmed S. A. Awad
Department of Electrical and Computer Engineering, Sultan Qaboos University, Muscat, Oman
1 shared publication - Hatem Faiz Sindi
King Abdulaziz University
1 shared publication
Latest Publications
- 25 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 15 (2) , 1380-1395
Dual Current Control of Renewable Energy Sources for Recent Grid Code Compliance and Reliability Enhancement
Inverter-interfaced renewable energy sources (IIRESs) are controlled to follow low-voltage ride-through requirements during different fault conditions to support grid voltages and enhance stability. However, these requirements could result in improper operation of conventional protection functions, e.g., phase selection, that are designed based on the fault current characteristics of conventional power systems. In this paper, a dual-current controller (DCC) is designed for IIRESs to allow precise operation of the conventional phase selection method (PSM) while following the positive- and negative-sequence reactive current generation (RCG) requirements imposed by recent grid codes (GCs). First, the negative-sequence current reference is designed to comply with GC requirements and inject the minimum value of negative-sequence-active current that secures a correct operation of phase selection. Subsequently, the positive-sequence-reactive current is designed to comply with RCG requirements and allow injecting the maximum combination of the positive-and negative-sequence currents without hindering the proper operation of PSM or RCG requirements. Comprehensive time-domain simulations verify the effectiveness of the proposed DCC in meeting both PSM and recent RCG requirements during different fault types, resistances, and locations.
- 25 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 15 (2) , 1380-1395
Dual Current Control of Renewable Energy Sources for Recent Grid Code Compliance and Reliability Enhancement
Inverter-interfaced renewable energy sources (IIRESs) are controlled to follow low-voltage ride-through requirements during different fault conditions to support grid voltages and enhance stability. However, these requirements could result in improper operation of conventional protection functions, e.g., phase selection, that are designed based on the fault current characteristics of conventional power systems. In this paper, a dual-current controller (DCC) is designed for IIRESs to allow precise operation of the conventional phase selection method (PSM) while following the positive- and negative-sequence reactive current generation (RCG) requirements imposed by recent grid codes (GCs). First, the negative-sequence current reference is designed to comply with GC requirements and inject the minimum value of negative-sequence-active current that secures a correct operation of phase selection. Subsequently, the positive-sequence-reactive current is designed to comply with RCG requirements and allow injecting the maximum combination of the positive-and negative-sequence currents without hindering the proper operation of PSM or RCG requirements. Comprehensive time-domain simulations verify the effectiveness of the proposed DCC in meeting both PSM and recent RCG requirements during different fault types, resistances, and locations.
- 18 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 13 (4) , 2275-2290
Fault Ride Through of Inverter-Interfaced Renewable Energy Sources for Enhanced Resiliency and Grid Code Compliance
Inverter-interfaced renewable energy sources (IIRESs) are typically controlled during fault conditions to meet fault ride-through (FRT) requirements, e.g., reactive current generation (RCG) requirements specified by grid codes (GCs). However, fault currents generated by inverters are different from the traditional sources, i.e., synchronous generators. Consequently, phase selection methods (PSMs) used by protection relays could suffer from erroneous fault type classification. This paper develops a dual current controller (DCC) that regulates the inverter's negative- and positive-sequence currents to simultaneously meet phase selection and RCG requirements. First, the negative-sequence-current angle is obtained based on the angles of both zero- and positive-sequence currents to enable a correct operation for phase selection. Then, the positive-sequence current angle is adjusted to reach a trade-off between RCG requirements and phase selection achieved by the negative-sequence current. Lastly, the reference currents of the IIRES are generated in the stationary frame without violating the inverter's current limits. The proposed DCC supports the grid voltage by meeting the RCG requirements and enhancing the grid reliability and resilience by enabling correct phase selection. Comprehensive time-domain and real-time simulation verify the precise operation of the proposed DCC under various fault conditions and GCs.
- 18 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 13 (4) , 2275-2290
Fault Ride Through of Inverter-Interfaced Renewable Energy Sources for Enhanced Resiliency and Grid Code Compliance
Inverter-interfaced renewable energy sources (IIRESs) are typically controlled during fault conditions to meet fault ride-through (FRT) requirements, e.g., reactive current generation (RCG) requirements specified by grid codes (GCs). However, fault currents generated by inverters are different from the traditional sources, i.e., synchronous generators. Consequently, phase selection methods (PSMs) used by protection relays could suffer from erroneous fault type classification. This paper develops a dual current controller (DCC) that regulates the inverter's negative- and positive-sequence currents to simultaneously meet phase selection and RCG requirements. First, the negative-sequence-current angle is obtained based on the angles of both zero- and positive-sequence currents to enable a correct operation for phase selection. Then, the positive-sequence current angle is adjusted to reach a trade-off between RCG requirements and phase selection achieved by the negative-sequence current. Lastly, the reference currents of the IIRES are generated in the stationary frame without violating the inverter's current limits. The proposed DCC supports the grid voltage by meeting the RCG requirements and enhancing the grid reliability and resilience by enabling correct phase selection. Comprehensive time-domain and real-time simulation verify the precise operation of the proposed DCC under various fault conditions and GCs.
- 15 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 13 (1) , 417-428
Adaptive Current-Angle-Based Phase Selection for Microgrids With Inverter-Interfaced Renewable Energy Sources
Renewable energy sources (RESs) possess different fault signatures as compared to the traditional synchronous generators, thus introducing new challenges for microgrid protection. Among these challenges is phase selection, which is a prerequisite for selective phase tripping (SPT). This paper analyzes the root causes behind the failure of current-angle-based phase selection methods (PSMs) used by commercial relays in microgrids with inverter-interfaced RESs (IIRESs). Besides, the operation of the recently-developed voltage-angle-based PSM is investigated to unveil its points of strength and weakness. Then, adaptive zoning for the current-angle-based PSM is proposed to cope with the unconventional IIRES fault current signatures and enable precise SPT. As a result, microgrid reliability and resiliency during faults are enhanced. The proposed PSM depends on local measurements to update the PSM zones online by estimating the angles between the sequence impedances behind a relay. Comprehensive time-domain simulations verify the effectiveness of the proposed PSM at various fault resistances, fault locations, and microgrid topologies.
- 15 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 13 (1) , 417-428
Adaptive Current-Angle-Based Phase Selection for Microgrids With Inverter-Interfaced Renewable Energy Sources
Renewable energy sources (RESs) possess different fault signatures as compared to the traditional synchronous generators, thus introducing new challenges for microgrid protection. Among these challenges is phase selection, which is a prerequisite for selective phase tripping (SPT). This paper analyzes the root causes behind the failure of current-angle-based phase selection methods (PSMs) used by commercial relays in microgrids with inverter-interfaced RESs (IIRESs). Besides, the operation of the recently-developed voltage-angle-based PSM is investigated to unveil its points of strength and weakness. Then, adaptive zoning for the current-angle-based PSM is proposed to cope with the unconventional IIRES fault current signatures and enable precise SPT. As a result, microgrid reliability and resiliency during faults are enhanced. The proposed PSM depends on local measurements to update the PSM zones online by estimating the angles between the sequence impedances behind a relay. Comprehensive time-domain simulations verify the effectiveness of the proposed PSM at various fault resistances, fault locations, and microgrid topologies.