MTMasashi Takakura

Masashi Takakura

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Masashi Takakura has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Intraoperative hypotension affects postoperative acute kidney injury depending on the invasiveness of abdominal surgery: A retrospective cohort study

    by Tasuku Fujii, Masashi Takakura, Tomoya Taniguchi, Takahiro Tamura, Kimitoshi Nishiwaki

    Intraoperative hypotension (IOH) or highly invasive surgery adversely affects postoperative clinical outcomes. It is, however, unclear whether IOH affects postoperative acute kidney injury (AKI) depending on the invasiveness of abdominal surgery. We speculated that IOH in highly invasive abdominal surgery is a significant risk factor for postoperative AKI. We retrospectively reviewed the data of 448 patients who underwent abdominal surgery. Patients were divided into 3 groups: highly (such as pancreaticoduodenectomy and hepatectomy), moderately (open abdominal surgery), and minimally (laparoscopic surgery) invasive surgeries. The association between the time-weighted average (TWA) of mean arterial pressure (MAP) values (≤60 and ≤ 55 mm Hg) and AKI occurrences in each group was assessed. Postoperative AKI occurred after highly, moderately, and minimally invasive surgeries in 33 of 222 (14.9%), 14 of 110 (12.7%), and 12 of 116 (10.3%) cases, respectively (P = .526). The median [interquartile range] of TWA-MAP ≤ 60 mm Hg, as an IOH parameter, was 0.94 [0.33–2.08] mm Hg in highly, 0.54 [0.16–1.46] mm Hg in moderately, and 0.14 [0.03–0.57] mm Hg in minimally invasive surgeries (P < 0001). In addition, there was a significant association between TWA-MAP and AKI in highly invasive surgery, unlike in moderately and minimally invasive surgery, with adjusted odds ratios (95% confidence interval) for TWA-MAP ≤ 60 and ≤ 55 mm Hg associated with AKI of 1.23 [1.00–1.52] (P = .049) and 1.55 [1.02–2.36] (P = .041), respectively. Intraoperative MAP ≤ 60 mm Hg in highly invasive abdominal surgery is associated with postoperative AKI, compared to moderately and minimally invasive surgeries. Additionally, low MAP thresholds in highly invasive surgery increase postoperative AKI risk.


  • Interference of a ventricular assist device with magnetic navigation during insertion of Sherlock 3CG™, a bedside peripherally inserted central catheter

    by Masashi Takakura, Tasuku Fujii, Shogo Suzuki, Kimitoshi Nishiwaki

    Recently, the Sherlock 3CG™ Tip Confirmation System, including a magnetic tracking system and an intracavitary electrocardiography guidance system, has been introduced for bedside peripherally inserted central catheter (PICC) insertion. Magnetic field sources interfere with the magnetic tracking system. Electromagnetic interference of the ventricular assist device (VAD) has already been reported with various devices but not on Sherlock 3CG™. We assessed the availability of the magnetic tracking system in patients with and without a VAD during Sherlock 3CG™ insertion and evaluated the rate of optimal PICC tip position. We retrospectively reviewed 99 patients who had undergone PICC insertion using Sherlock 3CG™ on the bedside at our institutional intensive care unit from February 2018 to December 2020. Patients were divided into groups with and without a VAD. The availability of magnetic navigation and the success rate of optimal catheter tip position in each group were assessed. Among 87 cases analyzed, there were 12 and 75 cases with a VAD and without a VAD, respectively. The availability of magnetic navigation during Sherlock 3CG™ insertion was significantly lower in the group with a VAD [4/12 (33%) with VAD vs. 72/75 (96%) without VAD, P < 0.001]. In addition, the rate of optimal PICC tip position was also significantly lower in the group with a VAD [6/12 (50%) vs. 63/75 (84%), P = 0.015] The VAD significantly led to magnetic tracking system failure due to its electromagnetic interference during Sherlock 3CG™ insertion and significantly reduced the success rate of PICC insertions in the optimal position.