ZXZhiyong Xu

Zhiyong Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zhiyong Xu has a total of 114 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Study on the effects of estimated dose of radiation to immune cells and CBC parameters on the prognosis of patients with locally advanced non-small cell lung cancer undergoing radiotherapy

    by Aihui Feng, Wuyan Xia, Yan Shao, Hao Wang, Hua Chen, Hengle Gu, Yanhua Duan, Ying Huang, Zhenjiong Shen, Jiaou Chen, et al.

    Background: Locally advanced non-small-cell lung cancer (LA-NSCLC) is a subtype of lung cancer with substantial heterogeneity in clinical prognosis. Immune injury induced by radiotherapy exposure is a critical factor affecting treatment response and long-term outcomes. This study enrolled patients with LA-NSCLC to investigate the prognostic value of complete blood count (CBC) parameters combined with the estimated dose of radiation to immune cells (EDRIC), aiming to facilitate precision prognostic stratification and tailored treatment strategies in clinical practice. Materials and methods: This study included 329 patients with LA-NSCLC who received radiotherapy (RT) at our institution. Serial CBC measurements were obtained pre-RT, weekly during RT, and 1-month post-RT. EDRIC was calculated based on the model developed by Jin et al. and improved by Ladbury et al. We subsequently evaluated the associations of EDRIC and CBC parameters with overall survival (OS), local recurrence-free survival (LRFS), distant metastasis-free survival (DMFS), and progression-free survival (PFS). Results: Univariate and multivariate analyses demonstrated that EDRIC, together with week 3 platelet-to-lymphocyte ratio (PLR), was significantly associated with OS, LRFS, DMFS, and PFS ( P < 0.05). In multivariate models, neither MHD, MLD, nor MBD was significantly associated with survival outcomes, regardless of the inclusion of EDRIC; however, EDRIC demonstrated a significant correlation. For OS discrimination, Harrell’s C-index reached 0.622 for the EDRIC-alone model, 0.734 for the model integrating clinical covariates and CBC markers, and 0.740 for the combined model incorporating clinical features, serial CBC indices and EDRIC. Conclusions: EDRIC is an independent prognostic biomarker for OS, LRFS, PFS and DMFS in LA-NSCLC patients undergoing definitive thoracic (chemo)radiotherapy. Week 3 PLR also independently predicts all four survival endpoints. Compared with the EDRIC-only model, the integrated model incorporating pretreatment EDRIC, clinical variables, and on-treatment inflammatory markers (NLR and PLR) yields more accurate and comprehensive prognostic stratification for patients with LA-NSCLC.

  • Open Access

    Comparison of dosimetric parameters and delivery accuracy between conformal radiotherapy-intensity modulated radiotherapy-combined and intensity-modulated radiotherapy planning for central lung cancer patients receiving stereotactic body radiotherapy

    by Yan Shao, Jindong Guo, Yanhua Duan, Ying Huang, Aihui Feng, Hua Chen, Hao Wang, Hengle Gu, Zhenjiong Shen, Zhiyong Xu

    Background: With the development of technology, stereotactic body radiotherapy (SBRT) has been increasingly applied in the treatment of patients with central lung cancer. Three-dimensional conformal radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT) are common SBRT techniques for lung cancer. Although 3DCRT plans have low complexity, the quality of such plans is highly dependent on the experience of the planner. IMRT plans can provide better organ-at-risk (OAR) sparing, but they are associated with a high degree of modulation. Therefore, an SBRT planning strategy that combines the advantages of 3DCRT and IMRT has been developed. The purpose of this study was to investigate the differences in dosimetric parameters and delivery accuracy between CRT-IMRT-combined (Co-CRIM) and IMRT plans for central lung cancer patients treated with SBRT. Methods: Twenty patients were retrospectively included in this study. Four plans were designed for each patient. Co-CRIM-E and IMRT-E plans were designed based on Co-CRIM and IMRT, and delivered with Varian Edge. Co-CRIM-T and IMRT-T plans were designed based on Co-CRIM and IMRT, and delivered with Varian TrueBeam. Dosimetric parameters were compared between Co-CRIM-E and IMRT-E plans, as well as between Co-CRIM-T and IMRT-T plans. Monitor unit (MU), modulation factor (MF) and gamma (γ) passing rate were calculated for each plan. Paired-samples t-test was used to check the differences between datasets and PResults: Conformity index (CI), ratio of 50% prescription isodose volume to the planning target volume (PTV) volume (R50) and maximum dose (in % of dose prescribed) at 2 cm from PTV in any direction (D2cm) were significantly higher in Co-CRIM-E plans than those in IMRT-E plans. The CI, D2cm in Co-CRIM-T plans were also significantly higher than those in IMRT-T plans. Mean lung dose (MLD), percentage of the total lung volume receiving more than 10 Gy (V10), 12.5 Gy (V12.5), 13.5 Gy (V13.5) and 20 Gy (V20) were significantly higher in Co-CRIM-E plans than those in IMRT-E plans. MLD, V10, V12.5, V13.5 and V20 of total lung in Co-CRIM-T plans were also significantly higher than those in IMRT-T plans. MU and MF were significantly lower in Co-CRIM-E and Co-CRIM-T plans than those in IMRT-E and IMRT-T plans and γ passing rate was significantly higher than that in IMRT-E and IMRT-T plan. Conclusions: For central lung cancer patients treated with SBRT, the Co-CRIM approach was able to achieve plans that met clinical constraints. Compared with IMRT, Co-CRIM significantly reduced plan complexity and improved delivery accuracy with slightly reduced target conformability.

  • Open Access

    Explainable machine learning for patient‐specific quality assurance in intensity‐modulated radiotherapy based on anatomical structures

    by Xuerou Zhang, Ying Huang, Jie Wang, Xingtong Zhang, Hua Chen, Yehui Luo, Jianhao Xie, Zhiyong Xu, Yunhua Xu

    Background: Patient‐specific quality assurance (PSQA) plays a pivotal role in intensity‐modulated radiotherapy (IMRT) to ensure accurate dose delivery. However, conventional measurement‐based PSQA approaches are labor‐intensive and provide limited insight into the underlying factors contributing to variations in gamma passing rates (GPRs). Anatomical characteristics of the planning target volume (PTV) and organs at risk (OARs) may contain predictive information relevant to GPR performance, yet their potential has not been fully explored within interpretable machine learning frameworks. Purpose: This study aimed to develop an interpretable machine learning (ML) framework for predicting GPRs in IMRT based on anatomical features extracted from the PTV and OARs. Methods: A retrospective cohort of 243 clinical chest IMRT plans was analyzed. Radiomic and dosimetric features were extracted for each anatomical structure. Two ML regression models—Random Forest (RF) and eXtreme Gradient Boosting (XGBoost)—were developed to predict GPRs for the PTV and OARs under four gamma criteria (3%/3 mm, 3%/2 mm, 2%/3 mm, and 2%/2 mm). The GPR obtained by comparing the dose distribution reconstructed using the independent Monte Carlo (MC) dose calculation software ArcherQA (Wisdom Technology Company Limited, Hefei, China)—based on linear accelerator delivery log files—with the original planned dose distribution was used as the reference standard, and calculated using global gamma analysis with a 10% dose threshold. Model performance was evaluated using the mean absolute error (MAE), root mean square error (RMSE), and Spearman's rank correlation coefficient. Shapley Additive Explanations (SHAP) were applied to interpret feature contributions in the best‐performing model. Results: Both models demonstrated robust predictive performance across different anatomical structures and gamma criteria. As the gamma criteria became less stringent, prediction errors decreased accordingly. Prediction accuracy was relatively high for OARs; for example, under the 3%/3 mm criterion, the test‐set MAE was 0.06% ± 0.01% for the heart and 0.26% ± 0.04% for the whole lung. In contrast, the prediction error was relatively larger for the PTV, with a test‐set MAE of 1.98% ± 0.31% under the same criterion. SHAP analysis revealed that texture‐related radiomic features contributed most substantially to model predictions. Moreover, feature importance patterns varied according to organ type and gamma‐criterion stringency. Conclusions: Multi‐omics descriptors derived from anatomical structures can reliably predict GPRs in IMRT. The proposed interpretable ML framework not only achieves accurate prediction but also enhances mechanistic understanding through SHAP‐based explanations. These findings provide valuable insights into dose verification variability and offer a practical, transparent tool for IMRT patient‐specific quality assurance.

  • Open Access

    Explicit modeling of beam geometry improves three-dimensional dose prediction for esophageal cancer radiotherapy under heterogeneous beam configurations

    by Yanhua Duan, Hua Chen, Hao Wang, Hongbin Cao, Hengle Gu, Yan Shao, Aihui Feng, Ying Huang, Zhenjiong Shen, Qing Kong, et al.

    Deep learning-based 3D dose prediction boosts radiotherapy planning efficiency and consistency, yet most models rely solely on anatomical data and assume h

  • Open Access

    Cardiac substructure-guided radiotherapy planning for esophageal cancer: a novel strategy for cardiotoxicity reduction

    by Yan Shao, Zhangru Yang, Aihui Feng, Hengle Gu, Hao Wang, Hua Chen, Yanhua Duan, Ying Huang, Zhenjiong Shen, Zhiyong Xu

    A novel method was proposed to protect the sensitive cardiac substructures in esophageal cancer patients and reduce the risk of cardiotoxicity. A retrospec


  • Open Access

    Functional lung avoidance stereotactic body radiation therapy for central lung cancer patients

    by Aihui Feng, Yanhua Duan, Yan Shao, Hao Wang, Hua Chen, Hengle Gu, Ying Huang, Zhenjiong Shen, Xufei Wang, Zhiyong Xu

    Background: To improve patients’ quality of life, it is necessary to preserve the high-functioning regions of the lung. This study aimed to propose a planning strategy that prioritizes sparing ventilation function for stereotactic body radiation therapy (SBRT) in patients with central lung cancer. Methods: Twenty patients with central lung cancer were retrospectively enrolled. Ventilation maps were obtained from 4-dimensional computed tomography by deformable image registration and quantitative analysis. The top 60% and 30–60% of the total lung were defined as high- and medium-ventilation regions, respectively. Clinical plans and functional lung avoidance (FLA) plans were designed for each patient, and FLA plans were optimized to spare high-ventilation (H-V) regions. Dosimetric parameters were compared in terms of tumor coverage, plan heterogeneity, and dose of organs-at-risk (OARs). A patient-specific dose-function response model of Owen was applied to characterize personalized functional damage. Results: FLA plans led to significant reductions in the mean dose of H-V lung than in clinical plans (361.33 vs. 398.51 cGy, P vs. 4.58, P vs. 0.86, P vs. 3.42%, PConclusions: FLA plans can preserve the post-radiotherapy lung function, limit the pulmonary toxicity, and further improve life quality for SBRT patients with central lung cancer.


  • Open Access

    Prediction of three-dimensional dose distribution for patient-specific quality assurance based on log files using WingsNet

    by Ying Huang, Yifei Pi, Ruxin Cai, Kui Ma, Hao Wang, Hua Chen, Hengle Gu, Yan Shao, Aihui Feng, Yanhua Duan, et al.

    Background: This study aims to construct and train the WingsNet model, which leverages the parameters recorded in log files to rapidly and accurately predict the patient-specific three-dimensional (3D) dose distribution for IMRT quality assurance (QA). Methods: We conducted a retrospective analysis of data from 286 lung cancer patients treated with a prescription of 60 Gy in 30 fractions, with 242 cases used for model training and 44 for testing. Log files containing information such as multi-leaf collimator (MLC) positions, monitor units (MU), and gantry angles were collected from Varian treatment accelerators. Pylinac software was employed to extract mechanical parameters from the log files, generating 2D fluence maps, which were then converted into 3D volumes using a ray-tracing algorithm. CT images, RT structures, and 3D volumes were resampled to a uniform dimension of 128*128*128 to serve as input for the WingsNet model, with the 3D dose distribution calculated by the treatment planning system (TPS) serving as output. The model training utilized L1 loss and mean squared error (MSE) as evaluation metrics. Results: The results of this study demonstrate that the WingsNet model can effectively predict the 3D dose distribution of IMRT plans based on the parameters recorded in the log files. Evaluation through metrics such as mean absolute error (MAE), root mean square error (RMSE), and dose-volume histogram (DVH) indices reveals that the model performs well in most areas, with some errors observed in the planning target volume (PTV) region and at high dose levels, yet it retains potential for clinical use. Visually, the isodose line distributions are consistent. The Dice coefficients between the predicted and reference dose distributions at varying isodose line levels indicate a decreasing trend as the dose level increases. Conclusions: The WingsNet model developed in this study successfully predicts the patient-specific 3D dose distribution for QA by parsing the parameters recorded in log files. This model shows promise for use in 3D dose distribution verification for IMRT, providing an efficient and reliable tool for the verification of 3D dose distributions in patient-specific QA.

  • Open Access

    Dosimetric Performance of Orthogonal Dual-Layer Multi-Leaf Collimator System on Locally Advanced Lung Cancer: Cardiac Substructures Sparing Plans

    by AiHui Feng, YanHua Duan, ZhangRu Yang, Hao Wang, Hua Chen, HengLe Gu, Ying Huang, ZhenJiong Shen, XuFei Wang, ZhiYong Xu

  • Open Access

    Dosimetric comparison of two linear accelerators for lung cancer SBRT using IMRT dose delivery technique: VenusX vs. Edge

    by Yanhua Duan, Shanshan Zhong, Aihui Feng, Qing Kong, Zhiyong Xu

    The VenusX and Edge accelerators are two commercially available systems used for lung stereotactic body radiation therapy (SBRT) with Intensity-Modulated Radiation Therapy (IMRT) techniques. A retrospective analysis was conducted on 40 lung cancer patients treated with the Edge accelerator. Treatment plans using both the Edge (PlanEdge) and VenusX (PlanVX) accelerators were generated and evaluated using various dosimetric metrics, employing statistical analyses to identify significant differences. For planned target volume (PTV), Plan VX outperformed PlanEdge across the entire cohort, achieving a higher D2 dose (76.84 vs 75.56 Gy, p = 0.005), and showing significant improvements in conformity index (0.84 vs 0.80), homogeneity index (0.50 vs 0.47), and gradient index (5.12 vs 5.62), all with p < 0.001. Plan VX also recorded a lower D2 cm (27.27 vs 27.87 Gy, p = 0.004). Subgroup analyses revealed significant enhancements in conformity index (CI), homogeneity index (HI), and gradient index (GI) for both single and multi-target lesion patients, with multi-target also seeing a notably lower D2 cm. regarding organs at risk (OARs), Plan VX significantly reduced lung mean dose (Dmean) (3.85 to 3.60 Gy), V5 (16.88% to 15.61%), and V20 (5.04% to 4.63%), along with improvements in the great vessels' Dmean and max dose (Dmax), and esophagus’ Dmax across all patients. Single-lesion patients saw consistent lung improvements, while multi-lesion patients experienced significant lung reductions and enhancements in great vessels' and esophagus’ metrics. In conclusion, both PlanVX and PlanEdge achieved treatment plans that met the dosimetric criteria defined by the RTOG guidelines. While Plan VX exhibited improved values in CI, HI, and GI, these findings reflect observed dosimetric differences rather than definitive evidence of clinical superiority. Further prospective studies are warranted to evaluate the clinical relevance of these differences.