Dosimetric comparison of two linear accelerators for lung cancer SBRT using IMRT dose delivery technique: VenusX vs. Edge
Authors:
Open Access
- 27 May 2025
- journal article
- research article
- Published by Springer Nature in European Journal of Medical Research
- Vol. 30 (1) , 1-12
Abstract
The VenusX and Edge accelerators are two commercially available systems used for lung stereotactic body radiation therapy (SBRT) with Intensity-Modulated Radiation Therapy (IMRT) techniques. A retrospective analysis was conducted on 40 lung cancer patients treated with the Edge accelerator. Treatment plans using both the Edge (PlanEdge) and VenusX (PlanVX) accelerators were generated and evaluated using various dosimetric metrics, employing statistical analyses to identify significant differences. For planned target volume (PTV), Plan VX outperformed PlanEdge across the entire cohort, achieving a higher D2 dose (76.84 vs 75.56 Gy, p = 0.005), and showing significant improvements in conformity index (0.84 vs 0.80), homogeneity index (0.50 vs 0.47), and gradient index (5.12 vs 5.62), all with p < 0.001. Plan VX also recorded a lower D2 cm (27.27 vs 27.87 Gy, p = 0.004). Subgroup analyses revealed significant enhancements in conformity index (CI), homogeneity index (HI), and gradient index (GI) for both single and multi-target lesion patients, with multi-target also seeing a notably lower D2 cm. regarding organs at risk (OARs), Plan VX significantly reduced lung mean dose (Dmean) (3.85 to 3.60 Gy), V5 (16.88% to 15.61%), and V20 (5.04% to 4.63%), along with improvements in the great vessels' Dmean and max dose (Dmax), and esophagus’ Dmax across all patients. Single-lesion patients saw consistent lung improvements, while multi-lesion patients experienced significant lung reductions and enhancements in great vessels' and esophagus’ metrics. In conclusion, both PlanVX and PlanEdge achieved treatment plans that met the dosimetric criteria defined by the RTOG guidelines. While Plan VX exhibited improved values in CI, HI, and GI, these findings reflect observed dosimetric differences rather than definitive evidence of clinical superiority. Further prospective studies are warranted to evaluate the clinical relevance of these differences.Keywords
Funding Information
- National Natural Science Foundation Young Investigator Grant Program (82403785)
This publication has 15 references indexed in Scilit:
- Characterization of a novel VenusX orthogonal dual‐layer multileaf collimatorJournal of Applied Clinical Medical Physics, 2024
- The impact of local control on widespread progression and survival in oligometastasis-directed SBRT: Results from a large international databaseRadiotherapy and Oncology, 2023
- Investigation of Halcyon multi‐leaf collimator model in Eclipse treatment planning system: A focus on the VMAT dose calculation with the Acuros XB algorithmJournal of Applied Clinical Medical Physics, 2022
- Treatment planning comparison of volumetric modulated arc therapy employing a dual-layer stacked multi-leaf collimator and helical tomotherapy for cervix uteriRadiation Oncology, 2020
- Radiation-induced lung injury patterns and the misdiagnosis after SBRT of lung cancerEuropean Journal of Radiology, 2019
- A systematic review and meta-analysis of stereotactic body radiation therapy versus surgery for patients with non–small cell lung cancerThe Journal of Thoracic and Cardiovascular Surgery, 2019
- A Randomized Phase 2 Study Comparing 2 Stereotactic Body Radiation Therapy Schedules for Medically Inoperable Patients With Stage I Peripheral Non-Small Cell Lung Cancer: NRG Oncology RTOG 0915 (NCCTG N0927)International Journal of Radiation Oncology - Biology - Physics (IJROBP), 2015
- Impact of collimator leaf width and treatment technique on stereotactic radiosurgery and radiotherapy plans for intra- and extracranial lesionsRadiation Oncology, 2009
- A dosimetric comparison of various multileaf collimatorsPhysics in Medicine & Biology, 2002
- A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: Application to the prostateInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1997