Michael Maisl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael Maisl has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Hans-Georg Herrmann
Core Facility for Correlative Microscopy and Tomography CoMiTo Faculty of Natural Sciences and Technology Saarland University Saarbruecken Germany
3 shared publications - Jonas Fell
Core Facility for Correlative Microscopy and Tomography CoMiTo Faculty of Natural Sciences and Technology Saarland University Saarbruecken Germany
2 shared publications - Anna Katharina Sambale
Leibniz-Institut für Polymerforschung Dresden e.V., Hohe Str. 6, 01069 Dresden, Germany
1 shared publication - Felix Wetzler
Lightweight Systems, Department of Materials Science, Campus E3 1, Saarland University, 66123 Saarbrücken, Germany
1 shared publication - Frank Mücklich
Department of Materials Science, Saarland University, 66123 Saarbrücken, Germany
1 shared publication Fraunhofer-Institute for Non-Destructive Testing (IZFP)
1 shared publication
Latest Publications
- Open Access
- 4 August 2023
- Published by MDPI AG in Journal of Imaging
- Vol. 9 (8) , 157
Target Design in SEM-Based Nano-CT and Its Influence on X-ray Imaging
Nano-computed tomography (nano-CT) based on scanning electron microscopy (SEM) is utilized for multimodal material characterization in one instrument. Since SEM-based CT uses geometrical magnification, X-ray targets can be adapted without any further changes to the system. This allows for designing targets with varying geometry and chemical composition to influence the X-ray focal spot, intensity and energy distribution with the aim to enhance the image quality. In this paper, three different target geometries with a varying volume are presented: bulk, foil and needle target. Based on the analyzed electron beam properties and X-ray beam path, the influence of the different target designs on X-ray imaging is investigated. With the obtained information, three targets for different applications are recommended. A platinum (Pt) bulk target tilted by 25° as an optimal combination of high photon flux and spatial resolution is used for fast CT scans and the investigation of high-absorbing or large sample volumes. To image low-absorbing materials, e.g., polymers or organic materials, a target material with a characteristic line energy right above the detector energy threshold is recommended. In the case of the observed system, we used a 30° tilted chromium (Cr) target, leading to a higher image contrast. To reach a maximum spatial resolution of about 100 nm, we recommend a tungsten (W) needle target with a tip diameter of about 100 nm.
- 4 August 2023
- Published by MDPI AG in Journal of Imaging
- Vol. 9 (8) , 157
Open AccessTarget Design in SEM-Based Nano-CT and Its Influence on X-ray Imaging
Nano-computed tomography (nano-CT) based on scanning electron microscopy (SEM) is utilized for multimodal material characterization in one instrument. Since SEM-based CT uses geometrical magnification, X-ray targets can be adapted without any further changes to the system. This allows for designing targets with varying geometry and chemical composition to influence the X-ray focal spot, intensity and energy distribution with the aim to enhance the image quality. In this paper, three different target geometries with a varying volume are presented: bulk, foil and needle target. Based on the analyzed electron beam properties and X-ray beam path, the influence of the different target designs on X-ray imaging is investigated. With the obtained information, three targets for different applications are recommended. A platinum (Pt) bulk target tilted by 25° as an optimal combination of high photon flux and spatial resolution is used for fast CT scans and the investigation of high-absorbing or large sample volumes. To image low-absorbing materials, e.g., polymers or organic materials, a target material with a characteristic line energy right above the detector energy threshold is recommended. In the case of the observed system, we used a 30° tilted chromium (Cr) target, leading to a higher image contrast. To reach a maximum spatial resolution of about 100 nm, we recommend a tungsten (W) needle target with a tip diameter of about 100 nm.
- Open Access
Characterisation and Modelling of Moisture Gradients in Polyamide 6
Polyamide 6 (PA6) is able to absorb water from the surrounding air and bond to it by forming hydrogen bonds between the carbonamide groups of its molecular chains. Diffusion processes cause locally different water concentrations in the (component) cross-section during the sorption process, resulting in locally different mechanical properties due to the water-induced plasticisation effect. However, the water content of PA6 is usually specified as an integral value, so no information about a local water distribution within a component is provided. This paper shows a method to characterise moisture distributions within PA6 samples using low-energy computer tomography (CT) techniques and comparing the reconstructed results with a developed finite elements (FE) modelling method based on Fick’s diffusion laws with concentration-dependent diffusion coefficients. For this purpose, the ageing of the samples at two different water bath temperatures as well as at different integral water contents are considered. The results obtained by CT reconstruction and FE modelling are in very good agreement, so that the concentration distributions by water sorption of PA6 calculated by FEM can be regarded as validated.
Open AccessCharacterisation and Modelling of Moisture Gradients in Polyamide 6
Polyamide 6 (PA6) is able to absorb water from the surrounding air and bond to it by forming hydrogen bonds between the carbonamide groups of its molecular chains. Diffusion processes cause locally different water concentrations in the (component) cross-section during the sorption process, resulting in locally different mechanical properties due to the water-induced plasticisation effect. However, the water content of PA6 is usually specified as an integral value, so no information about a local water distribution within a component is provided. This paper shows a method to characterise moisture distributions within PA6 samples using low-energy computer tomography (CT) techniques and comparing the reconstructed results with a developed finite elements (FE) modelling method based on Fick’s diffusion laws with concentration-dependent diffusion coefficients. For this purpose, the ageing of the samples at two different water bath temperatures as well as at different integral water contents are considered. The results obtained by CT reconstruction and FE modelling are in very good agreement, so that the concentration distributions by water sorption of PA6 calculated by FEM can be regarded as validated.
- Open Access
- 1 February 2020
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 25 (2)
Correlative Tomography – Combining x-ray nanotomography and FIB/SEM serial sectioning to analyze Al-Si cast alloys
The Largest Portal of Nondestructive Testing (NDT) Open Access Archive, Conference Proceedings, Journal Articles, News, Products, Services. Professional Networking, Exhibition, Forums, Jobs
- 1 February 2020
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 25 (2)
Open AccessCorrelative Tomography – Combining x-ray nanotomography and FIB/SEM serial sectioning to analyze Al-Si cast alloys
The Largest Portal of Nondestructive Testing (NDT) Open Access Archive, Conference Proceedings, Journal Articles, News, Products, Services. Professional Networking, Exhibition, Forums, Jobs