MMMichael Maisl

Michael Maisl

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Michael Maisl has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Target Design in SEM-Based Nano-CT and Its Influence on X-ray Imaging

    by Jonas Fell, Felix Wetzler, Michael Maisl, Hans-Georg Herrmann

    Nano-computed tomography (nano-CT) based on scanning electron microscopy (SEM) is utilized for multimodal material characterization in one instrument. Since SEM-based CT uses geometrical magnification, X-ray targets can be adapted without any further changes to the system. This allows for designing targets with varying geometry and chemical composition to influence the X-ray focal spot, intensity and energy distribution with the aim to enhance the image quality. In this paper, three different target geometries with a varying volume are presented: bulk, foil and needle target. Based on the analyzed electron beam properties and X-ray beam path, the influence of the different target designs on X-ray imaging is investigated. With the obtained information, three targets for different applications are recommended. A platinum (Pt) bulk target tilted by 25° as an optimal combination of high photon flux and spatial resolution is used for fast CT scans and the investigation of high-absorbing or large sample volumes. To image low-absorbing materials, e.g., polymers or organic materials, a target material with a characteristic line energy right above the detector energy threshold is recommended. In the case of the observed system, we used a 30° tilted chromium (Cr) target, leading to a higher image contrast. To reach a maximum spatial resolution of about 100 nm, we recommend a tungsten (W) needle target with a tip diameter of about 100 nm.


  • Open Access

    Characterisation and Modelling of Moisture Gradients in Polyamide 6

    by Anna Katharina Sambale, Michael Maisl, Hans-Georg Herrmann, Markus Stommel

    Polyamide 6 (PA6) is able to absorb water from the surrounding air and bond to it by forming hydrogen bonds between the carbonamide groups of its molecular chains. Diffusion processes cause locally different water concentrations in the (component) cross-section during the sorption process, resulting in locally different mechanical properties due to the water-induced plasticisation effect. However, the water content of PA6 is usually specified as an integral value, so no information about a local water distribution within a component is provided. This paper shows a method to characterise moisture distributions within PA6 samples using low-energy computer tomography (CT) techniques and comparing the reconstructed results with a developed finite elements (FE) modelling method based on Fick’s diffusion laws with concentration-dependent diffusion coefficients. For this purpose, the ageing of the samples at two different water bath temperatures as well as at different integral water contents are considered. The results obtained by CT reconstruction and FE modelling are in very good agreement, so that the concentration distributions by water sorption of PA6 calculated by FEM can be regarded as validated.


  • Open Access

    Correlative Tomography – Combining x-ray nanotomography and FIB/SEM serial sectioning to analyze Al-Si cast alloys

    by Michael Engstler, Saarland University, Jonas Fell, Michael Maisl, Hans-Georg Herrmann, Frank Mücklich, Fraunhofer-Institute for Non-Destructive Testing (IZFP)

    The Largest Portal of Nondestructive Testing (NDT) Open Access Archive, Conference Proceedings, Journal Articles, News, Products, Services. Professional Networking, Exhibition, Forums, Jobs